Download R-DPA96 A/AN
Transcript
Instruction Manual R-DPA96A R-DPA96 A/AN DIGITAL POWER ANALYSER BRIDEX Singapore Pte., Ltd Main Module MAIN CONTENTS 2 Module 1 kWh - kvarh - kVAh PRELIMINARY OPERATIONS ________________________________________________ 36 PRESENTATION ___________________________________________________________ 36 INSTALLATION_____________________________________________________________ 37 PROGRAMMING ___________________________________________________________ 38 TECHNICAL CHARACTERISTICS ____________________________________________ 42 GLOSSARY OF ABBREVIATIONS _____________________________________________42 Module 2 kWh - kvarh - kVAh Harmonics PRELIMINARY OPERATIONS ________________________________________________ 45 PRESENTATION ___________________________________________________________ 45 INSTALLATION _____________________________________________________________46 PROGRAMMING ___________________________________________________________ 47 OPERATION _______________________________________________________________ 51 TECHNICAL CHARACTERISTICS ____________________________________________ 52 GLOSSARY OF ABBREVIATIONS _____________________________________________52 Module 3 RS485 - JBUS/MODBUS DANGER AND WARNING ____________________________________________________4 PRELIMINARY OPERATIONS _________________________________________________4 PRESENTATION _____________________________________________________________5 INSTALLATION ______________________________________________________________5 PROGRAMMING ____________________________________________________________9 OPERATION _______________________________________________________________24 CONNECTION TEST FUNCTION ____________________________________________29 ASSISTANCE ______________________________________________________________32 TECHNICAL CHARACTERISTICS ____________________________________________33 GLOSSARY OF ABBREVIATIONS ____________________________________________35 PRELIMINARY OPERATIONS ________________________________________________55 GENERAL INFORMATION______________________________________________56 INSTALLATION_____________________________________________________________57 CONNECTION ________________________________________________________57 PROGRAMMING ___________________________________________________________58 COMMUNICATION ADDRESS __________________________________________59 COMMUNICATION SPEED _____________________________________________59 COMMUNICATION PARITY ____________________________________________60 COMMUNICATION STOP BIT __________________________________________60 COMMUNICATION _________________________________________________________61 THE STANDARD COMMUNICATIONS FRAME____________________________61 LIST OF PARAMETERS TO BE DISPLAYED ______________________________62 Table of values with allocated current and voltage winf-ding ratios on 2 words____________62 Address available with the Monitoring or Control/Command option______________________63 Instant value display _______________________________________________________________64 Table of values without allocated current and voltage winding ratios on 1 word ___________65 Alarm event log ___________________________________________________________________81 Table of current and voltage harmonics ______________________________________________82 Option recognition table____________________________________________________________85 RUDOLF - Ref. : 876 583 A Module 3 RS485 - JBUS/MODBUS LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED_________________86 RESET TO ZERO: ENERGY METERS AND MAX. VALUES _________________95 SAVED COMMAND ___________________________________________________96 PULSE METERS VALUES ______________________________________________96 DATE AND HOUR SETTINGS___________________________________________97 LAST 10 ALARMS EVENT LOG _________________________________________97 LAST 10 VOLTAGE DIPS EVENT LOG / SAG ____________________________111 LAST 10 VOLTAGE SURGE EVENT LOG / SWELL _______________________116 MINIMUM AND MAXIMUM INSTANTANEOUS VALUES ___________________121 LAST 10 VOLTAGE CUT-OFFS EVENT LOG / SAG _______________________125 MEAN POWER EVENT LOG___________________________________________127 MEAN VOLTAGE EVENT LOG _________________________________________127 MEAN FREQUENCY EVENT LOG ______________________________________127 TECHNICAL CHARACTERISTICS ___________________________________________128 GLOSSARY OF ABBREVIATIONS ___________________________________________128 Module 4 Outputs 0/4 - 20mA PRELIMINARY OPERATIONS _______________________________________________ 131 PRESENTATION __________________________________________________________ 131 INSTALLATION ___________________________________________________________ 132 PROGRAMMING__________________________________________________________ 133 TECHNICAL CHARACTERISTICS ___________________________________________ 138 GLOSSARY OF ABBREVIATIONS____________________________________________138 Module 5 2Inputs / 2 outputs PRELIMINARY OPERATIONS _______________________________________________ 141 PRESENTATION __________________________________________________________ 141 INSTALLATION ___________________________________________________________ 142 PROGRAMMING__________________________________________________________ 144 OPERATION ______________________________________________________________ 150 TECHNICAL CHARACTERISTICS ___________________________________________ 151 GLOSSARY OF ABBREVIATIONS____________________________________________151 Module 3+6 Profibus PLEASE CONSULT US Module 7 Memory PRELIMINARY OPERATIONS _______________________________________________ 153 PRESENTATION __________________________________________________________ 154 INSTALLATION ___________________________________________________________ 155 PROGRAMMING__________________________________________________________ 156 OPERATION ______________________________________________________________ 168 TECHNICAL CHARACTERISTICS ___________________________________________ 169 GLOSSARY OF ABBREVIATIONS____________________________________________168 RUDOLF - Ref. : 876 583 A 3 R-DPA96 A/AN DANGER AND WARNING This equipment must be mounted only by professionals. The manufacturer shall not be held responsible for failure to comply with the instructions in this manual. Risk of electrocution, burns or explosion • the device must be installed and serviced only by qualified personnel • prior to any work on or in the device, isolate the voltage inputs and auxiliary power supplies and short-circuit the secondary winding of all current transfromers (PTI RUDOLF) • always use an appropriate voltage detection device to confirm the absence of voltage • put all mechanisms, door and covers back in place before energising the device • always supply the device with the correct rated voltage Failure to take these precautions could cause serious injuries. PREMINARY OPERATIONS For personnel and product safety please read the contents of these operating instructions carefully before connecting. Check the following points as soon as you receive the R-DPA96 A/AN package: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product fitted with a pull-out terminal block, • operating instructions. Risk of damaging device Chek the following : • the voltage of the auxiliary power • the frequency of the distribution system (50 or 60 Hz) • the maximum voltage across the voltage-input terminals, (V1, V2, V3 and VN) 700 V AC phase-tophase or 400 V AC phase-to-neutral • a maximum current of 20 A on the current-input terminals (I1, I2 and I3) 4 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PRESENTATION INSTALLATION RECOMMANDATIONS 2 3 • avoid proximity to systems which generate electromagnetic interference, • avoid vibrations with accelerations in excess of 1 g for frequencies below 60 Hz. R-DPA96A 5 4 9 10 6 8 92 -+ 0,8 7 0,0 R-DPA96 A/AN 587 A 1 CUT-OUT DIAGRAMM 96 92 +- 0,8 4400 0,0 R-DPA96 A/AN 586 A 1. Key-pad with 6 dual-function keys (display or programming) 2. Backlit LCD display 3. Phase 4. Values 5. Unit 6. Activity indicator on the communication bus 7. Energy metering indication 8. Hour meter and energy display 9. Alarm relay 1 10. Alarm relay 2 20 60 96 R-DPA96 A/AN 584 A MOUNTING RUDOLF - Ref. : 876 583 A 5 R-DPA96 A/AN INSTALLATION CONNECTION OPTIONAL MODULES The maximum coupling torque for each screw is 0.4 Nm. Each CT’s secondary winding must be short-circuited when disconnecting the R-DPA96 A/AN is can be done automatically using one of Socomec’s catalogue products: the PTI. Please contact us for further information. The R-DPA96 A/AN can be fitted with optional modules: - JBUS/MODBUS communication; ref: R-MODULE 3: RS485 JBUS/MODBUS serial port in RTU mode with a speed from 2400 to 38400 baud. (User manual ref: CDR 27 028) - PROFIBUS-DP Communication; ref: R-MODULE 3+6: RS485 PROFIBUS-DP serial port with a speed from 9,600 baud to 1.5 Mbaud. (User manual ref: CDR 18 021) - Pulse outputs; ref: R-MODULE 1: 2 pulse outputs connected to the metering of energy in kWh, kvarh and KVAh (User manual ref: 876 584) - Harmonic and pulse outputs; ref: R-MODULE 2: 2 pulse outputs connected to the metering of energy in kWh, kvarh and KVAh. Analysis of the harmonic spectrum in current and voltage in rows and in phases up to row 25 (User manual ref: 876 585 - Analogue outputs; ref: R-MODULE 4: 2 analogue outputs 4/20 mA or 0/20 mA configurable for current, voltage, power and power factor. 2 modules can be installed, a maximum of 4 outputs (User manual ref: 876 586) - Inputs/Outputs; ref: R-MODULE 5: 2 outputs allocated for alarms, for voltage, current, power, power factor and THD, or remote control. 2 inputs for the metering of pulses or controlling position (User manual ref: 876 587). - Storage capability; ref: R-MODULE 7: Storage capability for storing mean active and reactive power, minimum and maximum instantaneous values, the last 10 alarms, troughs/overvoltages and power cuts according to EN50160 (User manual ref: 876 588). 1 Aux.: 110 … 400 V AC 120 … 350 V DC 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC 2 Fus.: S1 S2 S1 S2 S1 S2 R-DPA96 A/AN 286 C I1 I2 I3 2 V1 V2 V3 VN 1 R-DPA96 A S1 S2 S1 S2 S1 S2 S1 S2 I1 I2 I3 2 V1 V2 V3 VN 1 R-DPA96 A/AN 343 A R-DPA96 A/AN 453 B In R-DPA96 AN 6 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN INSTALLATION UNBALANCED THREE-PHASE NETWORK (4NBL) I1 I2 I3 S1 S2 S1 S2 S1 S2 In S1 S2 V1 V2 V3 VN UNBALANCED THREE-PHASE NETWORK (3NBL) The solution with 2 CTs with the 2nd and 3rd phase current calculated via vectoral summation, results in an 0.5% reduction in phase accuracy. AUX 2 I1 I2 I3 S1 S2 S1 S2 S1 S2 1 V1 V2 V3 VN AUX 2 2 S1 L1 (R ) P1 P1 R-DPA96 A/AN 272 1 S1 L2 (S) 2 S1 L3 (T) P1 N S1 L1 (R ) P1 V1 V2 V3 VN R-DPA96 A/AN I1 I2 I3 S1 S2 S1 S2 S1 S2 S1 AUX P1 L2 (S ) S1 L3 (T) P1 2 I1 I2 I3 S1 S2 S1 S2 S1 S2 1 V1 V2 V3 VN AUX 2 2 S1 L1 (R ) P1 1 S1 P1 L2 (S) 2 S1 R-DPA96 A/AN L3 (T) P1 N S1 L1 (R ) P1 2 Fus.: 110 … 400 V AC 120 … 350 V DC 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC L2 (S ) R-DPA96 A/AN 1 Aux.: S1 L3 (T) P1 I1 I2 I3 S1 S2 S1 S2 S1 S2 V1 V2 V3 VN AUX 2 1 2 S1 L1 (R ) R-DPA96 A/AN 278 P1 L2 (S ) P1 L3 (T) 1 Aux.: 2 Fus.: RUDOLF - Ref. : 876 583 A S1 110 … 400 V AC 120 … 350 V DC 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC 7 R-DPA96 A/AN INSTALLATION BALANCED THREE-PHASE NETWORK (3BL/4BL) TWO-PHASE NETWORK (2BL) I1 I2 I3 S1 S2 S1 S2 S1 S2 The solution using one CT, with the 3rd phase current calculated via vectoral summation, results in an 0.5% reduction in phase accuracy. I1 I2 I3 S1 S2 S1 S2 S1 S2 V1 V2 V3 VN AUX 2 1 V1 V2 V3 VN AUX 2 2 S1 1 L1 (R ) P1 L2 (S ) R-DPA96 A/AN 2 S1 1 Aux.: L1 (R ) P1 110 … 400 V AC 120 … 350 V DC R-DPA96 A/AN L2 (S ) L3 (T) I1 I2 I3 S1 S2 S1 S2 S1 S2 V1 V2 V3 VN 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC 2 Fus.: SINGLE-PHASE NETWORK (1BL) AUX I1 I2 I3 S1 S2 S1 S2 S1 S2 2 V1 V2 V3 VN AUX 1 2 2 1 2 S1 L1 (R ) R-DPA96 A/AN P1 L2 (S) S1 L3 (T) P1 N 1 Aux.: 2 Fus.: 110 … 400 V AC 120 … 350 V DC R-DPA96 A/AN 284 D L1 (R ) N 1 Aux.: 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC 2 Fus.: 110 … 400 V AC 120 … 350 V DC 12 … 48 V DC 0.5 A gG / BS 88 2A gG / 0.5 A class CC VOLTAGE TRANSFORMER V1 V2 V3 VN AUX 2 a a a 1 A A A L1 (R ) R-DPA96 A/AN L2 (S) L3 (T) 1 Aux.: 8 110 … 400 V AC 120 … 350 V DC 12 … 48 V DC RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING ACCES TO PROGRAMMING MODE COde 100 x1 3 sec x1 x1 x1 confirm RUDOLF - Ref. : 876 583 A 9 R-DPA96 A/AN PROGRAMMING NETWORK (Example : NET = 3NBL) x1 x x x x x x 1(1BL) 2 (2BL) 3 (3BL) 4 (3NBL) 5 (4BL) 6 (4 NBL) x1 confirm 10 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING CURRENT TRANSFORMERS (Example : CT = 1500 / 5A) x2 x1 x1 confirm RUDOLF - Ref. : 876 583 A 11 R-DPA96 A/AN PROGRAMMING NEUTRAL CURRENT TRANSFORMER DPA96 AN (Example : Ct In = 1500 / 5A) x2 x1 x1 confirm 12 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING VOLTAGE TRANSFOMERS (Example : Vt = YES) x1 x1 x1 confirm RUDOLF - Ref. : 876 583 A 13 R-DPA96 A/AN PROGRAMMING VOLTAGE TRANSFORMER PRIMARY (Example : PR = 20 000 V) x2 x2 x2 x1 x1 confirm 14 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING VOLTAGE TRANSFORMER SECONDARY (Example : SE = 110 V) x1 x 1 (110) x 2 (115) x 3 (120) x 4 (173) x 5 (190) x 6 (60) x 7 (100) x1 confirm RUDOLF - Ref. : 876 583 A 15 R-DPA96 A/AN PROGRAMMING INTEGRATION TIME (Example : tIME 4I = 20 min) x1 x 1 (20 min) x 2 (30 min) x 3 (60 min) x 4 (2 sec) x 5 (10 sec) x 6 (5 min) x 7 (8 min) x 8 (10 min) x 9 (15 min) x1 confirm 16 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING VOLTAGE INTEGRATION (Example : tIME U/V = 20 min) x1 x 1 (20 min) x 2 (30 min) x 3 (60 min) x 4 (10 sec) x 5 (5 min) x 6 (8 min) x 7 (10 min) x 8 (15 min) x1 confirm RUDOLF - Ref. : 876 583 A 17 R-DPA96 A/AN PROGRAMMING FREQUENCY INTEGRATION (Example : tIME F = 20 min) x1 x 1 (20 min) x 2 (30 min) x 3 (60 min) x 4 (10 sec) x 5 (5 min) x 6 (8 min) x 7 (10 min) x 8 (15 min) x1 confirm 18 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING INTEGRATION ACTIVE TIME POWERS (Example : tIME P/Q/S = 20 min) x1 x 1 (20 min) x 2 (30 min) x 3 (60 min) x 4 (10 sec) x 5 (5 min) x 6 (8 min) x 7 (10 min) x 8 (15 min) x1 confirm RUDOLF - Ref. : 876 583 A 19 R-DPA96 A/AN PROGRAMMING RESET TO ZERO (Example : rSET = Ea) x1 x 1 (MAX P+) x 2 (MAX P-) x 3 (MAX Q+) x 4 (MAX Q-) x 5 (MAX S) x 6 (HOUR) x 7 (EA+) x 8 (ER+) x 9 (ES) x 10 (EA-) x 11 (ER-) x 12 (MAX 4I) x 13 (MAX U) x 14 (MAX V) x 15 (MAX F) x1 x1 x1 confirm 20 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING HOUR RUN METER (Example : hour meter (for current) with start-up at 1000A) x1 x 1 (I) x 2 (U) x 3 (AUX) x1 confirm x1 x1 x1 x1 confirm RUDOLF - Ref. : 876 583 A 21 R-DPA96 A/AN PROGRAMMING BACKLIT LCD DISPLAY (Example : bACLIT = AUX) x1 x 1 (AUX) x 2 (I) x 3 (U) x1 confirm 22 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN PROGRAMMING SERIAL NUMBER (Example : SErl = 0320100) SOFTWARE VERSION TO QUIT PROGRAMMING x1 3 sec. RUDOLF - Ref. : 876 583 A 23 R-DPA96 A/AN OPERATION x1 DPA96A x2 x1 DPA96A x2 DPA96A x3 DPA96A x4 DPA96A DPA96A 24 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN OPERATION x1 DPA96A x2 DPA96A x3 DPA96A x4 DPA96A RUDOLF - Ref. : 876 583 A 25 R-DPA96 A/AN OPERATION 26 x1 DPA96A x5 DPA96A x2 DPA96A x6 DPA96A x3 DPA96A x7 DPA96A x4 DPA96A x8 DPA96A RUDOLF - Ref. : 876 583 A R-DPA96 A/AN OPERATION x9 DPA96A x 10 DPA96A x 11 DPA96A x 12 DPA96A RUDOLF - Ref. : 876 583 A 27 R-DPA96 A/AN OPERATION 28 x1 DPA96A x2 DPA96A x3 DPA96A RUDOLF - Ref. : 876 583 A R-DPA96 A/AN CONNECTION TEST FUNCTION During the test, the R-DPA96 A/AN must have current and voltage for each of the phases. In addition to this, the function recognises the PF of the installation as being between 0.6 > PF < 1. If the PF of the installation is not within this range, this function cannot be used. In 4 BL/3 BL/2BL/1 BL, the connection of the CTs is controlled only. In 4NBL and 3NBL the connection as a whole is controlled. Do check that these are the right conditions: Err 0 = no error Err 1 = CT phase 1 inverted Err 2 = CT phase 2 inverted Err 3 = CT phase 3 inverted Err 4 = V1 and V2 voltages inverted Err 5 = V2 and V3 voltages inverted Err 6 = V3 and V1 voltages inverted For the Err 1, Err 2 and Err 3, the modification can be performed automatically by the R-DPA96 A/AN or manually by correcting the current connections. For the Err 4, Err 5 and Err 6 the modification must be performed manually by correcting the voltage connections. DPA96A x1 3 sec. Example : tEsT Err 0 x1 3 sec. x1 3 sec. RUDOLF - Ref. : 876 583 A 29 R-DPA96 A/AN CONNECTION TEST FUNCTION Example : tEsT Err 2 x1 3 sec. x1 x1 x1 x1 3 sec 30 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN CONNECTION TEST FUNCTION > second test operation This menu is displayed if the product has already been tested. You can run a full test again as explained below.. x1 3 sec. x1 x1 RUDOLF - Ref. : 876 583 A 31 R-DPA96 A/AN ASSISTANCE • Device Switched off Check auxiliary supply • Backlight switched off Check backlight configuration in set up menu (p. 30) • Voltage = 0 Verify the connections • Current = 0 or incorrect Verify the connections Verify the configuration of CT’s in set up • Powers, power-factor and energies false Use the test connection function (p. 38) • Phases missing on Display Check the Network configuration (in set up menu) (p. 21) 32 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN TECHNICAL CHARACTERISTICS CASE Dimensions: Connection: IP index: Weight: 96 x 96 x 60 mm or 96 x 96 x 80 mm with all optional modules (DIN 43700) via 2.5 mm2 disconnectable terminals (voltage and others) and 6 mm2 fixed terminals (current) IP52 (front panel) and IP30 (case) 400 gr. DISPLAY Type : Backlit LCD display MEASUREMENTS Three-phase (3 or 4 wires), two-phase (2 wire) and single-phase networks VOLTAGE (TRMS) Direct measurement: from 18 to 700 V AC (phase/phase) from 10 to 404 V AC (phase/neutral) Measurement via PT: • Primary: up to 500 kV • Secondary: 60, 100, 110, 115, 120, 173 and 190 V AC Display and resolution from 0 to 500.0 kV Permanent overload: 760 V AC Update period: 1 second CURRENT (TRMS) Via CT with: • Primary: up to 10000 A • Secondary: 1 or 5 A Minimum measuring current 10 mA Input consumption: < 0.3 VA Display: from 0 to 11 kA (1.1 times the primary value) permanent overload: 10 A intermittent overload: 10 In / 1 second Update period: 1 second Maximum ratio KI x KU: 10 000 000 POWER Total: 0 to 8000 MW/Mvar/MVA Update period: 1 second FREQUENCY from 45,0 to 65,0 Hz Update period: 1 second ENERGY / MEASUREMENT ACCURACY Current: Voltage: Power: Power factor: Frequency: Active energy metering: Reactive energy metering: 0.2 % from 10 to 110 % / In 0.2 % from 140 to 700 V AC 0.5 % of full scale (-90° à + 90°) 0.5 % for 0.5 < FP < 1 0.1 % from 45 to 65 Hz ± 0.5 % from 0.02 to 1,2 In with PF = 0.5 L or 0.8 C (class 0.5S IEC 62053-22) ± 2% from 0.1 to 1,2 In with sinϕ = 0.5 L or C (class 2 IEC 62053-23) AUXILIARY SUPPLY 110 to 440 V AC 50/60 Hz 120 to 350 V DC 12 to 48 V DC Consumption: RUDOLF - Ref. : 876 583 A ± 10 % ± 20 % -6 % / + 20 % < 10 VA 33 R-DPA96 A/AN TECHNICAL CHARACTERISTICS OPERATING CONDITIONS Operating temperature: Storage temperature: Relative humidity: -10° to + 55°C (14° to 131°F) -20° to + 85°C (-4° to 158°F) 95 % CE MARKING The R-DPA96 A/AN A40/A41 complies with : • The requirements of the European directive on electromagnetic compatibility (EMC) no. 89/336/CEE dated 3 May 1989, modified by directive no. 92/31/CEE dated 28 April 1992 and by directive no. 93/68/CEE dated 22 July 1993. • Low voltage directive no. 73/23/CEE dated 19 February 1973, modified by directive no. 93/68/CEE dated 22 July 1993. ELECTROMAGNETIC COMPATIBILITY Immunity to electrostatic discharges: Immunity to radiated radio-frequency fields: Immunity to electrical fast transients/bursts: Immunity to impulse waves: Immunity to conducted disturbances: Immunity to power frequency magnetic fields: Conducted and radiated emissions: Immunity to voltage dips and short interruptions: IEC 61000-4-2 - Level III IEC 61000-4-3 - Level III IEC 61000-4-4 - Level IV IEC 61000-4-5 - Level IV IEC 61000-4-6 - Level III IEC 61000-4-8 - Level IV IEC 61000-6-4 - Class B IEC 61000-4-11 CLIMATE Operating-temperature range: Storage temperature range: Humidity: Saling fog: IEC 60068-2-1/IEC 60068-2-2 -10 °C to +55 °C IEC 60068-2-1/IEC 60068-2-2 -20 °C to +85 °C IEC 60068-2-30 - 95 % IEC 60068-2-52 - 2,5 % NaCl MECHANICAL CHARACTERISTICS Vibration from 10 to 50 Hz : IEC 60068-2-6 - 2 g INSULATION Installation category: Degree of pollution: Rated impulse withstand voltage: Front face: Electric security: III (480VAC ph/ph) 2 IEC 60947-1 - V imp: 4 kV Classe II IEC 61010-1 CERTIFICATION UL 61010-1 34 N° file : E257746 RUDOLF - Ref. : 876 583 A R-DPA96 A/AN GLOSSARY OF ABBREVIATIONS nEt 4NBL 4BL 3NBL 3BL 2BL 1BL Ct Ct In Ut Ut PR Ut SE MAX AVG tIME 4I tIME U tIME F tIME P/Q/S rSET MAX P+ MAX PMAX Q+ MAX QMAX S HOUr EA+ EAER+ ERES HOUr AUX bACLIt SErI SOFt PF THD I THD In THD U THD V RUDOLF - Ref. : 876 583 A Network type Unbalanced three-phase network, 4 wires with 3 or 4 TC Balanced three-phase network, 4 wires with 1 TC Unbalanced three-phase network, 3 wires with 2 or 3 TC Balanced three-phase network, 3 wires with 1 TC Two-phase network, 2 fils avec 1 TC Single-phase network, 2 fils avec 1 TC Current transfromers Neutral current transformer Voltage transformer Voltage transformer primary Voltage transformer secondary Maximum mean values Average value Integration times for mean and maximum current values Integration times for mean and maximum voltage values Integration times for mean and maximum frequency values Integration times for mean and maximum power values Reset Active power maximum positive mean value Active power maximum negative mean value Reactive power maximum positive mean value Reactive power maximum negative mean value_A faire valider Effective power maximum mean value Hour run meter Positive active power (+kWh) Negative active power (-kWh) Positive reactive power (+kvarh) Negative reactive power (-kvarh) Apparent power (-kVAh) Hour meter start-up (U or I or Aux. condition) Auxiliary supply LCD start-up (U or I or Aux. Condition) Serial number Software version Power factor Current harmonic distortion rate Neutral current distortion rate Phase-to-phase voltage distortion rate Phase-to-neutral voltage distortion rate Hour run meter 35 R-DPA96 A/AN - R-Module 1 2 Outputs kWh - kvarh - KVAh PRELIMINARY OPERATIONS When the package containing the optional module is received, the following points must be checked: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product, • the operating instructions. 36 PRESENTATION This optional module must be connected to the RDPA96 A/AN (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). This module allows the combining with the metering of active (0 to 99 999 999 kWh), reactive (0 to 99 999 999 kvarh) and apparent energy (0 to 99 999 999 kVAh) of two pulse outputs that can be configured according to value (0.1, 1, 10, 100 kWh, kvarh or kVAh and 1 or 10 MWh, Mvarh and MVAh) and duration (100 ms to 900 ms). RUDOLF - Ref. :876 584 A R-DPA96 A/AN - R-Module 1 ( kWh - kvarh - kVah) INSTALLATION CONNECTION This R-DPA96 A/AN must be switched off. 2 Fix the module R-DPA96 343 R-DPA96 342 A 1 3 4 Follow indications when connecting the ter minal. Switch on voltage supply. OUT2 3 4 2 1 R-DPA96 344 OUT1 37 37 RUDOLF - Ref. :876 584 A R-DPA96 A/AN - R-Module 1 ( kWh - kvarh - kVah) PROGRAMMING Previous menu p 39 p 40 p 41 p 42 Following menu RUDOLF - Ref. :876 584 A 38 R-DPA96 A/AN - R-Module 1 ( kWh - kvarh - kVah) PROGRAMMING PULSE OUTPUT N°1TYPE - Example : TYPE = ER (kvarh) x1 x 1 (ER) x 2 (ES) x 3 (EA-) x 4 (ER-) x 5 (EA) x1 confirm 39 RUDOLF - Ref. :876 584 A R-DPA96 A/AN - R-Module 1 (kWh - kvarh - kVAh) PROGRAMMING PULSE OUTPUT N°1 RATE - Exemple : VAL = 100 (1 = 100 kvarh) x1 x 1 (100) x 2 (1000) x 3 (10000) x 4 (0.1) x 5 (1) x 6 (10) x1 confirm RUDOLF - Ref. :876 584 A 40 R-DPA96 A/AN - R-Module 1 ( kWh - kvarh - kVah) PROGRAMMING PULSE OUTPUT N°1DURATIONS - Example : DUR = 200 ms x1 x 1 (200 ms) x 2 (300 ms) x 3 (400 ms) x 4 (500 ms) x 5 (600 ms) x 6 (700 ms) x 7 (800 ms) x 8 (900 ms) x1 confirm 41 RUDOLF - Ref. :876 584 A R-DPA96 A/AN - R-MODULE 1 (kWh - kvarh - kVAh) PROGRAMMING - TECHNICAL CHARACTERISTICS GLOSSARY OF ABBREVIATIONS PULSE OUTPUT N°2 PROGRAMMING Proceed as for output n°1 TECHNICAL CARACTERISTICS Reed relays N° of operations Galvanic insulation (AC insulation voltage) Certification UL 61010-1 max. 100 V DC - 0.5 A - 10 VA ≤ 108 2.5 kV N° file : E25 7746 GLOSSARY OF ABBREVIATIONS Out 1… Out 2 TYPE EA+ ER+ ES EAER- RUDOLF - Ref. :876 584 A Pulse output 1 and 2 Pulse output allocation Positive active power (kWh+) Positive reactive power(kvarh+) Effective power(kVAh) Negative active power(- kWh) Negative reactive power (- kvarh) VAL DUR THD H03 … H25 Pulse value Pulse duration Harmonic distortion rate Harmonic numbers 3 to 25 42 43 RUDOLF- Ref. :876 584 A RUDOLF - Ref. :876 584 A 44 R-DPA96 A/AN - R-Module 2 2 Outputs kWh - kvarh - KVAh, Harmonics PRELIMINARY OPERATIONS Check the following points as soon as you receive the module option package: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product, • the operating instructions. PRESENTATION This optional module must be connected to the DPA96 A/AN (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). This module allows the combining with the metering of active +/- (0 to 99 999 999 kWh), reactive +/- (0 to 99 999 999 kvarh) and apparent energy (0 to 99 999 999 kVAh) of two pulse outputs that can be configured according to value (0.1, 1, 10, 100 kWh, kvarh or kVAh and 1 or 10 MWh, Mvarh and MVAh) and duration (100 ms to 900 ms). Display of the harmonic percentage per row for 3I, In, 3U, 3V up to row 25 (row 15 for DPA96 and DPA96A , software version 1.03) as well as thd 3I, thd In, thd 3U and thd 3V up to row 51. 45 R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) INSTALLATION CONNECTION This DPA96 A/AN must be switched off. 1 Fix the module DPA96 343 A DPA96 342 A 2 3 4 Follow indications when connecting the terminal. Switch on voltage supply. OUT2 3 4 2 1 DPA96 344 A OUT1 46 RUDOLF- Ref. : 876 585 A R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) PROGRAMMING Previous menu p 48 p 49 p 50 p 50 Following menu RUDOLF- Ref. : 876 585 A 47 R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) PROGRAMMING PULSE OUTPUT N°1 TYPE - Example : TYPE = ER+ (kvarh) x1 x 1 (ER+) x 2 (ES) x 3 (EA-) x 4 (ER-) x 5 (EA+) x1 confirm 48 RUDOLF- Ref. : 876 585 A R-DPA96 A/AN - R-MODULE 2 (kWh-kvarh-kVAh, Harmonics) PROGRAMMING PULSE OUTPUT N°1 RATE - Example : VAL = 100 (1 = 100 kvarh) x1 x 1 (100) x 2 (1000) x 3 (10000) x 4 (0.1) x 5 (1) x 6 (10) x1 confirm RUDOLF- Ref. : 876 585 A 49 R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) PROGRAMMING PULSE OUTPUT N°1 DURATIONS - Example : DUR = 200 ms x1 x 1 (200 ms) x 2 (300 ms) x 3 (400 ms) x 4 (500 ms) x 5 (600 ms) x 6 (700 ms) x 7 (800 ms) x 8 (900 ms) x 9 (100 ms) x1 confirm PULSE OUTPUT N°2 PROGRAMMING Proceed as for output n°1 50 RUDOLF- Ref. : 876 585 A R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) OPERATION Display of the total distorsion (thd) up to row 51 and the harmonics in current (HI) and voltage (HU and HV) per phase up to row 25. x1 DPA96A x4 DPA96A x2 DPA96A x 13 DPA96A x3 DPA96A x 21 DPA96A RUDOLF- Ref. : 876 585 A 51 R-DPA96 A/AN - R-Module 2 (kWh - kvarh - KVAh, Harmonics) TECHNICAL CHARACTERISTICS Harmonics Updating of % Accuracy Minimum value displayed Pulse outputs Reed relays N° of operations Galvanic insulation (AC insulation voltages) Certification UL 61010-1 1 sec ± 0.5 point 1.6 % max. 100 V DC - 0.5 A - 10 VA ≤ 108 2.5 kV N° file : E25 7746 GLOSSARY OF ABBREVIATIONS Out 1… Out 2 TYPE EA+ ER+ ES EAER- 52 Pulse output 1 and 2 Pulse output allocation Positive active power (kWh+) Positive reactive power(kvarh+) Effective power(kVAh) Negative active power(- kWh) Negative reactive power (- kvarh) VAL DUR THD H03 … H25 Pulse value Pulse duration Total harmonic distortion Harmonic numbers 3 to 25 RUDOLF- Ref. : 876 585 A SOCOMEC - Réf. : 876 585 A 53 54 SOCOMEC - Réf. : 876 585 A R-DPA96 A/AN - R-Module 3 ON 1 RS485 – JBUS/MODBUS® M O C PRELIMINARY OPERATIONS For personnel and product safety please read the contents of these operating instructions carefully before connecting. Check the following points as soon as you receive the R-DPA96 A/AN package: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product and the operating instructions. 55 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) GENERAL INFORMATION FUNCTIONS GENERAL POINTS The optional IP Communication module must be connected to the R-DPA96 A/AN (réf. : 4825 0A40, 4825 0A41, 4825 1A40, 4525 1A41). It provides an RS485 serial link (2 or 3 wires) with JBUS/MODBUS® protocol for the use of R-DPA96 A/AN from a PC or PLC. For a standard configuration, an RS 485 link is used to connect up to 31 R-DPA96 with a PC or a PLC over a distance of 1500 metres, using JBUS/MODBUS© protocol. 1500 M R = 120 N 1 N 2 N n R = 120 R-DPA96 109 C GB Programmable controllers Other systems 1500 M R = 120 N 1 1500 M 0+-+0 repetor RS485 N n R = 120 R-DPA96 110 C GB Programmable controllers Other systems Recommendations: You should use a shielded twisted pair (LIYCY type). In a disturbed environment or large network (in terms of length) we recommend the use of 2 shielded pairs (type LIYCY-CY). In this case, one pair is used for the + and the –, and another pair, where the 2 wires are short-circuited, for the 0 V. A repeater (1 channel) or an arrestor (4 channels) should be used if you intend to exceed the distance (1500 m) and/or maximum number (31) of R-DPA96. Please contact us for more information. 56 NB : A 120 ohm resistance (found on the additional module) must be fixed at both ends of the link. Other solutions are available (modem, optical fibre, etc.). Please contact us. RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) INSTALLATION CONNECTION The module is fitted onto the back of the R-DPA96 A/AN in one of the 4 positions provided. The R-DPA96 A/AN must be switched off 2 Fix the module in one of the four positions. R-DPA96 342 A R-DPA96 343 A 1 3 4 1 + Ω R-DPA96 347 A O N 1 - O R N = 1 2 0 0V Follow indications when connecting the terminal. Switch on voltage supply. RUDOLF - Ref. : CDR 27 028_gb 57 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) PROGRAMMING Previous menu p.59 p.59 p.60 p.60 Following menu 58 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) PROGRAMMATION COMMUNICATION ADDRESS > Example : COM ADR = 7 x3 x2 x1 confirm COMMUNICATION SPEED > Example : BDS = 19200 bauds x1 x1 x1 confirm RUDOLF - Ref. : CDR 27 028_gb 59 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) PROGRAMMATION COMMUNICATION PARITY > Example : PAR = Even x1 x 1 (Odd) x 2 (Even) x 3 (No) x1 confirm COMMUNICATION STOP BIT > Example : STOP = 2 x1 x 1 (2 bits) x 2 (1 bits) x1 confirm 60 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - RS485 - JBUS/MODBUS® COMMUNICATION The JBUS/MODBUS® used by the R-DPA96 A/AN The mode of communication is the RTU (Remote involves a dialogue using a master-slave hierarchical Terminal Unit) using hexadecimal characters of at least 8 bits. structure. There are two possible dialogues: • the master communicates with a slave (R-DPA96) and waits for its reply • the master communicates with all the slaves (RDPA96) without waiting for their reply. THE STANDARD COMMUNICATIONS FRAME The standard communications frame consists of: Slave address Function code Address According to the JBUS/MODBUS® protocol, transmission time must be less than 3 silences, i.e. the emission time of 3 characters so that the message is processed by the R-DPA96. To correctly use information, the following functions are important: 3 : to read n words (maximum 128). 6 : to write one word. 8 : to diagnose exchanges between the master and the slave via meters 1, 3, 4, 5 and 6. 16 : to write n words (maximum 128). RUDOLF - Ref. : CDR 27 028_gb Data CRC 16 NB: When selecting slave address 0, a message is sent to all the instruments present on the network (only for functions 6 and 16). Comment : The response time (time out question/answer) is 250 ms maximum 61 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Table of values with allocated current and voltage winf-ding ratios on 2 words Decimal Hexa. Number Text address address of words 768 300 2 Phase 1 current 770 302 2 Phase 2 current 772 304 2 Phase 3 current 774 306 2 Neutral current 776 308 2 Phase to phase voltage U12 778 30A 2 Phase to phase voltage U23 780 30C 2 Phase to phase voltage U31 782 30E 2 Phase to neutral voltage phase 1 784 310 2 Phase to neutral voltage phase 2 786 312 2 Phase to neutral voltage phase 3 788 314 2 Frequency 790 316 2 Σ active power +/792 318 2 Σ reactive power +/794 31A 2 Σ apparent power 796 31C 2 Σ power factor -: leading and +: lagging 798 31E 2 Active power phase 1 +/800 320 2 Active power phase 2 +/802 322 2 Active power phase 3 +/804 324 2 Reactive power phase 1 +/806 326 2 Reactive power phase 2 +/808 328 2 Reactive power phase 3 +/810 32A 2 Apparent power phase 1 812 32C 2 Apparent power phase 2 814 32E 2 Apparent power phase 3 816 330 2 Power factor phase 1 -: leading and +: lagging 818 332 2 Power factor phase 2 -: leading and +: lagging 820 334 2 Power factor phase 3 -: leading and +: lagging 822 336 2 avg I1 824 338 2 avg I2 826 33A 2 avg I3 828 33C 2 avg Σ active power + 830 33E 2 avg Σ active power 832 340 2 avg Σ reactive power + 834 342 2 avg Σ reactive power 836 344 2 avg Σ apparent power 838 346 2 max/avg I1 840 348 2 max/avg I2 842 34A 2 max/avg I3 844 34C 2 max/avg Σ active power + 846 34E 2 max/avg Σ active power 848 350 2 max/avg Σ reactive power + 850 352 2 max/avg Σ reactive power 852 354 2 max/avg Σ apparent power 854 356 2 hour meter 856 358 2 Active energy + 858 35A 2 Reactive energy + 860 35C 2 Apparent energy 862 35E 2 Active energy 864 360 2 Reactive energy - 62 Unit mA mA mA mA V/100 V/100 V/100 V/100 V/100 V/100 Hz/100 kW/100 kvar/100 kVA/100 0.001 kW/100 kW/100 kW/100 kvar/100 kvar/100 kvar/100 kVA/100 kVA/100 kVA/100 0.001 0.001 0.001 mA mA mA kW/100 kW/100 kvar/100 kvar/100 kVA/100 mA mA mA kW/100 kW/100 kvar/100 kvar/100 kVA/100 1/100 h kWh kvarh kVAh kWh kvarh RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Address available with the Monitoring or Control/Command option Decimal Hexa. Number Text address address of words 866 362 2 Input pulse meter 1 868 364 2 Input pulse meter 2 870 366 2 Number of impulse meters 872 368 2 Current alarm : 0 : no alarm 1:I 2:U 3: ΣP+ 4: ΣQ+ 5: ΣS 6: F 7 : ΣPFL 8 : thd I 9 : thd U 10 : In 11 : HOUr 12 : V 13 : thd In 14 : thd V 15 : ΣP16 : ΣQ17 : Σ PFC 874 36A 2 Current overrun : 0 : no alarm 1:I 2:U 3: ΣP+ 4: ΣQ+ 5: ΣS 6: F 7 : ΣPFL 8 : thd I 9 : thd U 10 : In 11 : HOUr 12 : V 13 : thd In 14 : thd V 15 : ΣP16 : ΣQ17 : Σ PFC 876 36C 2 Number of inputs-outputs Low-order: number of inputs High-order: number of outputs 878 36E 2 Status of inputs-outputs 0 : status input 1 (0 = open, 1 = closed) bit 1 : status input 2 (0 = open, 1 = closed) bit 2 : status input 3 (0 = open, 1 = closed) bit 3 : status input 4 (0 = open, 1 = closed) bit 4 : status input 5 (0 = open, 1 = closed) bit 5 : status input 6 (0 = open, 1 = closed) bit 16 : status output 1 (0 = open, 1 = closed) bit 17 : status output 2 (0 = open, 1 = closed) bit 18 : status output 3 (0 = open, 1 = closed) bit 19 : status output 4 (0 = open, 1 = closed) bit 20 : status output 5 (0 = open, 1 = closed) bit 21 : status output 6 (0 = open, 1 = closed) RUDOLF - Ref. : CDR 27 028_gb Unit – – – – – – 63 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Instant value display Decimal Hexa. address address 880 370 882 372 884 374 886 376 888 378 890 37A 892 37C 894 37E 896 380 898 382 900 384 902 386 904 388 906 38A 908 38C 910 38E 912 390 914 392 916 394 918 396 920 398 922 39A 924 39C Number of words 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Text Unit System value for current System value for phase-to-phase voltage System value for phase-to-neutral voltage avg U12 avg U23 avg U31 avg V1 avg V2 avg V3 avg F max/avg U12 max/avg U23 max/avg U31 max/avg V1 max/avg V2 max/avg V3 max/avg F avg In max/avg In Mean positive active power between 2 signals Mean negative active power between 2 signals Mean positive reactive power between 2 signals Mean negative reactive power between 2 signals mA V/100 V/100 V/100 V/100 V/100 V/100 V/100 V/100 Hz/100 V/100 V/100 V/100 V/100 V/100 V/100 Hz/100 mA mA 0.1 kW 0.1 kW 0.1 kvar 0.1 kvar Zone size: 158 words (decimal) or 9E (hexadecimal). Example: To display all the values for R-DPA96 number 5 in one inquiry, the following frame should be sent: 64 Slave Function High-order address Low-order address High-order word n° Low-order word n° CRC 16 05 03 03 00 00 9E C5A7 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Table of values without allocated current and voltage winding ratios on 1 word Decimal address 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 Hexa. address 700 701 702 703 704 705 706 707 708 709 70A 70B 70C 70D 70E Number of words 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 70F 710 711 712 713 714 715 716 717 718 1 1 1 1 1 1 1 1 1 1 1817 719 1 1818 71A 1 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 71B 71C 71D 71E 71F 720 721 722 723 724 725 726 727 728 729 72A 72B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Phase 1 current Phase 2 current Phase 3 current Neutral current Phase to phase voltage U12 Phase to phase voltage U23 Phase to phase voltage U31 Phase to neutral voltage phase 1 Phase to neutral voltage phase 2 Phase to neutral voltage phase 3 Frequency Σ active power +/Σ reactive power +/Σ apparent power +/Σ power factor L/C -: leading and +: lagging Active power phase 1 +/Active power phase 2 +/Active power phase 3 +/Reactive power phase 1 +/Reactive power phase 2 +/Reactive power phase 3 +/Apparent power phase 1 Apparent power phase 2 Apparent power phase 3 Power factor phase 1 L/C -: leading and +: lagging Power factor phase 2 L/C -: leading and +: lagging Power factor phase 3 L/C -: leading and +: lagging avg I1 avg I2 avg I3 avg Σ active power + avg Σ active power avg Σ reactive power + avg Σ reactive power avg Σ apparent power max/avg I1 max/avg I2 max/avg I3 max/avg Σ active power + max/avg Σ active power max/avg Σ reactive power + max/avg Σ reactive power max/avg Σ apparent power Active energy + < 10000 mA mA mA mA V/10 V/10 V/10 V/10 V/10 V/10 Hz/100 kW/100 kvar/100 kVA/100 0.001 kW/100 kW/100 kW/100 kvar/100 kvar/100 kvar/100 kVA/100 kVA/100 kVA/100 0.001 0.001 0.001 mA mA mA kW/100 kW/100 kvar/100 kvar/100 kVA/100 mA mA mA kW/100 kW/100 kvar/100 kvar/100 kVA/100 kWh 65 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Decimal address 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 66 Hexa. address 72C 72D 72E 72F 730 731 732 733 734 735 736 737 738 739 73A 73B 73C 73D 73E 73F 740 741 742 743 744 745 746 747 748 749 74A 74B 74C 74D 74E 74F 750 751 752 753 754 755 756 757 758 759 75A 75B Number of words 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Text Unit Active energy + > 10000 Reactive energy + < 10000 Reactive energy + > 10000 Apparent energy < 10000 Apparent energy > 10000 Active energy - < 10000 Active energy - >10000 Reactive energy - < 10000 Reactive energy - > 10000 Input pulse meter 1 < 10000 Input pulse meter 1 > 10000 Input pulse meter 2 < 10000 Input pulse meter 2 > 10000 Input pulse meter 3 < 10000 Input pulse meter 3 > 10000 Input pulse meter 4 < 10000 Input pulse meter 4 > 10000 Input pulse meter 5 < 10000 Input pulse meter 5 > 10000 Input pulse meter 6 < 10000 Input pulse meter 6 > 10000 Average value of currents Average value of phase to phase voltages Average value of phase to neutral voltages avg U12 avg U23 avg U31 avg V1 avg V2 avg V3 avg F max/avg U12 max/avg U23 max/avg U31 max/avg V1 max/avg V2 max/avg V3 max/avg F thd I1 thd I2 thd I3 thd In thd U12 thd U23 thd U31 thd V1 thd V2 thd V3 kWh kvarh kvarh kVAh kVAh kWh kWh kvarh kvarh – – – – – – – – – – – – mA V/10 V/10 V/10 V/10 V/10 V/10 V/10 V/10 Hz/100 V/10 V/10 V/10 V/10 V/10 V/10 Hz/100 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Decimal address 1884 1885 1886 1887 1888 1889 1890 1891 Hexa. address 75C 75D 75E 75F 760 761 762 763 Number of words 1 1 1 1 1 1 1 1 Text Unit Mean positive active power between 2 signals Mean negative active power between 2 signals Mean positive reactive power between 2 signals Mean negative reactive power between 2 signals Reserved Reserved Average values In In max 0.1 W 0.1 W 0.1 var 0.1 var – – mA mA Zone size: 100 words (decimal) or 64 (hexadecimal). Example : To read 177 645 kWh, the following message should be sent : Slave Function High-order address Low-order address High-order word n° Low-order word n° CRC 16 05 03 07 2B 00 02 B4F3 R-DPA96 A40/A41 reply: Slave Function Number of bytes Word 1 < 10000 Word 2 > 10000 CRC 16 05 03 04 IDDD 11 6FD6 7645 17 Example: To display all the values for R-DPA96 number 5 in one inquiry, the following frame should be sent: Slave Function High-order address Low-order address High-order word n° Low-order word n° CRC 16 05 03 07 00 00 64 44D1 RUDOLF - Ref. : CDR 27 028_gb 67 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log 68 Decimal address 1280 Hexa. address 500 Number of words 1 1281 1283 501 503 2 1 Text Unit Current alarm OUT 1 lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 1 lower threshold value Current alarm OUT 1 upper threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 – – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address Hexa. address Number of words 1284 1286 1287 504 506 507 2 1 1 1288 1290 508 50A 2 1 RUDOLF - Ref. : CDR 27 028_gb Text 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 1 upper threshold value Duration Alarm 1 OUT 1 ower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 1 OUT 1ower threshold value Alarm 1 OUT 1 threshold value: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ Unit – s. – – – 69 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 70 Hexa. address Number of words 1291 1293 1294 50B 50D 50E 2 1 1 1295 50F 2 Text Unit 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 1 OUT 1 upper threshold value Duration Alarm 2 OUT 1 lower threshold 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 2 OUT 1 lower threshold value – s. – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1297 Hexa. address 511 Number of words 1 1298 1300 1301 512 514 515 2 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Alarm 2 OUT 1 threshold value: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 2 OUT 1 upper threshold value Duration Alarm 3 OUT 1 lower threshold 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR – – s. – 71 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 72 Hexa. address Number of words 1302 1304 516 518 2 1 1305 1307 1308 519 51B 51C 2 1 1 Text Unit 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 3 OUT 1ower threshold value Alarm 3 OUT 1 threshold value: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 3 OUT 1 upper threshold value Duration Current alarm OUT 2 lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ – – – s. – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address Hexa. address Number of words 1309 1311 51D 51F 2 1 1312 520 2 RUDOLF - Ref. : CDR 27 028_gb Text 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 2 lower threshold value Current alarm OUT 2 upper threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 2 upper threshold value Unit – – – 73 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) 74 Decimal address 1314 1315 Hexa. address 522 523 Number of words 1 1 1316 1318 524 526 2 1 Text Unit Duration Alarm 1 OUT 2 lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 1 OUT 2 lower threshold value : Alarm 1 OUT 2 upper threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR s. – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address Hexa. address Number of words 1319 1321 1322 527 529 52A 2 1 1 1323 1325 52B 52D 2 1 RUDOLF - Ref. : CDR 27 028_gb Text 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 1 OUT Duration Alarm 2 OUT 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 2 OUT Alarm 2 OUT 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ Unit 2 upper threshold value – s. 2 lower threshold: 2 lower threshold value 2 upper threshold: – – 75 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1326 1328 1329 76 Hexa. address 52E 530 531 Number of words 2 1 1 Text Unit 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 2 OUT 2 upper threshold value Duration Alarm 3 OUT 2 lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC – s RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1330 1332 Hexa. address 532 534 Number of words 2 1 1333 1335 1336 1337 535 537 538 539 2 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Alarm 3 OUT 2 lower threshold value Alarm 3 OUT 2 upper threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Alarm 3 OUT 2 upper threshold value Duration Status inputs 1 and 2 plus 3, 4, 5, 6 Current alarm OUT 3 lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 – – s. – 77 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 78 Hexa. address Number of words 1338 1340 53A 53C 2 1 1341 1343 1344 53D 53F 540 2 1 1 Text 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm Duration Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 Unit OUT 3 lower threshold value OUT 3 upper threshold: OUT 3 upper threshold value – – – – s. OUT 4 lower threshold : RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1345 1347 Hexa. address 541 543 RUDOLF - Ref. : CDR 27 028_gb Number of words 2 1 Text 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 4 lower threshold value Current alarm OUT 4 upper threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Unit – – – 79 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) 80 Decimal address 1348 1350 1351 Hexa. address 544 546 547 Number of words 2 1 1 1352 1354 548 54A 2 1 Text Current alarm Duration Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 Unit OUT 4 upper threshold value OUT 5 lower threshold: OUT 5 lower threshold value OUT 5 upper threshold: – s. – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1355 1357 1358 1359 1361 Hexa. address 54B 54D 54E 54F 551 RUDOLF - Ref. : CDR 27 028_gb Number of words 2 1 1 2 1 Text 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm Duration Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm Current alarm 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ Unit OUT 5 upper threshold value – s. OUT 6 lower threshold : – OUT 6 lower threshold value OUT 6 upper threshold: – – 81 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Alarm event log (continued) Decimal address 1362 Hexa. address 552 Number of words 2 Text Unit 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Current alarm OUT 6 upper threshold value – Text Unit thd I1 thd I2 thd I3 thd In thd U12 thd U23 thd U31 thd V1 thd V2 thd V3 Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% Table of current and voltage harmonics Decimal address 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 82 Hexa. address 900 901 902 903 904 905 906 907 908 909 90A 90B 90C 90D 90E 90F 910 911 912 913 914 915 916 917 918 919 91A 91B 91C Number of words 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I1 row 3 I2 row 3 I3 row 3 IN row 3 I1 row 5 I2 row 5 I3 row 5 IN row 5 I1 row 7 I2 row 7 I3 row 7 IN row 7 I1 row 9 I2 row 9 I3 row 9 IN row 9 I1 row 11 I2 row 11 I3 row 11 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Table of current and voltage harmonics (continued) Decimal address 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 Hexa. address 91D 91E 91F 920 921 922 923 924 925 926 927 928 929 92A 92B 92C 92D 92E 92F 930 931 932 933 934 935 936 937 938 939 93A 93B 93C 93D 93E 93F 940 941 942 943 944 945 946 947 948 949 94A 94B 94C 94D 94E 94F 950 951 952 953 RUDOLF - Ref. : CDR 27 028_gb Number of words 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Text Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Harmonic Unit IN row 11 I1 row 13 I2 row 13 I3 row 13 IN row 13 I1 row 15 I2 row 15 I3 row 15 IN row 15 U12 row 3 U23 row 3 U31 row 3 U12 row 5 U23 row 5 U31 row 5 U12 row 7 U23 row 7 U31 row 7 U12 row 9 U23 row 9 U31 row 9 U12 row 11 U23 row 11 U31 row 11 U12 row 13 U23 row 13 U31 row 13 U12 row 15 U23 row 15 U31 row 15 V1 row 3 V2 row 3 V3 row 3 V1 row 5 V2 row 5 V3 row 5 V1 row 7 V2 row 7 V3 row 7 V1 row 9 V2 row 9 V3 row 9 V1 row 11 V2 row 11 V3 row 11 V1 row 13 V2 row 13 V3 row 13 V1 row 15 V2 row 15 V3 row 15 I1 row 17 I2 row 17 I3 row 17 IN row 17 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 83 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Table of current and voltage harmonics Decimal Hexa. Number Text address address of words 2388 954 1 Harmonic I1 row 19 2389 955 1 Harmonic I2 row 19 2390 956 1 Harmonic I3 row 19 2391 957 1 Harmonic IN row 19 2392 958 1 Harmonic I1 row 21 2393 959 1 Harmonic I2 row 21 2394 95A 1 Harmonic I3 row 21 2395 95B 1 Harmonic IN row 21 2396 95C 1 Harmonic I1 row 23 2397 95D 1 Harmonic I2 row 23 2398 95E 1 Harmonic I3 row 23 2399 95F 1 Harmonic IN row 23 2400 960 1 Harmonic I1 row 25 2401 961 1 Harmonic I2 row 25 2402 962 1 Harmonic I3 row 25 2403 963 1 Harmonic IN row 25 2404 964 1 Harmonic U12 row 17 2405 965 1 Harmonic U23 row 17 2406 966 1 Harmonic U31 row 17 2407 967 1 Harmonic U12 row 19 2408 968 1 Harmonic U23 row 19 2409 969 1 Harmonic U31 row 19 2410 96A 1 Harmonic U12 row 21 2411 96B 1 Harmonic U23 row 21 2412 96C 1 Harmonic U31 row 21 2413 96D 1 Harmonic U12 row 23 2414 96E 1 Harmonic U23 row 23 2415 96F 1 Harmonic U31 row 23 2416 970 1 Harmonic U12 row 25 2417 971 1 Harmonic U23 row 25 2418 972 1 Harmonic U31 row 25 2419 973 1 Harmonic V1 row 17 2420 974 1 Harmonic V2 row 17 2421 975 1 Harmonic V3 row 17 2422 976 1 Harmonic V1 row 19 2423 977 1 Harmonic V2 row 19 2424 978 1 Harmonic V3 row 19 2425 979 1 Harmonic V1 row 21 2426 97A 1 Harmonic V2 row 21 2427 97B 1 Harmonic V3 row 21 2428 97C 1 Harmonic V1 row 23 2429 97D 1 Harmonic V2 row 23 2430 97E 1 Harmonic V3 row 23 2431 97F 1 Harmonic V1 row 25 2432 980 1 Harmonic V2 row 25 Size of this zone : 130 words (decimal) or 82 (hexadecimal) 84 Unit 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% 0.10% RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED (FUNCTION 3) Option recognition table Decimal address 257 258 Hexa. address 101 102 Number of words 1 1 Text Product code Slot option 1 0xFF : no option 0x00 : communication option 0x01 : metering option 0x03 : metering and harmonics option 0x20 : inputs/outputs option 0x30 : analog outputs option 0x40 : memory option 0x50 : Profibus option 0xF0 : presence of IN measure 259 103 1 Slot option 2 260 104 1 Slot option 3 261 105 1 Slot option 4 262 106 1 Version number 263 107 2 Serial number Size of this zone : 8 words (decimal) or 8 (hexadecimal) RUDOLF - Ref. : CDR 27 028_gb Unit – – – – – – – 85 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) 86 Decimal address 512 Hexa. address 200 Number of words 1 513 201 1 514 515 202 203 1 1 516 518 204 206 2 1 519 207 1 520 208 1 521 209 1 522 20A 1 Text Unit Network type: 0 : 1BL 1 : 2BL 2 : 3BL 3 : 3NBL 4 : 4BL 5 : 4NBL CT secondary : 1:1A 5:5A CT primary Voltage input on PT: 0 : No 1: Yes PT primary PT secondary: 60 : 60 V 100 : 100 V 110 : 110 V 115 : 115 V 120 : 120 V 173 : 173 V 190 : 190 V Synchronisation of I AVG/MAX: Time in seconds, possible values 2 : 2 seconds 10 : 10 seconds 300 : 5 minutes (5x60s) 480 : 8 minutes (8x60s) 600 : 10 minutes (10x60s) 900 : 15 minutes (15x60s) 1200 : 20 minutes (20x60s) 1800 : 30 minutes (30x60s) 3600 : 60 minutes (60x60s) Synchronisation of P/Q/S AVG/MAX: Time in seconds, possible values 10 : 10 seconds 300 : 5 minutes (5x60s) 480 : 8 minutes (8x60s) 600 : 10 minutes (10x60s) 900 : 15 minutes (15x60s) 1200 : 20 minutes (20x60s) 1800 : 30 minutes (30x60s) 3600 : 60 minutes (60x60s) OUT 1 allocation of the pulse output: 0 : kWh + 1 : kvarh + 2 : kVAh 3 : kWh 4 : kvarh OUT1 impulse value: 0 : 0.1 kWh/kvarh/kVAh 1 : 1 kWh/kvarh/kVAh 2 : 10 kWh/kvarh/kVAh – A A – V V s s – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address Hexa. address Number of words 523 20B 1 524 20C 1 525 20D 1 526 20E 1 527 20F 1 528 210 1 RUDOLF - Ref. : CDR 27 028_gb Text 3 : 100 kWh/kvarh/kVAh 4 : 1000 kWh/kvarh/kVAh 5 : 10000 kWh/kvarh/kVAh OUT 1 impulse duration: 1 : 100 ms 2 : 200 ms 3 : 300 ms 4 : 400 ms 5 : 500 ms 6 : 600 ms 7 : 700 ms 8 : 800 ms 9 : 900 ms OUT 2 allocation of the pulse output: 0 : kWh + 1 : kvarh + 2 : kVAh 3 : kWh 4 : kvarh OUT 2 impulse value: 0 : 0.1 kWh/kvarh/kVAh 1 : 1 kWh/kvarh/kVAh 2 : 10 kWh/kvarh/kVAh 3 : 100 kWh/kvarh/kVAh 4 : 1000 kWh/kvarh/kVAh 5 : 10000 kWh/kvarh/kVAh OUT 2 impulse duration : 1 : 100 ms 2 : 200 ms 3 : 300 ms 4 : 400 ms 5 : 500 ms 6 : 600 ms 7 : 700 ms 8 : 800 ms 9 : 900 ms Type of analog output OUT 1: 0 : 0/20 mA 1 : 4/20 mA 2 : 30 V Output allocation analog OUT 1: 0: I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7 : ΣP 8 : ΣQ 9 : ΣS 10 : ΣPFL 11 : V1 12 : V2 Unit – – – – – – 87 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address 88 Hexa. address Number of words 529 530 211 212 1 1 531 532 213 214 1 1 533 215 1 534 216 1 535 536 217 218 1 1 537 538 219 21A 1 1 539 21B 1 540 21C 1 Text Unit 13 : V3 14 : F 15 : ΣPFC Value at 0 or 4 mA from analog output OUT 1 Unit at 0 or 4 mA from analog output OUT 1: 0:/ 1:k 2:M Value at 20 mA from analog output OUT 1 Unit at 20 mA from analog output OUT 1: 0:/ 1:k 2:M Type of analog output OUT 2 : 0 : 0/20 mA 1 : 4/20 mA 2 : 30 V Output allocation analog OUT 2: 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7 : ΣP 8 : ΣQ 9 : ΣS 10 : ΣPFL 11 : V1 12 : V2 13 : V3 14 : F 15 : ΣPFC Value at 0 or 4 mA from analog output OUT 2 Unit at 0 or 4 mA from analog output OUT 2 : 0:/ 1:k 2:M Value at 20 mA from analog output OUT 2: Unit at 20 mA from analog output OUT 2: 0:/ 1:k 2:M Type of analog output OUT 3: 0 : 0/20 mA 1 : 4/20 mA 2 : 30 V Output allocation analog OUT 3: 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 – – – – – – – – – – – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address Hexa. address Number of words 541 542 21D 21E 1 1 543 544 21F 220 1 1 545 221 1 546 222 1 547 548 223 224 1 1 549 550 225 226 1 1 551 227 1 RUDOLF - Ref. : CDR 27 028_gb Text 7 : ΣP 8 : ΣQ 9 : ΣS 10 : ΣPFL 11 : V1 12 : V2 13 : V3 14 : F 15 : ΣPFC Value at 0 or 4 mA from analog output OUT 3 Unit at 0 or 4 mA from analog output OUT 3: 0:/ 1:k 2:M Value at 20 mA from analog output OUT 3 Unit at 20 mA from analog output OUT 3: 0:/ 1:k 2:M Type of analog output OUT 4: 0 : 0/20 mA 1 : 4/20 mA 2 : 30 V Output allocation analog OUT 4: 0 : I1 1 : I2 2 : I3 3 : In 4 : U12 5 : U23 6 : U31 7 : ΣP 8 : ΣQ 9 : ΣS 10 : ΣPFL 11 : V1 12 : V2 13 : V3 14 : F 15 : ΣPFC Value at 0 or 4 mA from analog output OUT 4 Unit at 0 or 4 mA from analog output OUT 4: 0:/ 1:k 2:M Value at 20 mA from analog output OUT 4 Unit at 20 mA from analog output OUT 4: 0:/ 1:k 2:M Allocation of OUT 1 relay: 0 : Cde 1:I 2:U 3 : ΣP+ 4 : ΣQ+ 5 : ΣS Unit – – – – – – – – – – – 89 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address 90 Hexa. address Number of words 552 553 228 229 1 1 554 555 22A 22B 1 1 556 557 558 22C 22D 22E 1 1 1 559 22F 1 560 561 230 231 1 1 562 563 232 233 1 1 Text 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Lower threshold OUT 1 Unit lower threshold OUT 1: 0:/ 1:k 2:M Threshold value OUT 1 Unit threshold value OUT : 0:/ 1:k 2:M Hysteresis 0 to 99 OUT 1 Specified time OUT 1 Relay status OUT 1: 0 : Open 1 : Closed Allocation of OUT 2 relay : 0 : Cde 1:I 2:U 3 : ΣP+ 4 : ΣQ+ 5 : ΣS 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Lower threshold OUT 2 Unit lower threshold OUT 2: 0:/ 1:k 2:M Threshold value OUT 2 Unit upper threshold OUT 2: 0: / 1:k 2:M Unit – – – – % s. – – – – – – RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address 564 565 566 567 568 569 570 571 Hexa. address 234 235 236 237 238 239 23A 23B Number of words 1 1 1 1 1 1 1 1 572 573 23C 23D 1 1 574 23E 1 575 23F 1 576 240 1 577 241 1 578 242 1 579 243 1 580 244 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Hysteresis 0 to 99 OUT 2 Specified time OUT 2 Relay status OUT 2 : 0 : Open 1 : Closed Relay status OUT 3 : 0 : Open 1 : Closed Relay status OUT 4 : 0 : Open 1 : Closed Relay status OUT 5 : 0 : Open 1 : Closed Relay status OUT 6 : 0 : Open 1 : Closed CT secondary neutral : 1: 1 A 5: 5 A CT primary neutral Synchronisation of U AVG/MAX : 10 : 10 seconds 300 : 5 minutes (5x60s) 480 : 8 minutes (8x60s) 600 : 10 minutes (10x60s) 900 : 15 minutes (15x60s) 1200 : 20 minutes (20x60s) 1800 : 30 minutes (30x60s) 3600 : 60 minutes (60x60s) Synchronisation of F AVG/MAX : 10 : 10 seconds 300 : 5 minutes (5x60s) 480 : 8 minutes (8x60s) 600 : 10 minutes (10x60s) 900 : 15 minutes (15x60s) 1200 : 20 minutes (20x60s) 1800 : 30 minutes (30x60s) 3600 : 60 minutes (60x60s) Mean power memory storage P+ : 0 : no 1 : yes Mean power memory storage P- : 0 : no 1 : yes Mean power memory storage Q+ : 0 : no 1 : yes Mean power memory storage Q- : 0 : no 1 : yes Mean power synchronisation signal : 0 : internal 1 : external Synchronisation period for P+, P-, Q+ et Q-: 300 : 5 minutes (5x60s) 480 : 8 minutes (8x60s) 600 : 10 minutes (10x60s) 900 : 15 minutes (15x60s) 1200 : 20 minutes (20x60s) 1800 : 30 minutes (30x60s) % s. – – – – – A A s. s. s. 91 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) 92 Decimal address 581 Hexa. address 245 Number of words 1 582 583 246 247 1 1 584 585 248 249 1 1 586 587 588 24A 24B 24C 1 1 1 589 24D 1 Text Allocation of OUT 3 relay: 0 : Cde 1:I 2:U 3 : ΣP+ 4 : ΣQ+ 5 : ΣS 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Lower threshold OUT 3 Unit lower threshold OUT 3 : 0:/ 1:k 2:M Upper threshold OUT 3 Unit upper threshold OUT 3 : 0:/ 1:k 2:M Hysteresis 0 to 99 OUT 3 Specified time OUT 3 Relay status OUT 3 : 0 : Open 1 : Closed Allocation of OUT 4 relay: 0 : Cde 1:I 2:U 3 : ΣP+ 4 : ΣQ+ 5 : ΣS 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Unit % s. RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address 590 591 Hexa. address 24E 24F Number of words 1 1 592 593 250 251 1 1 594 595 596 252 253 254 1 1 1 597 255 1 598 599 256 257 1 1 600 601 258 259 1 1 602 603 604 25A 25B 25C 1 1 1 605 25D 1 RUDOLF - Ref. : CDR 27 028_gb Text Lower threshold OUT 4 Unit lower threshold OUT 4 : 0:/ 1:k 2:M Upper threshold OUT 4 Unit upper threshold OUT 4 : 0:/ 1:k 2:M Hysteresis 0 to 99 OUT 4 Specified time OUT 4 Relay status OUT 4 : 0 : Open 1 : Closed Allocation of OUT 5 relay: 0 : Cde 1:I 2:U 3 : ΣP+ 4 : ΣQ+ 5 : ΣS 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Lower threshold OUT 5 Unit lower threshold OUT 5 : 0:/ 1:k 2:M Upper threshold OUT 5 Unit upper threshold OUT 5 : 0:/ 1:k 2:M Hysteresis 0 to 99 OUT 5 Specified time OUT 5 Relay status OUT 5 : 0 : Open 1 : Closed Allocation of OUT 6 relay: 0 : Cde 1:I 2:U Unit % s. % s. 93 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LIST OF PARAMETERS TO BE DISPLAYED OR PROGRAMMED (FUNCTION 3, 6 OR 16) Decimal address Hexa. address Number of words 606 607 25E 25F 1 1 608 609 260 261 1 1 610 611 612 262 263 264 1 1 1 613 614 265 266 1 1 615 267 1 616 268 1 Text Unit 3 : ΣP+ 4 : ΣQ+ 5 : ΣS 6:F 7 : ΣPFL 8 : thd 3I 9 : thd 3U 10 : IN 11 : HOUR 12 : V 13 : thd In 14 : thd 3V 15 : ΣP16 : ΣQ17 : ΣPFC 18 : Cd-t Lower threshold OUT 6 Unit lower threshold OUT 6 : 0:/ 1:k 2:M Upper threshold OUT 6 Unit upper threshold OUT 6 : 0:/ 1:k 2:M Hysteresis 0 to 99 OUT 6 Specified time OUT 6 Relay status OUT 6 : 0 : Open 1 : Closed Voltage dips detection threshold (SAG) Voltage dip detection threshold hysteresis (SAG) Voltage surge detection threshold hysteresis (SWELL) Voltage surge detection threshold hysteresis (SWELL) % s. % % % % Size of this zone: 105 words (decimals) or 69 (hexadecimals) Example: Configuration of a 4-wired unbalanced network (4 NBL) for R-DPA96 number 5. Slave Function High-order address Low-order address High-order word N° Low-order word N° CRC 16 05 06 02 00 00 05 49F5 R-DPA96 A/AN reply: Identical to message sent. 94 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION RESET TO ZERO: ENERGY METERS AND MAX. VALUES (FUNCTION 6) Decimal address 1024 Hexa. address 400 Number of words 1 1025 401 1 1026 402 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit RAZ: Max3I : 0 x 0001 MaxP+ : 0 x 0002 MaxP-: 0 x 0004 MaxQ+ : 0 x 0008 MaxQ- : 0 x 0010 MaxS : 0 x 0020 Hour meter : 0 x 0040 kWh+ : 0 x 0080 kvarh+ : 0 x 0100 kVAh : 0 x 0200 kWh- : 0 x 0400 kvarh- : 0 x 0800 All parameters : 0 x 1000 MaxU : 0 x 2000 MaxV : 0 x 4000 MaxF : 0 x 8000 R.A.Z. : E1 : 0 x 0001 E2 : 0 x 0002 E3 : 0 x 0004 E4 : 0 x 0008 E5 : 0 x 0010 E6 : 0 x 0020 Min/Max I : 0 x 0040 Min/Max In : 0 x 0080 Min/Max U : 0 x 0100 Min/Max F : 0 x 0200 Min/Max PF : 0 x 0400 Min/Max P : 0 x 0800 Min/Max Q : 0 x 1000 Min/Max thd I : 0 x 2000 Min/Max thd In : 0 x 4000 Min/Max thd U : 0 x 8000 RAZ: Min/Max thd V : 0 x 0001 Min/Max V : 0 x 0002 Min/Max S : 0 x 0004 10 alarms event log : 0 x 0008 10 voltage dips event log : 0 x 0010 10 surges event log : 0 x 0020 10 cut-offs event log : 0 x 0040 Averaged out frequencies : 0 x 0080 Averaged out voltage values : 0 x 0100 Averaged out power values : 0 x 0200 95 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION RESET TO ZERO: ENERGY METERS AND MAX. VALUES (FUNCTION 6) NB: To reset several parameters to zero, add the corresponding figure indicated in the “text” column. Example: reset Max P+ and kvarh + to zero: 2 + 100 = 102 (Hex) Example: To reset all values for R-DPA96 number 5 to zero, the following frame should be sent: Slave Function High-order address Low-order address High-order word N° Low-order word N° CRC 16 05 06 04 00 10 00 84BE R-DPA96 A/AN reply: identical to the message sent. SAVED COMMAND (RESET) The following command should be done to save programming parameters changes for R-DPA96 number 5. Slave Function High-order address Low-order address Values CRC 16 05 06 06 00 0000 88C6 NB : R-DPA96 A/AN will not reply to this command. PULSE METERS VALUES Input meters Decimal Hexa. Number Text address address of words 2560 A00 2 Input E1, option ES 1 2562 A02 2 Input E2, option ES 1 2564 A04 2 Input E3, option ES 2 2566 A06 2 inputE4, option ES 2 2568 A08 2 Input E5, option ES 3 2570 A0A 2 Input E6, option ES 3 Size of this zone: 12 words (decimals) or C (hexadecimals) 96 Unit RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION DATE AND HOUR SETTINGS (FUNCTION 3, 6 OR 16) Input meters Decimal Hexa. Number address address of words 3072 C00 1 3073 C01 1 3074 C02 1 3075 C03 1 3076 C04 1 3077 C05 1 Zone size: 6 words (decimal) or 6 (hexadecimal). Text Unit Day Month Year Hour Minute Second LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-1 Decimal address 3088 3089 Hexa. address C10 C11 Number of words 1 1 3090 3092 C12 C14 2 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Alarm output number (1 to 6) Lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold: 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 97 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-1 Decimal address 3093 3095 3096 3097 3098 3099 3100 3101 Hexa. address Number of words C15 C17 C18 C19 C1A C1B C1C C1D 2 1 1 1 1 1 1 1 Hexa. address C1E C1F Number of words 1 1 Text 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s Alarm n-2 Decimal address 3102 3103 98 Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-2 Decimal address Hexa. address Number of words 3104 3106 C20 C22 2 1 3107 3109 3110 3111 3112 3113 3114 3115 C23 C25 C26 C27 C28 C29 C2A C2B 2 1 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s 99 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-3 Decimal address 3116 3117 Hexa. address C2C C2D Number of words 1 1 3118 3120 C2E C30 2 1 100 Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-3 Decimal address 3121 3123 3124 3125 3126 3127 3128 3129 Hexa. address Number of words C31 C33 C34 C35 C36 C37 C38 C39 2 1 1 1 1 1 1 1 Hexa. address C3A C3B Number of words 1 1 Text 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s Alarm n-4 Decimal address 3130 3131 RUDOLF - Ref. : CDR 27 028_gb Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC 101 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-4 Decimal address 3132 3134 Hexa. address C3C C3E Number of words 2 1 3135 3137 3138 3139 3140 3141 3142 3143 C3F C41 C42 C43 C44 C45 C46 C47 2 1 1 1 1 1 1 1 Hexa. address C48 C49 Number of words 1 1 Text Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s Alarm n-5 Decimal address 3144 3145 102 Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-5 Decimal address 3146 3148 Hexa. address C4A C4C RUDOLF - Ref. : CDR 27 028_gb Number of words 2 1 Text Unit 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC 103 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-5 Decimal address 3149 3151 3152 3153 3154 3155 3156 3157 Hexa. address C4D C4F C50 C51 C52 C53 C54 C55 Number of words 2 1 1 1 1 1 1 1 Decimal address 3158 3159 Hexa. address C56 C57 Number of words 1 1 3160 3162 C58 C5A 2 1 Text Upper threshold value Duration Day Month Year Hour Minute Second Unit s s Alarm n-6 104 Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarme n-6 Decimal address 3163 3165 3166 3167 3168 3169 3170 3171 Hexa. address Number of words C5B C5D C5E C5F C60 C61 C62 C63 2 1 1 1 1 1 1 1 Hexa. address C64 C65 Number of words 1 1 Text 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s Alarm n-7 Decimal address 3172 3173 RUDOLF - Ref. : CDR 27 028_gb Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 105 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-7 Decimal address Hexa. address Number of words 3174 3176 C66 C68 2 1 3177 3179 3180 3181 3182 3183 3184 C69 C6B C6C C6D C6E C6F C70 2 1 1 1 1 1 1 106 Text 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Unit s RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-8 Decimal address 3186 3187 Hexa. address C72 C73 Number of words 1 1 3188 3190 C74 C76 2 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 107 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-8 Decimal address 3191 3193 3194 3195 3196 3197 3198 Alarm n-9 Decimal address 3200 3201 108 Hexa. address Number of words C77 C79 C7A C7B C7C C7D C7E 2 1 1 1 1 1 1 Hexa. address C80 C81 Number of words 1 1 Text 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Text Unit s Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-9 Decimal address 3202 3204 Hexa. address C82 C84 Number of words 2 1 3205 3207 3208 3209 3210 3211 3212 3213 C85 C87 C88 C89 C8A C8B C8C C8D 2 1 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Upper threshold value Duration Day Month Year Hour Minute Second Unit s 109 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-10 Decimal address 3214 3215 Hexa. address C8E C8F Number of words 1 1 3216 3218 C90 C92 2 1 110 Text Unit Output number (1 to 6) Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC Lower threshold value Lower threshold : 0 : no alarm 1 : I1 2 : I2 3 : I3 4 : In 5 : U12 6 : U23 7 : U31 8 : ΣP+ 9 : ΣQ+ 10 : ΣS 11 : F 12 : ΣPFL 15 : thd I1 16 : thd I2 17 : thd I3 18 : thd U12 19 : thd U23 20 : thd U31 21 : HOUR RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 ALARMS EVENT LOG (FUNCTION 3) Alarm n-10 Decimal address Hexa. address Number of words Text 22 : V1 23 : V2 24 : V3 25 : thd In 26 : thd V1 27 : thd V2 28 : thd V3 29 : ΣP30 : ΣQ31 : ΣPFC 3219 C93 2 Upper threshold value 3221 C95 1 Duration 3222 C96 1 Day 3223 C97 1 Month 3224 C98 1 Year 3225 C99 1 Hour 3226 C9A 1 Minute 3227 C9B 1 Second Zone size: 140 words (decimal) or 8C (hexadecimal). Unit s LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-1 Decimal address 3328 Hexa. address D00 Number of words 1 3329 3331 D01 D03 2 1 3332 3334 3336 3337 3338 3339 3340 3341 D04 D06 D08 D09 D0A D0B D0C D0D 2 2 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Unit ms 111 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-2 Decimal address 3342 Hexa. address D0E Number of words 1 3343 3345 D0F D11 2 1 3346 3348 3350 3351 3352 3353 3354 3355 D12 D14 D16 D17 D18 D19 D1A D1B 2 2 1 1 1 1 1 1 Hexa. address D1C Number of words 1 3357 3359 D1D D1F 2 1 3360 3362 3364 3365 3366 3367 3368 3369 D20 D22 D24 D25 D26 D27 D28 D29 2 2 1 1 1 1 1 1 Voltage dip n-3 Decimal address 3356 112 Text Unit Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text ms Unit Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second ms RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-4 Decimal address 3370 Hexa. address D2A Number of words 1 3371 3373 D2B D2D 2 1 3374 3376 3378 3379 3380 3381 3382 3383 D2E D30 D32 D33 D34 D35 D36 D37 2 2 1 1 1 1 1 1 Hexa. address D38 Number of words 1 3385 3387 D39 D3B 2 1 3388 3390 3392 3393 3394 3395 3396 3397 D3C D3E D40 D41 D42 D43 D44 D45 2 2 1 1 1 1 1 1 Voltage dip n-5 Decimal address 3384 RUDOLF - Ref. : CDR 27 028_gb Text Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text Query! : phase-to-phase residual value: 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value: 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Unit ms Unit ms 113 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-6 Decimal address 3398 Hexa. address D46 Number of words 1 3399 3401 D47 D49 2 1 3402 3404 3406 3407 3408 3409 3410 3411 D4A D4C D4E D4F D50 D51 D52 D53 2 2 1 1 1 1 1 1 Hexa. address D54 Number of words 1 3413 3415 D55 D57 2 1 3416 3418 3420 3421 3422 3423 3424 3425 D58 D5A D5C D5D D5E D5F D60 D61 2 2 1 1 1 1 1 1 Voltage dip n-7 Decimal address 3412 114 Text Unit Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text ms Unit Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second ms RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-8 Decimal address 3426 Hexa. address D62 Number of words 1 3427 3429 D63 D65 2 1 3430 3432 3434 3435 3436 3437 3438 3439 D66 D68 D6A D6B D6C D6D D6E D6F 2 2 1 1 1 1 1 1 Hexa. address D70 Number of words 1 3441 3443 D71 D73 2 1 3444 3446 3448 3449 3450 3451 3452 3453 D74 D76 D78 D79 D7A D7B D7C D7D 2 2 1 1 1 1 1 1 Voltage dip n-9 Decimal address 3440 RUDOLF - Ref. : CDR 27 028_gb Text Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Unit ms Unit ms 115 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE DIPS EVENT LOG / SAG (FUNCTION 3) Voltage dip n-10 Decimal address 3454 Hexa. address D7E Number of words 1 3455 3457 D7F D81 2 1 3458 3460 3462 3463 3464 3465 3466 3467 D82 D84 D86 D87 D88 D89 D8A D8B 2 2 1 1 1 1 1 1 Text Unit Query! : phase-to-phase residual value : 0 : no 5: U12 6: U23 7: U31 Value Query! : phase-to-neutral residual value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second ms Zone size: 140 words (decimal) or 8C (hexadecimal). LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-1 Decimal address 3584 Hexa. address E00 Number of words 1 3585 3587 E01 E03 2 1 3588 3590 3592 3593 3594 3595 3596 3597 E04 E06 E08 E09 E0A E0B E0C E0D 2 2 1 1 1 1 1 1 116 Text Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration ms Day Month Year Hour Minute Second RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-2 Decimal address 3598 Hexa. address E0E Number of words 1 3599 3601 E0F E11 2 1 3602 3604 3606 3607 3608 3609 3610 3611 E12 E14 E16 E17 E18 E19 E1A E1B 2 2 1 1 1 1 1 1 Voltage surge n-3 Decimal Hexa. address address 3612 E1C Number of words 1 3613 3615 E1D E1F 2 1 3616 3618 3620 3621 3622 3623 3624 3625 E20 E22 E24 E25 E26 E27 E28 E29 2 2 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Unit ms Unit ms 117 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-4 Decimal address 3626 Hexa. address E2A Number of words 1 3627 3629 E2B E2D 2 1 3630 3632 3634 3635 3636 3637 3638 3639 E2E E30 E32 E33 E34 E35 E36 E37 2 2 1 1 1 1 1 1 Voltage surge n-5 Decimal Hexa. address address 3640 E38 Number of words 1 3641 3643 E39 E3B 2 1 3644 3646 3648 3649 3650 3651 3652 3653 E3C E3E E40 E41 E42 E43 E44 E45 2 2 1 1 1 1 1 1 118 Text Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text ms Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration ms Day Month Year Hour Minute Second RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-6 Decimal address 3654 Hexa. address E46 Number of words 1 3655 3657 E47 E49 2 1 3658 3660 3662 3663 3664 3665 3666 3667 E4A E4C E4E E4F E50 E51 E52 E53 2 2 1 1 1 1 1 1 Voltage surge n-7 Decimal Hexa. address address 3668 E54 Number of words 1 3669 3671 E55 E57 2 1 3672 3674 3676 3677 3678 3679 3680 3681 E58 E5A E5C E5D E5E E5F E60 E61 2 2 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Unit ms Unit ms 119 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-8 Decimal address 3682 Hexa. address E62 Number of words 1 3683 3685 E63 E65 2 1 3686 3688 3690 3691 3692 3693 3694 3695 E66 E68 E6A E6B E6C E6D E6E E6F 2 2 1 1 1 1 1 1 Voltage surge n-9 Decimal Hexa. address address 3696 E70 Number of words 1 3697 3699 E71 E73 2 1 3700 3702 3704 3705 3706 3707 3708 3709 E74 E76 E78 E79 E7A E7B E7C E7D 2 2 1 1 1 1 1 1 120 Text Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second Text ms Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration Day Month Year Hour Minute Second ms RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE SURGE EVENT LOG / SWELL (FUNCTION 3) Voltage surge n-10 Decimal address 3710 Hexa. address E7E Number of words 1 3711 3713 E7F E81 2 1 3714 3716 3718 3719 3720 3721 3722 3723 E82 E84 E86 E87 E88 E89 E8A E8B 2 2 1 1 1 1 1 1 Text Unit Query! : maximum phase-to-phase value : 0 : no 5: U12 6: U23 7: U31 Value Query! : maximum phase-to-neutral value : 0 : no 22 : V1 23 : V2 24 : V3 Value Duration ms Day Month Year Hour Minute Second Zone size: 140 words (decimal) or 8C (hexadecimal). MINIMUM AND MAXIMUM INSTANTANEOUS VALUES (FUNCTION 3) Decimal address 3840 3842 3843 3844 3845 3846 3847 3848 3850 3851 3852 3853 3854 3855 3856 3858 3859 3860 3861 3862 3863 3864 3866 3867 3868 3869 3870 3871 3872 Hexa. address F00 F02 F03 F04 F05 F06 F07 F08 F0A F0B F0C F0D F0E F0F F10 F12 F13 F14 F15 F16 F17 F18 F1A F1B F1C F1D F1E F1F F20 RUDOLF - Ref. : CDR 27 028_gb Number of words 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 Text Unit 3I minimum Day Month Year Hour Minute Second 3I maximum Day Month Year Hour Minute Second IN minimum Day Month Year Hour Minute Second IN maximum Day Month Year Hour Minute Second 3U minimum mA mA mA mA mV 121 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION MINIMUM AND MAXIMUM INSTANTANEOUS VALUES (FUNCTION 3) Decimal address 3874 3875 3876 3877 3878 3879 3880 3882 3883 3884 3885 3886 3887 3888 3890 3891 3892 3893 3894 3895 3896 3898 3899 3900 3901 3902 3903 3904 3906 3907 3908 3909 3910 3911 3912 3914 3915 3916 3917 3918 3919 3920 3922 3923 3924 3925 3926 3927 3928 3930 3931 3932 3933 3934 3935 3936 122 Hexa. address F22 F23 F24 F25 F26 F27 F28 F2A F2B F2C F2D F2E F2F F30 F32 F33 F34 F35 F36 F37 F38 F3A F3B F3C F3D F3E F3F F40 F42 F43 F44 F45 F46 F47 F48 F4A F4B F4C F4D F4E F4F F50 F52 F53 F54 F55 F56 F57 F58 F5A F5B F5C F5D F5E F5F F60 Number of words 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 Text Day Month Year Hour Minute Second 3U maximum Day Month Year Hour Minute Second 3V minimum Day Month Year Hour Minute Second 3V maximum Day Month Year Hour Minute Second F minimum Day Month Year Hour Minute Second F maximum Day Month Year Hour Minute Second ΣPF minimum Day Month Year Hour Minute Second ΣPF maximum Day Month Year Hour Minute Second ΣP + minimum Unit 0.01 V 0.01 V 0.01 V Hz / 100 Hz / 100 1 / 1000 1 / 1000 kW / 1000 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION MINIMUM AND MAXIMUM INSTANTANEOUS VALUES (FUNCTION 3) Decimal address 3938 3939 3940 3941 3942 3943 3944 3946 3947 3948 3949 3950 3951 3952 3954 3955 3956 3957 3958 3959 3960 3962 3963 3964 3965 3966 3967 3968 3970 3971 3972 3973 3974 3975 3976 3978 3979 3980 3981 3982 3983 3984 3986 3987 3988 3989 3990 3991 3992 3994 3995 3996 3997 3998 3999 4000 Hexa. address F62 F63 F64 F65 F66 F67 F68 F6A F6B F6C F6D F6E F6F F70 F72 F73 F74 F75 F76 F77 F78 F7A F7B F7C F7D F7E F7F F80 F82 F83 F84 F85 F86 F87 F88 F8A F8B F8C F8D F8E F8F F90 F92 F93 F94 F95 F96 F97 F98 F9A F9B F9C F9D F9E F9F FA0 RUDOLF - Ref. : CDR 27 028_gb Number of words 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 Text Day Month Year Hour Minute Second ΣP + maximum Day Month Year Hour Minute Second ΣP - minimum Day Month Year Hour Minute Second ΣP - maximum Day Month Year Hour Minute Second ΣQ + minimum Day Month Year Hour Minute Second ΣQ + maximum Day Month Year Hour Minute Second ΣQ - minimum Day Month Year Hour Minute Second ΣQ - maximum Day Month Year Hour Minute Second ΣS minimum Unit kW / 100 kW / 100 kvar / 100 kvar / 100 kvar / 100 kvar / 100 kvar / 100 kvar / 100 123 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION MINIMUM AND MAXIMUM INSTANTANEOUS VALUES (FUNCTION 3) Decimal address 4002 4003 4004 4005 4006 4007 4008 4010 4011 4012 4013 4014 4015 4016 4018 4019 4020 4021 4022 4023 4024 4026 4027 4028 4029 4030 4031 4032 4034 4035 4036 4037 4038 4039 4040 4042 4043 4044 4045 4046 4047 4048 4050 4051 4052 4053 4054 4055 4056 4058 4059 4060 4061 4062 4063 124 Hexa. address FA2 FA3 FA4 FA5 FA6 FA7 FA8 FAA FAB FAC FAD FAE FAF FB0 FB2 FB3 FB4 FB5 FB6 FB7 FB8 FBA FBB FBC FBD FBE FBF FC0 FC2 FC3 FC4 FC5 FC6 FC7 FC8 FCA FCB FCC FCD FCE FCF FD0 FD2 FD3 FD4 FD5 FD6 FD7 FD8 FDA FDB FDC FDD FDE FDF Number of words 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 Text Day Month Year Hour Minute Second ΣS maximum Day Month Year Hour Minute Second THD 3I minimum Day Month Year Hour Minute Second THD 3I maximum Day Month Year Hour Minute Second THD IN minimum Day Month Year Hour Minute Second THD IN maximum Day Month Year Hour Minute Second THD 3U minimum Day Month Year Hour Minute Second THD 3U maximum Day Month Year Hour Minute Second Unit kvar / 100 0.10 % 0.10 % 0.10 % 0.10 % 0.10 % 0.10 % RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION MINIMUM AND MAXIMUM INSTANTANEOUS VALUES (FUNCTION 3) Decimal address 4064 4066 4067 4068 4069 4070 4071 4072 4074 4075 4076 4077 4078 Hexa. address FE0 FE2 FE3 FE4 FE5 FE6 FE7 FE8 FEA FEB FEC FED FEE Number of words 2 1 1 1 1 1 1 2 1 1 1 1 1 Text Unit THD 3V minimum Day Month Year Hour Minute Second THD 3V maximum Day Month Year Hour Minute 0.10 % 0.10 % Zone size: 240 words (decimal) or FO (hexadecimal). LAST 10 VOLTAGE CUT-OFFS EVENT LOG / SAG (FUNCTION 3) Outage n-1 Decimal address 4096 4097 4098 4099 4100 4101 Hexa. address 1000 1001 1002 1003 1004 1005 Number of words 1 1 1 1 1 1 Outage n-2 Decimal address 4102 4103 4104 4105 4106 4107 Hexa. address 1006 1007 1008 1009 100A 100B Number of words 1 1 1 1 1 1 Outage n-3 Decimal address 4108 4109 4110 4111 4112 4113 Hexa. address 100C 100D 100E 100F 1010 1011 Number of words 1 1 1 1 1 1 Outage n-5 Decimal address 4114 4115 4116 4117 4118 4119 Hexa. address 1012 1013 1014 1015 1016 1017 Number of words 1 1 1 1 1 1 RUDOLF - Ref. : CDR 27 028_gb Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second 125 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) COMMUNICATION LAST 10 VOLTAGE CUT-OFFS EVENT LOG / SAG (FUNCTION 3) Outage n-5 Decimal address 4120 4121 4122 4123 4124 4125 Outage n-6 Decimal address 4126 4127 4128 4129 4130 4131 Hexa. address 1018 1019 101A 101B 101C 101D Number of words 1 1 1 1 1 1 Hexa. address 101E 101F 1020 1021 1022 1023 Number of words 1 1 1 1 1 1 Outage n-7 Decimal address 4132 4133 4134 4135 4136 4137 Hexa. address 1024 1025 1026 1027 1028 1029 Number of words 1 1 1 1 1 1 Outage n-8 Decimal address 4138 4139 4140 4141 4142 4143 Hexa. address 102A 102B 102C 102D 102E 102F Number of words 1 1 1 1 1 1 Outage n-9 Decimal address 4144 4145 4146 4147 4148 4149 Hexa. address 1030 1031 1032 1033 1034 1035 Number of words 1 1 1 1 1 1 Outage n-10 Decimal address 4150 4151 4152 4153 4154 4155 Hexa. address 1036 1037 1038 1039 103A 103B Number of words 1 1 1 1 1 1 Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Text Unit Day Month Year Hour Minute Second Zone size: 60 words (decimal) or 3C (hexadecimal). 126 RUDOLF - Ref. : CDR 27 028_gb R-DPA96 A/AN - R-MODULE 3 (RS485 - JBUS/MODBUS®) COMMUNICATION MEAN POWER EVENT LOG (FUNCTION 3) Decimal address 12288 12289 12290 12293 Hexa. address 3000 3001 3002 3004 Number of words 1 1 3 4500 16793 4198 4500 21293 532C 4500 25793 64C0 4500 30293 7655 Zone end Text Unit Mean active power pointer P+/PMean reactive power pointer Q+/QDate/Hour pointers updating Zone P.1 saving mean active power values P+ / PZone P.2 saving mean active power values P+ / PZone Q.1 saving mean reactive power values Q+ / QZone Q.2 saving mean reactive power values Q+ / Q- Zone size: 18005 words (decimal) or 4655 (hexadecimal). MEAN VOLTAGE EVENT LOG (FUNCTION 3) Decimal address 32768 32769 32772 33647 Hexa. address 8000 8001 8003 836E Number of words 1 2 875 Zone end Text Unit Voltage pointer Date/Hour pointer updating 3U, 3V voltage values V/100 Zone size: 879 words (decimal) or 36F (hexadecimal). MEAN FREQUENCY EVENT LOG (FUNCTION 3) Decimal address 36864 36865 36868 45568 Hexa. address 9000 9001 9003 B1FF Number of words 1 2 8700 Zone end Text Unit Frequency pointer Date/Hour pointer updating Frequency values Hz Zone size: 8704 words (decimal) or 220 (hexadecimal). RUDOLF - Ref. : CDR 27 028_gb 127 R-DPA96 A/AN - R-Module 3 ( RS485 - JBUS/MODBUS®) TECHNICAL CHARACTERISTICS COMMUNICATION RS485 Protocole Speed Galvanic insulation 2 or 3 wires half duplex JBUS/MODBUS® protocol / RTU mode 2400 to 38400 Bauds 4 kV CERTIFICATION UL 61010-1 N° file : E25 7746 GLOSSARY OF ABBREVIATIONS COM ADR BDS PAR NO Even Odd STOP 1 2 128 Communication Slave address Speed of communication in bauds Communication frame parity Without parity Even parity Odd parity Frame-stop beep 1 stop bit 2 stop bits RUDOLF - Ref. : CDR 27 028_gb RUDOLF - Ref. : 876 341 A 129 130 RUDOLF - Ref. : 876 341 A R-DPA96 A/AN - R-Module 4 2 Outputs 0/4 - 20 mA PRELIMINARY OPERATIONS When the package containing the optional module is received, the following points must be checked: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product, • the operating instructions. PRESENTATION This optional module must be connected to the RDPA96 A/AN (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). It provides 2 entirely configurable 0/4-20 mA analog outputs (threshold at 0 or 4 mA and threshold at 20 mA) on I1, I2, I3, In, U12, U23, U31,V1, V2, V3, ΣP, ΣQ, ΣS, ΣPFL/C and F The power supply output can also be used using the 30 V function. Up to a maximum of 2 modules, that is 4 analog outputs installed on one R-DPA96 A/AN. 131 R-DPA96 A/AN - R-Module 4 (0/4 - 20 mA) INSTALLATION CONNECTION This R-DPA96 A/AN must be switched off. 1 Fix the module DPA96 343 A DPA96 342 A 2 3 4 When using the four outputs, the two modules must be installed in the two left-hand positions as shown. OUT2 7 86 5 - + + OUT2 OUT1 7 86 5 - + + OUT4 OUT3 7 86 5 - + + DPA96 435 A OUT1 5 Follow indications when connecting the terminal. Switch on voltage supply. 132 RUDOLF - Ref. : 876 586 A R-DPA96 A/AN - R-Module 4 (0/4 - 20 mA) PROGRAMMING Previous menu p.134 p.135 p.136 p.137 p.138 p.138 p.138 Following menu RUDOLF - Ref. : 876 586 A 133 R-DPA96 A/AN - R-Module 4 (0/4 - 20 mA) PROGRAMMING N°1 ANALOG OUTPUT TYPE - Example : TYPE = 0 / 20 mA x1 x 1 : 0/20 mA x2 : 30 VDC x3 : 4/20 mA x1 confirm 134 RUDOLF - Ref. : 876 586 A R-DPA96 A/AN - R-MODULE 4 (0/4 - 20 mA) PROGRAMMING N° 1 ANALOG OUTPUT ALLOCATION - Example : PAR = Ι2 x1 x 1 (Ι2) x 2 (Ι3) x 3 (Ιn) x 4 (U12) x 5 (U23) x 6 (U31) x 7 (V1) x 8 (V2) x 9 (V3) x 10 (ΣP) x 11 (ΣQ) x 12 (ΣS) x 13 (ΣPFL) x 14 (ΣPFC) x 15 (F) x 16 (ISYS) x 17 (USYS) x 18 (VSYS) x 19 (I1) x1 confirm RUDOLF - Ref. : 876 586 A 135 R-DPA96 A/AN - R-Module 4 (0/4 - 20 mA) PROGRAMMING PROGRAMMING OF THE N°1 ANALOG OUTPUT AT 0 TO 4 MA Example: LV = 1000 kA NB : • For the power factor PF = 0 = 0 in programming ; PF = 0,5 = 500 in programming ; PF = 1 = 1 000 in programming. • For the frequency F = 40 Hz = 4000 in programming, F = 50 Hz = 5000 in programming. • For ∑P, ∑Q and ∑S the lower threshold (LV) corresponds to the negative value (example : -1000 kW). x1 x1 x4 x 1 (k) x 2 (/) x1 confirm 136 RUDOLF - Ref. : 876 586 A R-DPA96 A/AN - R-MODULE 4 (0/4 - 20 mA) PROGRAMMING PROGRAMMING OF THE N°1 ANALOG OUTPUT AT 20 MA Example: HV = 2000 kA NB : • For the power factor PF = 0 = 0 in programming ; PF = 0.5 = 500 in programming ; PF = 1 = 1 000 in programming. • For the frequency F = 40 Hz = 4000 in programming, F = 50 Hz = 5000 in programming. • For ΣP, ΣQ and ΣS the lower threshold (LV) corresponds to the negative value (example : -1000 kW). x1 x2 x4 x 1 (k) x 2 (/) x1 confirm RUDOLF - Ref. : 876 586 A 137 R-DPA96 A/AN - R-Module 4 (0/4 - 20 mA) PROGRAMMING PROGRAMMING OF N° 2, 3 AND 4 ANALOG OUTPUT Proceed as for number 1 analog output. Press t to return to network programming (Net) or to pass to number 2 analog output programming or press for 3 seconds on PROG to quit programming. TECHNICAL CHARACTERISTICS Analog outputs Load resistance Response time Galvanic insulation Accuracy (full scale) Certification 0 to 600 Ohms 1 sec 2.5 kV 0.5 % UL 61010-1 N° file : E25 7746 GLOSSARY OF ABBREVIATIONS Out 1 20 mA … Out 4 20 mA TYPE 0/20 4/20 30 VDC I1, I2, I3 In U12, U23, U31 V1, V2, V3 ΣP ΣQ ΣS F ΣPFL ΣPFC Out 1 20 mA LV …Out 4 20 mA LV Out 1 20 mA HV …Out 4 20 mA HV / K M I SYS, U SYS, V SYS 138 Analogue outputs nos. 1 to 4 Allocation of signal type 0-20 mA, 4-20 mA Relay status control via RS 485 Signal 4-20 mA 30 VDC feed to supply the optocoupler inputs of the 2IN/2OUT module Current I1, I2, I3 Neutral current Phase-to-phase voltage U12, U23, U31 Phase-to-neutral voltage V1, V2, V3 Total active power Total reactive power Total effective power Frequency Power factor (lagging) Power factor (leading) Value at 0 or 4 mA Value at 4-20 mA Value displayed (e.g. : A = Amps) Kilo (e.g. : kA = kilo amps) Mega (e.g. : MA = mega amps) Current, phase to phase voltage, phase to neutral voltage system RUDOLF - Ref. : 876 586 A RUDOLF - Ref. : 876 586 A 139 140 RUDOLF - Ref. : 876 586 A R-DPA96 A/AN - R-Module 5 2 Inputs / 2 Outputs PRELIMINARY OPERATIONS Check the following points as soon as you receive the optional module package: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product, • the operating instructions. PRESENTATION This optional module must be connected to the RDPA96A/AN - Main Module (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). For the monitoring function, programming of an upper and lower threshold, of the hysteresis, of the time delay and of the run mode for 3I, 3U, 3V, In, ΣP, ΣQ, ΣS, F and ΣFPL/C, thd 3I, thd 3U, thd 3V, thd In, HOUr. Possibility of installing up to 3 modules, that is 6 inputs / 6 outputs. This module provides instant storage of min/max values for the 3U, 3F, In, ±ΣP, ±ΣQ, ΣPF, F, thd 3U, thd 3I and thd In via the RS 485. Comment : For the DPA96 and DPA96 A (version 1.03), only 2 of the 6 outputs can be set for monitoring. For the 6 inputs, only 2 are visible on the display. 141 R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) INSTALLATION CONNECTION This R-DPA96 A/AN must be switched off. 1 Fix the module DPA96A 343 A DPA96A 342 A 2 3 OUT1 1 OUT2 2 3 4 11 15 16 - + + DPA96A 433 A 1 09 11 1 2 IN1 N IN2 142 RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - MODULE 5 (2 Intput / 2 Output) INSTALLATION CONNECTION 4 Follow indications when connecting the terminal. Switch on voltage supply. 9 1 2 3 10 OUT 1 OUT 3 OUT 5 13 1 2 3 5 14 IN 1 IN 3 IN 5 11 12 OUT 2 OUT 4 OUT 6 15 16 IN 2 IN 4 IN 6 When installing 2 or 3 modules (maximum), the modules should be installed as indicated above. RUDOLF Ref. : 876 587 A 143 R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) PROGRAMMING Previous menu p 145 p 146 p 147 p 148 p 148 p 149 p 149 p 149 Following menu 144 RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - MODULE 5 (2 Intput / 2 Output) PROGRAMMING N°1 OUTPUT RELAY TYPE - Example : TYPE = Ι x1 x 1 (Ι) x 2 (Ιn) x 3 (U) x 4 (V) x 5 (ΣP+) x 6 (ΣP-) x 7 (ΣQ+) x 8 (ΣQ-) x 9 (ΣS) x 10 (ΣPFL) x 11 (ΣPFC) x 12 (F) x 13 (HOUr) x 14 (THD Ι) x 15 (THD ΙN) x 16 (THD U) x 17 (THD V) x 18 (CDE) x 19 (CD-t) x1 RUDOLF Ref. : 876 587 A 145 R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) PROGRAMMING N° 1 OUTPUT RELAY UPPER THRESHOLD - Example : Ht = 100 kA x2 x1 x3 x1 x1 confirm 146 RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - MODULE 5 (2 Intput / 2 Output) PROGRAMMING N° 1 OUTPUT RELAY LOWER THRESHOLD - Example : Lt = 10 kA x3 x1 x2 x1 x1 confirm RUDOLF Ref. : 876 587 A 147 R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) PROGRAMMING N° 1 OUTPUT RELAY HYSTERESIS - Example : HYST = 20 % x1 x2 x1 confirm N° 1 OUTPUT RELAY TIME DELAY - Example : TEMPO = 30 s x2 x3 x1 confirm 148 RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - MODULE 5 (2 Intput / 2 Output) PROGRAMMING N° 1 OUTPUT RELAY RUN MODE - Example : RELAY = NC x1 x2 x1 confirm PROGRAMMING RELAY OUTPUTS N°S 2 - 3 - 4 - 5 - 6- Proceed as for number 1 relay output. RUDOLF Ref. : 876 587 A 149 R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) OPERATION DPA96A DPA96A DPA96A 150 DPA96A DPA96A RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - R-Module 5 (2 Inputs / 2 Outputs) TECHNICAL CHARACTERISTICS Relay outputs Relay max. 230 V AC – 5 A – 1150 VA N° of operations ≤ 105 Galvanic insulation 2.5 kV Response time 1s Certification UL 61010-1 N° file : E25 7746 Optocoupler inputs Max. direct voltage Min. direct voltage Max. inverse voltage Galvanic insulation Min. pulse duration Max number of operations 30 V DC 10 V DC 30 V DC 3 kV 10 ms 108 GLOSSARY OF ABBREVIATIONS Out 1 A-Cd… Out 6 A-Cd In1 … In 2 TYPE CDE I In U V ΣP+ ΣPΣQ+ ΣQΣS F ΣPFL ΣPFC THD I THD In THD U THD V HOUr CD-t Out 1 Ht…Out 6 Ht Out 1 Lt … Out 6 Lt / K M Out 1 HYST … Out 6 HYST Out 1 TEMPO … Out 6 TEMPO Out 1 RELAY … Out 6 RELAY NC NO RUDOLF Ref. : 876 587 A Relay outputs 1 to 6 Optocoupler inputs 1 to 6 Output relays allocation Relay status control via RS 485 Current I1, I2, I3 Neutral current Phase-to-phase voltage U12, U23, U31 Phase-to-neutral voltage V1, V2, V3 Total positive active power Total negative active power Total positive reactive power Total negative reactive power Total effective power Frequency Power factor (lagging) Power factor (leading) Current harmonic distortion (phases) Current harmonic distortion (neutral) Phase-to-phase harmonic distortion Phase-to-neutral harmonic distortion Hour meter Relay status control via RS 485 with return to unenergised state Alarm upper threshold Alarm lower threshold Value displayed (e.g. : A = Amps) Kilo (e.g. : kA = kilo amps) Mega (e.g. : MA = mega amps) Hysteresis from 0 to 99% Relay switching time delay from 0 to 999 s. Unenergised output relay Relay normally off Relay normally on 151 152 RUDOLF - Ref. : 876 587 A R-DPA96 A/AN - R-Module 7 MEMORY RY O M ME WARNING Caution: There is a risk of explosion if the battery is replaced with a battery of the incorrect type. Dispose of used batteries in line with the instructions. PRELIMINARY OPERATIONS Check the following points as soon as you receive the optional module package: • the packing is in good condition, • the product has not been damaged during transit, • the product reference number conforms to your order, • the package contains the product, • the operating instructions. 153 R-DPA96 A/AN - R-Module 7 (Memory) PRESENTATION This optional module must be connected to the R-DPA96A/AN (ref. 4825 0A40, 4825 0A41, 4825 1A40, 4825 1A41). It offers the following functions via the RS485 JBUS/MODBUS communication interfaces : • 31-day storing of P+, P-, Q+, Q- with a 10-minute internal / external synchronisation signal. This signal can be set to 5, 8, 10, 15, 20, 30 and 60 minutes. Storing of the above values can be done over a 62-day period if saving a single active or reactive power value. • Storing the last 10 date-stamped alarms (date/hour, duration, minimum and maximum values). 154 • Storing the last min./max. instantaneous values for 3U, 3V, 3I, In, F, ΣP+/-, ΣQ+/-, ΣS, THD3U, THD3V, THD 3I, THD In. • Stamp-dated storing of the 10 last : - voltage dips from 5% to 95% of Un (as per IEC 61000-430 and EN 50160) with 10 ms tripping time. - Transient overvoltage from 105% to 150% of Un (voltage surges) from a 10 ms build-up time. - Voltage cut-offs from a value less than 5% of Un. • Storing of mean values according to synchronisation signal for 3U, 3V (1 day in 10 minutes) and F (60 days in 10 minutes). RUDOLF - Ref. : 876 588 A R-DPA96 A/AN - R-Module 7 (Memory) INSTALLATION CONNECTION This R-DPA96 A/AN must be switched off. 1 Fix the module on the slot 2 or 3 DPA96 674 A DPA96 342 A 2 3 18 17+ - DPA96 675 A IN synchro RUDOLF - Ref. : 876 588 A 155 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING Previous menu P. 158 P. 158 P. 158 P. 158 P. 159 P. 160 P. 161 156 RUDOLF - Ref. : 876 588 A R-DPA96 A/AN - R-MODULE 7 (Memory) PROGRAMMING P. 162 P. 163 P. 164 P. 165 P. 166 P. 167 Following menu RUDOLF - Ref. : 876 588 A 157 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING SAVING ACTIVE POWER CONSUMPTION DEMAND - Example : MEMO P+ = YES NB : Proceed in the same way for P-, Q+ and Q-. - 31-day storing of P+, P-, Q+, Q- with a 10-minute internal / external synchronisation signal. Storing of the above values can be done over a 62-day period if saving a single active or reactive power value. x1 x 1 (YES) x 2 (NO) x1 confirm 158 RUDOLF - Ref. : 876 588 A R-DPA96 - R-MODULE 7 (Memory) PROGRAMMING INTERNAL / EXTERNAL SYNCHRONISATION MODE - Example : MEMO TOP = EXT x1 x 1 (EXT) x 2 (INT) x1 confirm RUDOLF - Ref. : 876 588 A 159 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING SYNCHRONISATION SIGNAL - Example : MEMO TIME = 10’ x1 x 1 (20 min) x 2 (30 min) x 3 (5 min) x 4 (8 min) x 5 (10 min) x 6 (15 min) x1 confirm DEFINING VOLTAGE DIPS, SURGES AND CUT-OFFS Voltage dips and overvoltage (voltage surges) are stored as per IEC161000-4-30 and EN50160 with a Class B measurement method > Voltage dips The voltage dips threshold can be set to between 5% and 95 % of the reference voltage value. Likewise, the dip is considered as terminated when it passes over the dip threshold, plus the voltage hysteresis. > Overvoltage The overvoltage is threshold can be set to 105%-150% of the reference voltage value. The overvoltage is terminated when it is under the dip threshold, less the voltage hysteresis > Voltage cut-offs It is considered that there is a voltage cut-off if one of the phases is lower than minimum of measurement of Dpa96 (see Dpa96 technical characteristics). 160 RUDOLF - Ref. : 876 588 A R-DPA96 - R-MODULE 7 (Memory) PROGRAMMING VOLTAGE DIP THRESHOLD (SAG)- Example : dAtA SAG = 15% x1 x1 x1 confirm RUDOLF - Ref. : 876 588 A 161 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING VOLTAGE DIP HYSTERESIS - Example : dAtA HySt SAG = 5% x1 x3 x1 confirm 162 RUDOLF - Ref. : 876 588 A R-DPA96 - R-MODULE 7 (Memory) PROGRAMMING OVERVOLTAGE THRESHOLD (SWELL) - Example : dAtA SWELL = 115 % x3 x5 x1 confirm RUDOLF - Ref. : 876 588 A 163 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING OVERVOLTAGE HYSTERESIS - Example : dAtA HySt SWELL = 5% x1 x3 x1 confirm 164 164 RUDOLF - Ref. : 876 588 A R-DPA96 - R-MODULE 7 (Memory) PROGRAMMING ACTIVATING DATE / HOUR FUNCTION - Example : dAtE tIME = YES x1 x 1 (YES) x 2 (NO) x1 confirm RUDOLF - Ref. : 876 588 A 165 R-DPA96 A/AN - R-Module 7 (Memory) PROGRAMMING DATE SETTINGS - Example : dAtE = 19-07-05 x1 x1 x1 x9 x2 x7 x2 x5 x1 confirm 166 RUDOLF - Ref. : 876 588 A R-DPA96 - R-MODULE 7 (Memory) PROGRAMMING HOUR SETTINGS - Example : tIME 14h02’30” x1 x1 x1 x4 x2 x2 x1 x3 x1 confirm RUDOLF - Ref. : 876 588 A 167 R-DPA96 A/AN - R-Module 7 (Memory) OPERATION DPA96A DPA96A 168 RUDOLF - Ref. : 876 588 A R-DPA96 A/AN - R-Module 7 (Memory) TECHNICAL CHARACTERISTICS Optocoupler input Max. direct voltage Min. direct voltage Max. inverse voltage Galvanic insulation Min. pulse duration Max number of operations Memory size Certification UL 61010-1 30 V DC 10 V DC 30 V DC 3 kV 1s 108 512 ko N° file : E25 7746 GLOSSARY OF ABBREVIATIONS MEMO P+ PQ+ QYES NO TOP INT EXT tIME dAtA SAG HySt SWELL dAtE tIME Memory module Positive power consumption demand Active power consumption demand Positive reactive power consumption demand Negative reactive power consumption demand Yes No Synchronisation signal Internal External Synchronisation period Event storing Voltage dip Hysteresis Overvoltage days / months / years hours / minutes / seconds RUDOLF - Ref. : 876 588 A 169 RUDOLF - Ref. : 876 583 A - 09/05 DPA96A/AN The brand that adds value to every solution. 47 Yishun Industrial Park A Singapore 768724 SINGAPORE Tel : (65) 6756 0833 Fax : (65) 6756 2007 http://www.bridex.com.sg E-mail: [email protected] RUDOLFTM brandname is the registered trademark of Bridex Singapore Pte Ltd (a member of SMB United Groupe) in Singapore and other countries. Our policy is one continuous development and we therefore reserve the right to alter technical data without prior notice.