Download SM831150-00_14954.23 KB

Transcript
06-289 Virus_Washer-TM
8/31/06
2:19 PM
Page 1
Safety Precautions
Be sure to read the following important safety information for safe and correct use of the product.
The items listed here represent important information related to safety. The indicators and their
meanings are as shown below.
WARNING
Incorrect handling or use may result in death or serious injury to the user.
CAUTION
Incorrect handling or use may result in injury to the user, or in property damage.
“Do not disassemble”:
Indicates that
disassembly is prohibited.
“Required”: Indicates a
required action.
“Prohibited”: Indicates a
prohibited action.
“Unplug”: Indicates that the power
cord must be unplugged.
“Electric Shock Danger” (Located
on main unit): Indicates that there
is the danger of electric shock.
“Do not touch”:
Indicates that contact
is prohibited.
“Do not wet”: Indicates that contact
with water is prohibited.
WARNING
Do not disassemble or modify.
Do not apply water.
Do not insert foreign objects.
Do not attempt to disassemble for repair or to
modify this system. Doing so may result in
fire, electric shock, or injury.
For repairs, consult with the
dealer where the product was
purchased.
Do not
Do not soak this unit in water or apply water
to it.
Doing so may result in a short circuit and
electric shock.
Do not insert metal objects such as pins or
needles, or other foreign objects, into the
intake, outlet, or water tank installation port.
Doing so may result in injury due to
electric shock, or in abnormal
operation of the system.
Do not wet
disassemble
Unplug the power cord before
cleaning or servicing the system.
When cleaning or servicing the system, be
sure to first unplug the power cord.
Failure to do so may result in
electric shock or injury.
Do not damage the power cord.
Do not scratch, cut, modify, bend excessively,
pull on, twist, or otherwise damage the power
cord.
Damage to the power cord may
result in fire or electric shock.
Unplug
Do not use with any power other
than 220 – 240 V AC power. Do
not plug multiple cords into the
same outlet.
Do not use chlorine-based or
acidic detergents when cleaning
the water tank, unit, or filters.
Acidic
These detergents
may result in
deformation and
discoloration.
Prohibited
Remove dirt or grim from the
power plug.
Regularly remove any dirt or grim from the
power plug.
If dirt or grim accumulates on the
power plug, humidity or other
factors may cause an insulation
Required
failure, resulting in fire.
Do not plug or unplug the power
cord with
wet hands.
Doing so may result
in electric shock.
Prohibited
Chlorinebased
Doing so may result in fire, electric
shock, or damage to the system.
Prohibited
Prohibited
Insert the power plug securely, all
the way to the base.
Do not use a plug that cannot be fully
inserted or that is damaged. Do not use a
loose power outlet.
Doing so may result in electric
shock or in fire caused by heating.
Prohibited
A leakage breaker is required.
Use a power source that includes a leakage
breaker.
Failure to do so may result in
electric shock or fire.
Required
Required
Do not use insecticides or
aromatics.
Do not use insecticides, aromatics, or
mosquito coils while the unit is
operating.
Doing so can cause system
malfunction.
Prohibited
CAUTION
Fill the water tank with new water every day.
Rinse out the water tank every day and keep it clean. Then be sure to
refill it with tap water.
If you continue to use the tank without
cleaning it, sediment and water scale may
decrease the performance of the unit,
or may cause the growth of mold or
Required
bacteria, resulting in odor.
To relocate the unit or store it (when it will not be
used for two weeks or longer), request servicing
by the dealer.
–1–
06-289 Virus_Washer-TM
8/31/06
2:19 PM
Page 2
Precautions
CAUTION
Do not place any containers that
contain liquid on top of the
system.
Doing so may result in system
malfunction.
Do not perform cleaning while the
system is operating.
Doing so may result in electric shock or
injury.
Prohibited
Grasp the power plug when
unplugging the power cord.
Using the unit without the water tank, filter, or
other component securely installed
may result in system malfunction.
When unplugging the power cord, do not
grasp the cord. Instead, be sure to grasp the
power plug at the end of the cord
and pull out the plug. Unplugging
the cord incorrectly may result in
Required
electric shock, short circuit, or fire.
Required
In a particularly cold environment, the freezeprevention function may be
activated, and the unit may not
operate even when the power
Required
switch is turned ON.
Do not install in a location
exposed to dripping water.
Doing so may result in system malfunction.
Prohibited
Do not obstruct the outlet with a curtain,
towel, or other item.
Doing so may result in system malfunction.
Prohibited
Be sure to securely reinstall all
components after cleaning.
Install the system indoors, and
use in an environment between
5°C and 30°C.
Do not obstruct the outlet.
Do not use the system with the
filter removed.
Dust entering into the system may cause
system malfunction.
Required
Avoid installation in high
locations. Install in a flat and
stable location.
Observe this precaution in order to ensure
that the system functions correctly.
Failure to do so may result in the
unit tipping over due to earthquake
or contact by persons.
Required
Prohibited
Do not place any items on the
unit.
Do not climb onto the unit.
Doing so may result in system
malfunction, or in the unit tipping
over.
Prohibited
Install in a location where there is
little humidity, cigarette smoke,
or other airborne substance.
Select a location for use which is free of humidity, dust,
cigarette smoke, incense smoke, oil smoke
(oil particles generated by food preparation),
salt, or ammonia. Failure to do so may result
Required
in odors or in system malfunction.
Secure space of 10 cm or more at
the left and right sides of the unit.
Also, allow servicing space of 100 cm or
more above and to the front of the unit.
Failure to do so may result in
system malfunction.
Required
Important information
Be sure to use normal tap
(drinking) water.
Never use water from a water purifier, water
from a water heater, alkali ion water, mineral
water, well water, seawater, or other types of
water. These types of water cannot be
electrolyzed and can cause the growth of
mold or bacteria, resulting in odor.
Perform regular cleaning.
Follow the instructions under “Cleaning the
System,” in order to clean and maintain the
unit.
If the unit becomes especially dirty, mold may
grow, resulting in odor.
Do not use tap water in regions
where the concentration of
chlorine ions in the tap water is
low, or in regions where the
chlorine concentration is high.
In some regions, the quality of the tap water
prevents the use of this product. For details,
consult with a dealer.
Do not direct the discharged air
directly onto walls or furniture.
Do not allow the discharged air to directly
contact walls or furniture.
It may damage the walls or furniture, resulting
in stains.
–2–
Do not unplug the power cord,
even if the unit will not be used
for a while.
Even when the unit is stopped, cleaning
inside the system is performed automatically.
Check that there is water in the water tank,
and do not unplug the power cord.
Be careful of freezing.
Freezing may result in system malfunction
and damage.
06-289 Virus_Washer-TM
8/31/06
2:19 PM
Page 3
Specifications
External
dimensions
1. Product Specifications
Model name
Commercial Space Cleaning System (Floor-Mounted)
Product No.
VW-VF8AG
mm
615
Width
mm
1,085
Depth
mm
230
Product weight
kg
40
Operating weight
kg
44 (when water tank is full)
Water tank capacity
L
Approx. 4
Exterior color (Munsell number)
–
Silky Shade (1 Y8.5 / 0.5)
Power source
–
Single-phase, 220 – 240 V, 50 / 60 Hz
Power cord length
m
1.5 (No ground)
Operating current
A
1.1 / 1.2
Power consumption
W
100 / 115
Power factor
%
91 / 96
–
Sirocco fan
Electrical
characteristics
Height
Fan
Model name
Qty.
1
Rated airflow
m3/min
Turbo: 8 / High: 5 / Standard: 3 *1
Motor output (No. of poles)
W
30 (4P)
Protective devices
–
Protective thermostat, fuse
Operating SW
–
Built-in unit control section
Service temperature
°C
5 – 30
Filters
–
Long-life filter (intake side)
Protective net (outlet side)
Operating noise
dB (A)
Turbo: 45 / High: 38 / Standard: 38 *2
Guide to water refill
hrs/refill
Turbo: Approx. 4 / High: Approx. 6 / Standard: Approx. 9 *3
Primary accessories
–
Tip-over prevention chain, User’s Manual, Installation Manual
When the fan speed is standard, the fan operates intermittently.
*1: The rated airflow for the standard fan speed is the average airflow during intermittent operation.
*2: The operating noise for the standard fan speed is the operating noise when the fan is operating during
intermittent operation.
*3: The guide to water refill is the number of hours at a room temperature of 20°C and 35% relative humidity.
*
The operating noise conforms to JIS standards, and was measured in an anechoic chamber. Therefore it is the
value at a position 1 m in front of the unit and a height of 1 m. When the unit is actually installed, ambient noise
and noise reflection ordinarily result in noise than the value indicated here.
–3–
06-289 Virus_Washer-TM
8/31/06
2:19 PM
Page 4
2. Part Specifications
G
Fan motor coil resistance
Model name
KUE4T-31CPZ
Blue – Brown
Resistance
Ω)
(Ω
29.91
Purple – Blue
9.00
Yellow – Purple
5.81
Yellow – Pink
G
14.96
Thermistor characteristics
Intake temperature sensor
70
65
60
55
Resistance [kΩ]
50
45
40
35
30
25
20
15
10
5
0
–30 –25 –20 –15 –10 –5
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70
Temperature [°C]
40
8
35
7
30
6
Resistance [kΩ]
Resistance [kΩ]
Electrolyzing unit water temperature sensor
25
20
15
5
4
3
10
2
5
1
0
–20 –15 –10 –5
0
5
10
15
0
20
Temperature [°C]
20
30
40
50
60
Temperature [°C]
3. Control Specifications
Microcomputer control: Settings:
Fan speed select (turbo, high, standard)
Service functions: Alarm display
–4–
TERMINAL
PLATE (3P)
1ø 230V
RED
BRN
GRN/YEL
GRN/YEL
YEL
VLT
BLU
GRY
GRY
RC
(BLU)
CR2
BLK
BLK
BLK
BLK
YEL
VLT
BLU
1 3 5 7 9
1 3
TRANS-S
(WHT)
FAN
(WHT)
T20
(GRY)
FAN
1
TR3
GRY
GRY
1 2 3 4 5 6
1 3
1 3
1 2
FS2 DP
(YEL) (BUL)
1 2
WTH TA
(RED) (YEL)
(GRN)
24VDEN
(WHT)
IC-Q
(WHT)
IND LAMP
(RED)
DENKYOKU
E
1 3
1 3 5
1 2 3 4 5 6
1 3
+
1 3
TRANS-P1 TRANS-S1 24VDEN
(YEL)
(WHT)
(GRN)
1
IC-Q 3
1 AC IN-1
(WHT) 5
5 (BLK)
GRN/YEL
E POWER
+ CONTROLLER
VW-VF8AG
5
7
4
5
6
RED
YEL
WHT
BLK
BLU
ORG
1 2 3 4 5 6 CONNECTOR
1 2 3 4 5 6 6P (WHT)
3
1
2
5
6
5
6
1
2
1
TA 2
TH1
TH2 F1, F2
1
ELECTRODE
1
DP
1
FS2
DENKYOKU 3
DP 3
2X
L
N
FMI
1
FS2 3
3X
RY006
1
IC-Q 3
2
5
RC
1
24VDEN 3
9
3
TR2
R
F2
1
IND
3 TRANS-P
AC 100V 1
S
RED
BRN
BRN
BRN
1 2
BRN
RED
ORG
WHT
WHT
BRN
1 3
RED
WHT
TR2
L H HH
3
8
1
2
IND 3 3
LAMP 4 4 IND
6
5
4 TRANS-S
3
WTH
2
1
AC
100V
RED
YEL
WHT
BLK
BLU
ORG
1 AC IN
3 (BLK)
AC
100V
BRN
3X
1
3 RC
49FI
2X
CONTROLLER
BRN
BRN
N
AC_IN
1
2
TR1
7
AC_OUT
BLK
BLK
PNK
BRN
BLK
BLK
1 3
T20 1
AC IN
1 3
BRN
BRN
RED
RED
ORG
ORG
WHT
WHT
1 3
BRN
BRN
AC
100V
TR3
DF
F1
1
N
1 3
TH2
FS2
S 1 2 3 4 5 6 7 8 CONNECTOR
P 1 2 3 4 5 6 7 8 8P (WHT)
PNK
BRN
BRN
CS
WHT
BLK
GRN/YEL
AC
100V
WHT
–5–
WHT
1 3
RS
TR1
CS
ELECTRODE
AC IN-1
S
5
POW
2
1 TRANS-S
3
3
AC 100V 1 TRANS-P
5
24VDEN 1
IC-Q 3
1
FMI
49FI
RC
TR1
TR2
TR3
FS2
DP
TH1
TH2
ELECTRODE
2X, 3X
RY006
CS
CR1
CR2
POW
IND
DESCRIPTION
INDOOR FAN MOTOR
INDOOR FAN MOTOR
RUNNING CAPACITOR
POWER TRANSFORMER
FLOAT SWITCH
DRAIN PUMP
THERMISTOR (WATER TEMP)
ROOM THERMISTOR
ELECTRODE
FUSE
AUXILIARY RELAY
CONTROL SWITCH
INDOOR CONTROLLER
FILTER CONTROLLER
POWER CONTROLLER
IND LAMP ASSY
TERMINAL PLATE
CONNECTOR
TERMINAL
Page 5
TH1
1 3
AC_IN
(BLK)
E
FILTER
+
CONTROLLER
AC_OUT
(WHT)
L
R
L1
FMI
GRN/YEL
L1 N
CR1
2:19 PM
SCHEMATIC DIAGRAM
8/31/06
8FA-2-5250-039-00-0
SYMBOLS
06-289 Virus_Washer-TM
ELECTRIC WIRING DIAGRAM
Circuit Diagram
1ø 230V