Download SM831150-00_14954.23 KB
Transcript
06-289 Virus_Washer-TM 8/31/06 2:19 PM Page 1 Safety Precautions Be sure to read the following important safety information for safe and correct use of the product. The items listed here represent important information related to safety. The indicators and their meanings are as shown below. WARNING Incorrect handling or use may result in death or serious injury to the user. CAUTION Incorrect handling or use may result in injury to the user, or in property damage. “Do not disassemble”: Indicates that disassembly is prohibited. “Required”: Indicates a required action. “Prohibited”: Indicates a prohibited action. “Unplug”: Indicates that the power cord must be unplugged. “Electric Shock Danger” (Located on main unit): Indicates that there is the danger of electric shock. “Do not touch”: Indicates that contact is prohibited. “Do not wet”: Indicates that contact with water is prohibited. WARNING Do not disassemble or modify. Do not apply water. Do not insert foreign objects. Do not attempt to disassemble for repair or to modify this system. Doing so may result in fire, electric shock, or injury. For repairs, consult with the dealer where the product was purchased. Do not Do not soak this unit in water or apply water to it. Doing so may result in a short circuit and electric shock. Do not insert metal objects such as pins or needles, or other foreign objects, into the intake, outlet, or water tank installation port. Doing so may result in injury due to electric shock, or in abnormal operation of the system. Do not wet disassemble Unplug the power cord before cleaning or servicing the system. When cleaning or servicing the system, be sure to first unplug the power cord. Failure to do so may result in electric shock or injury. Do not damage the power cord. Do not scratch, cut, modify, bend excessively, pull on, twist, or otherwise damage the power cord. Damage to the power cord may result in fire or electric shock. Unplug Do not use with any power other than 220 – 240 V AC power. Do not plug multiple cords into the same outlet. Do not use chlorine-based or acidic detergents when cleaning the water tank, unit, or filters. Acidic These detergents may result in deformation and discoloration. Prohibited Remove dirt or grim from the power plug. Regularly remove any dirt or grim from the power plug. If dirt or grim accumulates on the power plug, humidity or other factors may cause an insulation Required failure, resulting in fire. Do not plug or unplug the power cord with wet hands. Doing so may result in electric shock. Prohibited Chlorinebased Doing so may result in fire, electric shock, or damage to the system. Prohibited Prohibited Insert the power plug securely, all the way to the base. Do not use a plug that cannot be fully inserted or that is damaged. Do not use a loose power outlet. Doing so may result in electric shock or in fire caused by heating. Prohibited A leakage breaker is required. Use a power source that includes a leakage breaker. Failure to do so may result in electric shock or fire. Required Required Do not use insecticides or aromatics. Do not use insecticides, aromatics, or mosquito coils while the unit is operating. Doing so can cause system malfunction. Prohibited CAUTION Fill the water tank with new water every day. Rinse out the water tank every day and keep it clean. Then be sure to refill it with tap water. If you continue to use the tank without cleaning it, sediment and water scale may decrease the performance of the unit, or may cause the growth of mold or Required bacteria, resulting in odor. To relocate the unit or store it (when it will not be used for two weeks or longer), request servicing by the dealer. –1– 06-289 Virus_Washer-TM 8/31/06 2:19 PM Page 2 Precautions CAUTION Do not place any containers that contain liquid on top of the system. Doing so may result in system malfunction. Do not perform cleaning while the system is operating. Doing so may result in electric shock or injury. Prohibited Grasp the power plug when unplugging the power cord. Using the unit without the water tank, filter, or other component securely installed may result in system malfunction. When unplugging the power cord, do not grasp the cord. Instead, be sure to grasp the power plug at the end of the cord and pull out the plug. Unplugging the cord incorrectly may result in Required electric shock, short circuit, or fire. Required In a particularly cold environment, the freezeprevention function may be activated, and the unit may not operate even when the power Required switch is turned ON. Do not install in a location exposed to dripping water. Doing so may result in system malfunction. Prohibited Do not obstruct the outlet with a curtain, towel, or other item. Doing so may result in system malfunction. Prohibited Be sure to securely reinstall all components after cleaning. Install the system indoors, and use in an environment between 5°C and 30°C. Do not obstruct the outlet. Do not use the system with the filter removed. Dust entering into the system may cause system malfunction. Required Avoid installation in high locations. Install in a flat and stable location. Observe this precaution in order to ensure that the system functions correctly. Failure to do so may result in the unit tipping over due to earthquake or contact by persons. Required Prohibited Do not place any items on the unit. Do not climb onto the unit. Doing so may result in system malfunction, or in the unit tipping over. Prohibited Install in a location where there is little humidity, cigarette smoke, or other airborne substance. Select a location for use which is free of humidity, dust, cigarette smoke, incense smoke, oil smoke (oil particles generated by food preparation), salt, or ammonia. Failure to do so may result Required in odors or in system malfunction. Secure space of 10 cm or more at the left and right sides of the unit. Also, allow servicing space of 100 cm or more above and to the front of the unit. Failure to do so may result in system malfunction. Required Important information Be sure to use normal tap (drinking) water. Never use water from a water purifier, water from a water heater, alkali ion water, mineral water, well water, seawater, or other types of water. These types of water cannot be electrolyzed and can cause the growth of mold or bacteria, resulting in odor. Perform regular cleaning. Follow the instructions under “Cleaning the System,” in order to clean and maintain the unit. If the unit becomes especially dirty, mold may grow, resulting in odor. Do not use tap water in regions where the concentration of chlorine ions in the tap water is low, or in regions where the chlorine concentration is high. In some regions, the quality of the tap water prevents the use of this product. For details, consult with a dealer. Do not direct the discharged air directly onto walls or furniture. Do not allow the discharged air to directly contact walls or furniture. It may damage the walls or furniture, resulting in stains. –2– Do not unplug the power cord, even if the unit will not be used for a while. Even when the unit is stopped, cleaning inside the system is performed automatically. Check that there is water in the water tank, and do not unplug the power cord. Be careful of freezing. Freezing may result in system malfunction and damage. 06-289 Virus_Washer-TM 8/31/06 2:19 PM Page 3 Specifications External dimensions 1. Product Specifications Model name Commercial Space Cleaning System (Floor-Mounted) Product No. VW-VF8AG mm 615 Width mm 1,085 Depth mm 230 Product weight kg 40 Operating weight kg 44 (when water tank is full) Water tank capacity L Approx. 4 Exterior color (Munsell number) – Silky Shade (1 Y8.5 / 0.5) Power source – Single-phase, 220 – 240 V, 50 / 60 Hz Power cord length m 1.5 (No ground) Operating current A 1.1 / 1.2 Power consumption W 100 / 115 Power factor % 91 / 96 – Sirocco fan Electrical characteristics Height Fan Model name Qty. 1 Rated airflow m3/min Turbo: 8 / High: 5 / Standard: 3 *1 Motor output (No. of poles) W 30 (4P) Protective devices – Protective thermostat, fuse Operating SW – Built-in unit control section Service temperature °C 5 – 30 Filters – Long-life filter (intake side) Protective net (outlet side) Operating noise dB (A) Turbo: 45 / High: 38 / Standard: 38 *2 Guide to water refill hrs/refill Turbo: Approx. 4 / High: Approx. 6 / Standard: Approx. 9 *3 Primary accessories – Tip-over prevention chain, User’s Manual, Installation Manual When the fan speed is standard, the fan operates intermittently. *1: The rated airflow for the standard fan speed is the average airflow during intermittent operation. *2: The operating noise for the standard fan speed is the operating noise when the fan is operating during intermittent operation. *3: The guide to water refill is the number of hours at a room temperature of 20°C and 35% relative humidity. * The operating noise conforms to JIS standards, and was measured in an anechoic chamber. Therefore it is the value at a position 1 m in front of the unit and a height of 1 m. When the unit is actually installed, ambient noise and noise reflection ordinarily result in noise than the value indicated here. –3– 06-289 Virus_Washer-TM 8/31/06 2:19 PM Page 4 2. Part Specifications G Fan motor coil resistance Model name KUE4T-31CPZ Blue – Brown Resistance Ω) (Ω 29.91 Purple – Blue 9.00 Yellow – Purple 5.81 Yellow – Pink G 14.96 Thermistor characteristics Intake temperature sensor 70 65 60 55 Resistance [kΩ] 50 45 40 35 30 25 20 15 10 5 0 –30 –25 –20 –15 –10 –5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Temperature [°C] 40 8 35 7 30 6 Resistance [kΩ] Resistance [kΩ] Electrolyzing unit water temperature sensor 25 20 15 5 4 3 10 2 5 1 0 –20 –15 –10 –5 0 5 10 15 0 20 Temperature [°C] 20 30 40 50 60 Temperature [°C] 3. Control Specifications Microcomputer control: Settings: Fan speed select (turbo, high, standard) Service functions: Alarm display –4– TERMINAL PLATE (3P) 1ø 230V RED BRN GRN/YEL GRN/YEL YEL VLT BLU GRY GRY RC (BLU) CR2 BLK BLK BLK BLK YEL VLT BLU 1 3 5 7 9 1 3 TRANS-S (WHT) FAN (WHT) T20 (GRY) FAN 1 TR3 GRY GRY 1 2 3 4 5 6 1 3 1 3 1 2 FS2 DP (YEL) (BUL) 1 2 WTH TA (RED) (YEL) (GRN) 24VDEN (WHT) IC-Q (WHT) IND LAMP (RED) DENKYOKU E 1 3 1 3 5 1 2 3 4 5 6 1 3 + 1 3 TRANS-P1 TRANS-S1 24VDEN (YEL) (WHT) (GRN) 1 IC-Q 3 1 AC IN-1 (WHT) 5 5 (BLK) GRN/YEL E POWER + CONTROLLER VW-VF8AG 5 7 4 5 6 RED YEL WHT BLK BLU ORG 1 2 3 4 5 6 CONNECTOR 1 2 3 4 5 6 6P (WHT) 3 1 2 5 6 5 6 1 2 1 TA 2 TH1 TH2 F1, F2 1 ELECTRODE 1 DP 1 FS2 DENKYOKU 3 DP 3 2X L N FMI 1 FS2 3 3X RY006 1 IC-Q 3 2 5 RC 1 24VDEN 3 9 3 TR2 R F2 1 IND 3 TRANS-P AC 100V 1 S RED BRN BRN BRN 1 2 BRN RED ORG WHT WHT BRN 1 3 RED WHT TR2 L H HH 3 8 1 2 IND 3 3 LAMP 4 4 IND 6 5 4 TRANS-S 3 WTH 2 1 AC 100V RED YEL WHT BLK BLU ORG 1 AC IN 3 (BLK) AC 100V BRN 3X 1 3 RC 49FI 2X CONTROLLER BRN BRN N AC_IN 1 2 TR1 7 AC_OUT BLK BLK PNK BRN BLK BLK 1 3 T20 1 AC IN 1 3 BRN BRN RED RED ORG ORG WHT WHT 1 3 BRN BRN AC 100V TR3 DF F1 1 N 1 3 TH2 FS2 S 1 2 3 4 5 6 7 8 CONNECTOR P 1 2 3 4 5 6 7 8 8P (WHT) PNK BRN BRN CS WHT BLK GRN/YEL AC 100V WHT –5– WHT 1 3 RS TR1 CS ELECTRODE AC IN-1 S 5 POW 2 1 TRANS-S 3 3 AC 100V 1 TRANS-P 5 24VDEN 1 IC-Q 3 1 FMI 49FI RC TR1 TR2 TR3 FS2 DP TH1 TH2 ELECTRODE 2X, 3X RY006 CS CR1 CR2 POW IND DESCRIPTION INDOOR FAN MOTOR INDOOR FAN MOTOR RUNNING CAPACITOR POWER TRANSFORMER FLOAT SWITCH DRAIN PUMP THERMISTOR (WATER TEMP) ROOM THERMISTOR ELECTRODE FUSE AUXILIARY RELAY CONTROL SWITCH INDOOR CONTROLLER FILTER CONTROLLER POWER CONTROLLER IND LAMP ASSY TERMINAL PLATE CONNECTOR TERMINAL Page 5 TH1 1 3 AC_IN (BLK) E FILTER + CONTROLLER AC_OUT (WHT) L R L1 FMI GRN/YEL L1 N CR1 2:19 PM SCHEMATIC DIAGRAM 8/31/06 8FA-2-5250-039-00-0 SYMBOLS 06-289 Virus_Washer-TM ELECTRIC WIRING DIAGRAM Circuit Diagram 1ø 230V