Note 3: If the 2 power inputs are connected, the Switch will be powered from the highest connected voltage. The unit will alarm for loss of power, either PWR1 or PWR2. Note 4: To use the UL Listed LPS Power supply with output Rating 10.5-60 Vdc, minimum 2 A. Here, we recommended use DC 24V as the operating voltage. Note 5: Both of power inputs should apply with same electrical power system; mixing positive and negative electrical power system will make system damage. Note 6: Once power on the device, the system LED will activate by the sequence as table following: Indicators Stage 1 Stage 2 Stage 3 Stage 4 Stage 5 Stage 6 Power LED On On On On On On DI Off On Off Off Off Off DO Off Off On Off Off Off R.S. Off Off Off On Off Off SYS Off Off Off Off Off On Description Power on Ex. Booter Ld. firmware Ex. firmware System booting System Ready (Ex: executes; Ld: Load) By those LED indicators, we can know the exactly stage is performed by system during the power on. 9