Transcript
Racks & Intergrated Cabinets Integrated, Pre-Engineered Solutions Of Emerson Network Power For Computing In Europe Table Of Contents I n t r od u c t i on Page 3 Page Page 6 Page 8 Page 9 Bringing Market-Leading Data Center Technology To Your Business 4 A Perfect Solution – A Single Source One Face To The Customer Glossary of Terms System Sizing 1BHF 1BHF 1BHF 1BHF Page 18 Page 20 Page 22 Page 24 Page 26 4DFOBSJP" 3BDLT°/FUXPSL"DDFTT$MPTFU±4JOHMF1IBTF 4DFOBSJP# 3BDLT°/FUXPSL"DDFTT$MPTFU±4JOHMF1IBTF 4DFOBSJP$ 3BDLT°4NBMM%BUB3PPN±5ISFF1IBTF 4DFOBSJP% 3BDLT°4NBMM%BUB$FOUFS±5ISFF1IBTF Scenario&0QU 3BDLT°4NBMM%BUB$FOUFS±5ISFF1IBTF Scenario&0QU 3BDLT°4NBMM%BUB$FOUFS±5ISFF1IBTF Scenario F - Opt.1 3BDLT°.FEJVN%BUB$FOUFS±5ISFF1IBTF Scenario F - Opt.2 3BDLT°.FEJVN%BUB$FOUFS±5ISFF1IBTF Scenario F - Opt.3 3BDLT°.FEJVN%BUB$FOUFS±5ISFF1IBTF Page 28 Page 31 1BHF Page 38 Page 39 Page 40 Page 41 Knürr Miracel® and Knürr Miracel Plus® Server Rack Liebert MCR™ Mini Computer Room -JFCFSU9%'/™ Knürr CoolTherm® Knürr CoolAdd® Knürr RMS Compact II® Knürr ARC® (Admin Rack Console) 1BHF Page 45 1BHF 1BHF Page 56 1BHF -JFCFSU1PXFS4VSF™ PSI UPS Liebert GXT™ UPS -JFCFSU/9™ UPS (10-30 kVA) -JFCFSU/9™ UPS (40-200 kVA) Knürr Cable Management ,OSS%J4USJQ® S u r g e P r ot ec t i on Page 59 Liebert AccuVar® P r ec i s i on C ool i n g Page 61 Page 62 Page 65 Page 68 1BHF 1BHF 1BHF 1BHF 1BHF Precision Cooling Liebert HPM™ S Cooling Liebert HPM™ M-L Cooling Liebert XD™ Systems -JFCFSU9%$™ Coolant Chiller -JFCFSU9%7™ Cooling Module -JFCFSU9%)™ Cooling Module ,OSS$PPM-PPQ® ,OSS$PPM'MFY® 1BHF Page 83 Page 85 -JFCFSU/GPSN™4PGUXBSF Liebert MultiLink®"VUPNBUFE4IVUEPXO4PGUXBSF Liebert IntelliSlot™ Web Card 1BHF Page 88 Page 89 1BHF -JFCFSU4FSWJDFT Liebert Uptime Assurance Liebert Response &NFSTPO/FUXPSL1PXFS*OUFHSBUFE1SF&OHJOFFSFE4PMVUJPOT Solution Scenarios Ra c ks P ow er M on i t or i n g S er v i c e 2 For Many Decades, Emerson Network Power Has Been A Global Leader In The World Of Business-Critical Systems. The Best Run Companies Have Relied On Our Product Solutions, Technologies And Services Integrated solutions. Pre-engineered benefits. Energy efficient. 0OMZ&NFSTPO/FUXPSL1PXFSDPVQMFEXJUI,OSSBOE other dvisions can offer you the advantages of having a GVMMZJOUFHSBUFE°BOEQSFFOHJOFFSFE°TPMVUJPOGSPNSBDL to room. By consolidating all your products and services XJUIVTZPVBSFBTTVSFEUIBUFWFSZUIJOHXPSLTUPHFUIFS as one configured system. Reliability±1SPWFONJTTJPODSJUJDBMUFDIOPMPHJFTUIBU minimize single points of failure produce the highest posTJCMFSFMJBCJMJUZGPSZPVS*5TZTUFNTTPZPVDBOXPSLJO Bringing Market-Leading Data Center Technology To Your Business. Business information is more critical than ever to organizations of any size. All Data Centers are critical to their organizations. Likewise, they all face the same protection issues. Rising heat densities. More demand for reliable power. Ever-changing technologies. Cost and floor space restrictions. 8JUI,OSSBOE-JFCFSUFWFSZUIJOHGSPNTNBMM closets and computer rooms to centralized global Data Centers can capitalize on products and services designed for their individual needs. #BTFEPOVOJRVFOFFETPGWBSJPVT%BUB$FOUFSTXF BT&NFSTPO/FUXPSL1PXFSJOUFHSBUFESBDLTZTUFNTXJUIUIFSNBMNBOBHFNFOUQPXFSDPPMJOH monitoring and service as a pre-engineered soluUJPO1MVTXFPGGFSPQUJPOBMTFSWJDFTBOEMPDBMFYpertise and support that make our solution easy to confidence. Single Source±0OFTPVSDFUPTFMFDUDPOGJHVSFJOTUBMMBOETFSWJDFBMMZPVSQSPEVDUTBOEUFDIOPMPHJFTXJUI a single call to make. Integration±'SPNSBDLUPSPPNPVSQSPEVDUT and services form a holistic system. With our name on FBDIPVSQSFFOHJOFFSFEQSPEVDUTBSFNFBOUUPXPSLUPgether. Technical Support±-PDBMBOEGBDUPSZTVQQPSU by application specialists is available if needed. We as EmFSTPO/FUXPSL1PXFSBMTPIBWFUIFMBSHFTUUFBNPGGBDtory-trained Customer Engineers across the globe to provide you the breadth and depth needed to guarantee VQUJNFBTTVSBODFBOEEPXOUJNFSFDPWFSZ Flexible Configurability±"TZPVS*5SFRVJSFNFOUT DIBOHFPVSQSPEVDUTBOEUFDIOPMPHJFTQSPWJEFBOBEBQUable and cost-effective path to support synchronized HSPXUITPZPVµSFOPUTUVDLXJUIUIFVOFYQFDUFE Energy Efficiency±*UIBTBMXBZTCFFOPVSDPNNJUNFOUUPPVSDVTUPNFSTXIJDIJTXIZXFBSFBCMFUPPGGFS ´(SFFO*5µTPMVUJPOTUIBUIBWFCFDPNFUIFCFODINBSLJO the ICT market. The end result? A Data Center infrastrucUVSFXJUIUIFBCJMJUZUPBOUJDJQBUFBOEBEBQUUPDIBOHF 3 A Perfect Solution – A Single Source Solutions Of Emerson Network Power Give Your MissionCritical Network The Flexibility To Deal With Uncertainty Our pre-engineered solutions QSPNJTFGMFYJCJMJUZBOEBWBJMBCJMJUZ 8JUIUIFXJEFTUSBOHFPGQSPEVDUT JOUIFNBSLFUQMBDFXFDBOQSPWJEF NBYJNVNGMFYJCJMJUZUPNFFUUIF most stringent demands. 8FBSFBTJOHMFHMPCBMTPVSDFXJUI a long and successful legacy of protecting the operation of missioncritical systems. 0OMZ&NFSTPO/FUXPSL1PXFSDBO QSPWJEFZPVXJUI,OSSBOE-JFCFSU QSPEVDUTBTXFMMBTUIFTFSWJDFTZPV OFFECFGPSFEVSJOHBOEBGUFSUIF JOTUBMMBUJPOBOEUIFQFBDFPGNJOE you deserve. 8JUIUIFXJEFTUSBOHFPGQSPEVDUT JOUIFNBSLFUQMBDFXFDBOQSPWJEF NBYJNVNGMFYJCJMJUZUPNFFUUIF most stringent demands. 8FBSFBTJOHMFHMPCBMTPVSDFXJUI a long and successful legacy of protecting the operation of mission- critical systems. 0OMZ&NFSTPO/FUXPSL1PXFSDBO QSPWJEFZPVXJUI,OSSBOE-JFCFSU QSPEVDUTBTXFMMBTUIFTFSWJDFTZPV OFFECFGPSFEVSJOHBOEBGUFSUIF JOTUBMMBUJPOBOEUIFQFBDFPGNJOE you deserve. Surge Protection Uninterruptible Power Power Distribution Surge suppression protects ZPVS*5FRVJQNFOUBHBJOTU EBNBHJOHQPXFSTQJLFT±BOE from catastrophic failure. Availability depends on the DPOUJOVJUZPGQPXFSBOEUIF ability of an uninterruptible QPXFSTVQQMZUPSJEFUISPVHI outages and provide clean QPXFSUPTFOTJUJWF*5MPBET From the room level to the SBDLMFWFMEFMJWFSJOHBOE NBOBHJOHQPXFSUPFBDIJO QSPWJEJOHZPVUIFMPXFTUDPTU PGPXOFSTIJQ )PXJTUIJTQPTTJCMF Our pre-engineered solutions QSPNJTFGMFYJCJMJUZBOEBWBJMBCJMJUZ QSPWJEJOHZPVUIFMPXFTUDPTUPG PXOFSTIJQ )PXJTUIJTQPTTJCMF POWER 4 EJWJEVBMQJFDFPG*5IBSEXBSF is critical in ensuring availibility. ,OPXJOHXIBUJTIBQQFOJOHXJUIZPVSDSJUJDBMQPXFSBOEDPPMJOHFRVJQNFOU±BOEIBWJOHBVUPNBUFEQSP DFTTFTUPTIVUEPXOTFSWFSTJOBOPSEFSMZXBZJGSFRVJSFE±JTWJUBMUPTZTUFNSFMJBCJMJUZBOEVQUJNF MONITORING Rack Platform -JHIUXFJHIUFYUSVEFEBMVNJOVNGSBNFTXJUINPEVMBSDPOTUSVD UJPOPGGFSFBTZNPVOUJOHGPSBMM*5FRVJQNFOU5PPMMFTTBDDFTTPSZ mounting and a complete cable management system provide the most versatile platform available. COOLING Precision Cooling Active precision cooling provides precise temperature and humidity DPOUSPMBTXFMMBTBJSGJMUSBUJPOQSP UFDUJOHZPVSDSJUJDBMFRVJQNFOUGSPN heat and air impurities. SUPPORT SERVICES Offering the full spectrum of on-site support services including preventive maintenance. 5 One Face To The Customer Best-In-Class Technologies From A Single Source Center of Expertise: When you partner with Emerson Network Power for your Business-Critical Continuity™ needs across your enterprise, AC Power .JTTJPODSJUJDBMPQFSBUJPOTDBOµUHP EPXO8JUIBGVMMSBOHFPGVOJOUFS SVQUJCMF"$QPXFSTZTUFNTBOE BTTPDJBUFEQPXFSEJTUSJCVUJPOBOE FODMPTVSFTGSPNJOEJWJEVBMQSPEVDUT UPJOUFHSBUFETZTUFNTXFLFFQ%BUB Centers up and running. you benefit from not only Knürr and Liebert products and support, but also from the protection your technology infrastructure receives. Connectivity ,FFQJOHZPVSWPJDFWJEFPBOE EBUBGMPXJOHTNPPUIMZBOE RVJDLMZ We deliver connectivity TPMVUJPOTUISPVHIBGVMM line of products that safeHVBSEOFUXPSLSFMJBCJMJUZ DC Power Supporting voice and communication OFUXPSLTXJUIEFQFOEBCMF%$QPXFS 8FµWFCVJMUB%$1PXFSUFDIOPMPHZ QMBUGPSNUIFOFYUHFOFSBUJPOHMPCBM technology platform that delivers the NPTUSJHPSPVTOFUXPSLQPXFSBQQMJ DBUJPOTXJUI%$QPXFSEJTUSJCVUJPO control and monitoring systems. 6 Embedded Computing 3FEVDJOHUJNFUPNBSLFUBOETPG5XBSF development costs for the telecom industry. We deliver compreIFOTJWFIJHIMZJOUFHSBUFE platGPSNTPMVUJPOTUIBUESBX POPVSEFFQFYQFSUJTFQMVT a full line of products that bring real competitive advantage. Embedded Power .BLJOHQPXFSDPOWFSTJPOFBTZGPS *5BOEDPNNVOJDBUJPOTFRVJQNFOU We deliver a broad offering of soluUJPOTJODMVEJOH"$%$BOE%$%$ QPXFSTVQQMJFTBEBQUFSTDIBSHFST BOEQPXFSBDDFTTPSJFT Monitoring .BOBHJOHDSJUJDBMFRVJQNFOUBDUJWJUZBU multiple sites and site monitoring around UIFDMPDL°XJUIYSFNPUF and self-monitoring systems and services that provide continuous oversight of %BUB$FOUFSTBTXFMMBTXJSF MFTTXJSFMJOF and enterprise telecom applications. Outside Plant 1SPUFDUJOHBOENPWJOHWPJDFWJEFP and data electronics from the central office closer to the subscriber or optimizing cellsite infrastructure. 8FEFMJWFSBGVMMMJOFPGFODMPTVSFT cabinets and shelters that meet the OFUXPSLFEXPSMEµTEFNBOETGPSIJHI TQFFEXJUIPVUJOUFSSVQUJPO Power Switching & Controls Safeguarding facilities from operational disruption in case of electrical abnormality. We deliver QPXFSUSBOTGFSTXJUDIFT GPSBOPOTJUFQPXFSTPVSDF UIBUFOTVSFTQPXFSDPOUJOVJUZ for sensitive communications BOEEBUBQSPDFTTJOHFMFDUSPOJDT XIJMFQSPWJEJOHJODSFBTFEQPXFSDPOUSPM High Density Cooling Maintaining precise temperature for SFMJBCMFFRVJQNFOUQFSGPSNBODF8F deliver “chip-to-room cooling”– the most comprehensive range of precision- and IJHIEFOTJUZDPPMJOHTPMVUJPOTXIJDI protect mission-critical applications from even a slightest increase in temperature. Racks & Integrated Cabinets Optimizing technology and performance needs for indoor IT applications. We deliver standard and customized integrated cabinet solutions that NFFUVOJRVFBOETQFDJGJDOFFET for computer rooms of all sizes to integrated enclosures that include TFMGDPOUBJOFEBJSDPOEJUJPOJOH614BOEXJ SJOHNBOBHFNFOUJOBTUVSEZMPDLBCMFDB binet. Services %FMJWFSJOHOFUXPSLSFMJBCMFQSPHSBNT backed by the largest global services organization in the industry. 8FFODPNQBTTFOHJOFFSJOHJOTUBMMB UJPOQSPKFDUNBOBHFNFOUBOEUPUBMPO site PQFSBUJPOTNBOBHFNFOUQSFWFOUJWF maintenance and energy-consumptionmonitoring. Surge Protection %FGFOEJOHQPXFSWPJDFBOEEBUBJOB OFUXPSLBHBJOTUHSJEJSSFHVMBSJUJFTBOE dangerous electrical disturbances. 8FPGGFSQSPEVDUTPMVUJPOTXIJDI QSPWJEFQPXFSQSPUFDUJPOUPSFEVDF EPXOUJNFTBWFDSVDJBMNBOIPVST BOEFYUFOEFRVJQNFOUMJGF Glossary Of Terms Adaptive Architecture Industry Terms Power Cooling Liebert Adaptive Architecture™ Liebert Adaptive Architecture is a family of products and technologies that demonstrate the ultimate in GMFYJCJMJUZXIJMFCBMBODJOHUIFJNQPStance of minimal TCO and high availability. Availability When a proven technology or system design minimizes single QPJOUTPGGBJMVSFPSEPXOUJNFJO your IT systems. Power – Three Phase (EMEA) A three phase circuit consists of UISFFQIBTFTHSPVOEBOEJONPTU cases neutral. Typical three phase WPMUBHFTBSF77BOE7 Business-Critical Continuity The promise that our customFSTµUFDIOPMPHZJOGSBTUSVDUVSF XJMMOPUHPEPXOBOECSJOHUIFJS businesses to a standstill. Heat Rejection $PVOUFSJOHUIFJODSFBTFPGIFBUXJUIBJS cooled condensers and drycoolers for any ambient temperature or altitude. Hot air BOEXBUFSBSFSFNPWFEBOEUIFXBUFSJT cooled and recycled. Power – Single Phase (EMEA) 4JOHMFQIBTFDJSDVJUJTBUXPXJSF Precision Cooling DJSDVJUXJUIHSPVOE5ZQJDBMMZ7 The accurate controlling and regulation of 230V or 240V. UFNQFSBUVSFIVNJEJUZBOEBJSGJMUSBUJPO Open Architecture / Closed Architecture Open architecture is a cooling method that utilizes cooling coils and room air volume as a thermal TUPSBHFUPSJEFUISPVHIQPXFSPVUages. Closed architecture fully encloses UIFSBDLXJUIUIFDPPMJOHDPJMTJOTJEF 0UIFSQSPWJTJPOTBSFSFRVJSFEGPS QPXFSMPTTSJEFUISPVHI Redundancy -FWFMUPXIJDIBTZTUFNDBOTVTUBJOB GBJMVSFPSCFTFSWJDFEXIJMFDPOUJOVing to provide 100% of the product‘s intended function. 4ZTUFNTXJUIOPSFEVOEBODZNBZ TUPQGVODUJPOJOHXIFOBOZTJOHMF component fails or maintenance is SFRVJSFE Redundancy can be achieved by QBSBMMFMJOHDPNQPOFOUTXIFSFBU least one of the components is FYUSBBOEOPUSFRVJSFEGPSUIFTZTtem to provide 100% functionality. 5IJTEFTJHOQSFWFOUTNBKPSDPNponent failures or scheduled maintenance from affecting the performance of the product. This configuration can provide very high systems availability. The highest levels of redundancy BSFBDIJFWFECZJOTUBMMJOHUXPJOEFQFOEFOUTZTUFNTQSFGFSBCMZ XJUIJTPMBUFEJOQVUBOEPVUQVU paths. Preventive maintenance or any component failure has no affect on system performance because the second system is capable of providing 100% of the product‘s intended function. 8 Flexibility Products or systems that can be reconfigured or added to meet UIFEFNBOETPGOFXUFDIOPMPHJFTBDIJFWFIJHIFSQSPUFDUJPO SFTVMUTBOEBEBQUUPHSPXUI DIBOHJOHCVTJOFTTSFRVJSFments. Total Cost Of Ownership Cost evaluation based on sum PGFRVJQNFOUQVSDIBTFGVUVSF DIBOHFTBOETFSWJDFDPTUT Power Density .PSFQPXFS.PSFIFBU-FTT space. With the increase of procesTPSDBQBCJMJUJFTXJUIJOTNBMMFS TQBDFTQPXFSEFOTJUJFTXJMMBMTP rise (sometimes from 50Watt per TRNUPPWFS8BUUQFSTRN 5IJTNBLFTZPVSEBUBDFOUFSIPUUFS at times creating localized “hot spots.” Hot Aisle / Cold Aisle A highly recommended method of imQSPWJOHQFSGPSNBODFPGFYJTUJOHSBJTFE floor cooling technology in high density SBDLCBTFEBQQMJDBUJPOT3PXTPGFRVJQment racks are arranged in alternating “hot” and “cold” aisles. Only the cold BJTMFTIBWFQFSGPSBUFEGMPPSUJMFTUIBUBMMPX cool air to come up from under the raised floor. UPS Type – On-line or Line-Interactive An online UPS is used in the protection of critical applications and conTJTUTPGBDPOUJOVPVTGMPXPGQPXFS UIBUQSPUFDUTGSPNBMMQPXFSEJTUVSCBODFTJODMVEJOHTVCUMFIBSNPOJDT BOEXBWFGPSNEJTUPSUJPO"MJOFJOteractive UPS offers protection to SJEFPVU²EJSUZ³QPXFS5IJTFOFSHZ efficient technology provides both QPXFSDPOEJUJPOJOHBOECBUUFSZ back-up and is particularly effective XIFSFPVUBHFTBSFSBSFCVUQPXFS fluctuations are common. Sensible Heat Sensible heat is heat that can be felt or measured. It is the heat that causes a change in the temperature of a substance. Think of it as the temperature that the XFBUIFSNBOHJWFT*UDBOCFNFBTVSFECZ a thermometer. Servers give off strictly sensible heat. Battery Capacity 5IFQFSDFOUBHFPGQPXFSZPVHFU GSPNZPVSCBUUFSJFTBUUSJCVUFEUP BHFVTBHFFOWJSPONFOUUFNQFSBture and maintenance. A typical VRLA battery may reach 80% capacity and need replacement XJUIJOZFBST Battery Runtime The length of time (minutes) your CBUUFSJFTXJMMCBDLVQBOEQSPUFDU ZPVSJOGPSNBUJPOEVSJOHBQPXFS outage or system failure. kW 4UBOEBSEVOJUPGFMFDUSJDBMQPXFS FRVBMUPXBUUTPSBOFOFSHZ DPOTVNQUJPOSBUFPGKPVMFT QFSTFDPOEXIFSFKPVMFJTUIF BNPVOUPGFOFSHZSFRVJSFEUPSBJTF UIFUFNQFSBUVSFPGLHPGXBUFSCZ 1°C) Latent Heat Latent heat relates to the heat energy absorbed in the process of changing the form of a substance. In the air-conditionJOHDPPMJOHQSPDFTTMBUFOUIFBUSFNPWBMJT UIFDPOEFOTBUJPOPGWBQPSJOUIFBJSXIFO JUJTDPPMFECFMPXJUTEFXQPJOUEFIVNJEJfication). Removing latent heat does not affect the actual temperature that you feel. Total Heat Total heat is the sum of the heat content PGUIFBJSTFOTJCMFIFBU BOEUIFXBUFS WBQPSNJYMBUFOUIFBU *UUSBOTMBUFTUPUIF rated capacity of the air-conditioner. BTU #56JTEFGJOFEBTUIFVOJUPGIFBURVBOUJUZ SFRVJSFEUPDIBOHFUIFUFNQFSBUVSFPG POFQPVOEPGXBUFSEFHSFF'BISFOIFJU at sea level. One ton of air-conditioning = #56TQFSIPVS Cooling Tons A ton is the amount of heat removed by BOBJSDPOEJUJPOJOHTZTUFNUIBUXPVME melt 1 ton of ice in 24 hours. One refrigerBUJPOUPO#UVIL $BMPSJFTI System Sizing Sizing a critical power system to meet present and future needs is a fundamental requirement. Present Requirements Estimating the present system size in kilovolt amQFSFTL7" JTEPOFJOBOVNCFSPGXBZT5ZQJDBM TPVSDFTJODMVEFDPNQVUFSTJUFQMBOOJOHNBOVBMT FRVJQNFOUOBNFQMBUFEBUBBOEFMFDUSJDBMTFSWJDF EBUBL7"BOEL8SFRVJSFNFOUTBSFFTUJNBUFEVTJOH BOZPGUIFGPMMPXJOHGPSNVMBT 7WPMUT A = amperes L7"LJMPWPMUBNQFSFT L8LJMPXBUUT QGQPXFSGBDUPS #56IS#SJUJTI5IFSNBM6OJUTQFSIPVSIFBUPVUQVU ,DBMISLJMPDBMPSJFTQFSIPVSIFBUPVUQVU 1.1PXFSQSPGJMFPGFRVJQNFOU5IJTJTUIFNPTUSFMJBCMF CBTFGSPNXIJDIUPFTUJNBUFQSFTFOUL7"MPBEJOH For three-phase systems For single-phase equipment Where V is the line-to-lineVoltage L7"7 " 1000 "GUFSUIFQSFTFOUL7"SFRVJSFNFOUIBTCFFOEFUFSNJOFEUIFBOUJDJQBUFEHSPXUIBOEUIFTQFDJBMDIBSBDteristics of the load must be considered. Growth Requirements 5IFDSJUJDBMQPXFSTZTUFNTIPVMECFTJ[FEUPBOUJDJQBUF HSPXUI(SPXUISBUFTBTTPDJBUFEXJUIEBUBQSPDFTTJOH DFOUFSTEPVCMFQPXFSSFRVJSFNFOUTJOBTIPSUUJNF 5IFSFGPSFJUJTSFBTPOBCMFUPTJ[FUIFTZTUFNGPSUXJDF UIFQSFTFOUL7"MPBE&WFOJOBNJOJNVNHSPXUIFOWJSPONFOUUIFQPXFSTZTUFNTIPVMECFTJ[FEGPSPG the estimated kVA load. Special Load Characteristics 'PSTQFDJBMMPBEDIBSBDUFSJTUJDTGBDUPSZBQQMJDBUJPOFOHJneers should be consulted for recommended system sizing. System Grounding Considerations 5IFHSPVOEJOHPGBOZQPXFSDPOEJUJPOJOHTZTUFNJTDSJUJcal to its performance. L7"7 " 1000 2.,JMPXBUUTL8 BOE1PXFS'BDUPSQG *GQGJTOPUHJWFOBTTVNF kVA = kW pf 3. Ampere specifications for the electrical service feeding the site (for three-phase systems). "L7"7 4.#56ISPS,DBMISTQFDJGJDBUJPOT JGQGJTOPULOPXOBTTVNF L7"#56IS LDBMIS 3413 860 kVA = kW pf 9 Scenario A 1-2 Racks — Network Access Closet Single Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario A Input Power Raised Floor kW Range Racks UPS tive Power Distribution Cooling Monitoring 230V - 1 phase No 1 - 3 kW 1-2 Liebert PowerSure PSI Line-Interac- Server Shutdown Surge Suppression Knürr Di-Strip® Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink - Solution: 'PSUIFSPPNJOOFFEPGBTJOHMFSBDLUIJTJTBOFYBNQMFPGUIF &NFSTPO/FUXPSL1PXFSTPMVUJPOZPVµMMOFFEUPQSPUFDUZPVS*5 FRVJQNFOU"WBJMBCMFJOOPOSFEVOEBOUBOESFEVOEBOUDPOGJHVSBUJPOTHFUFWFSZUIJOHZPVOFFEJOPOFSBDLNBOBHFEQPXFS TUSJQTVOJOUFSSVQUJCMFQPXFSSBDLCBTFEIFBUSFNPWBMNPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU° BMMQSFFOHJOFFSFEUPXPSLBTBTJOHMFDPIFTJWFTZTUFN Products: Knürr Rack Miracel® °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFS 83% ventilation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE *5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert PowerSure PSI UPS °"SBDLNPVOUFETJOHMFQIBTF line- interactive UPS that provides protection against input WPMUBHFGMVDUVBUJPOTBOEPVUBHFTJOUFSOBMCBUUFSJFTBEEJUJPOBM battery cabinets and remote communications. Liebert Nform Monitoring Software °/FUXPSL CBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNQPXFSDPPMJOH and monitoring. Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Use this suggested scenario to begin framing the protection that TVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM-Jebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 10 Knürr 19” Racks Miracel® Knürr Cable Management Knürr Di-Strip® Knürr RMS Compact II® page 28 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario A Knürr Cable Management Knürr Di-Strip® Liebert PowerSure PSI UPS Liebert Monitoring & Shutdown Installation, Support and Services page 42 page 78 page 87 Knürr Miracel® and MiracelPlus® Liebert PowerSure PSI UPS 11 Scenario B 1-2 Racks — Network Access Closet Single Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario B (Option 1) Input Power Raised Floor kW Range Racks UPS Power Distribution Cooling Monitoring Server Shutdown Surge Suppression 230V - 1 phase No up to 1.8 kW 1 Liebert GXT On-line Knürr Di-Strip® Liebert MCR Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink - Specifications Scenario B (Option 2) Input Power Raised Floor kW Range Racks UPS Power Distribution Cooling Monitoring 230V - 1 phase No up to 14 kW 1-2 Liebert GXT On-line single phase Knürr Di-Strip® Liebert XDFN three phase Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink - Server Shutdown Surge Suppression Solution: "DPTUFGGFDUJWFJOUFHSBUFEFODMPTVSFXJUITFMGDPOUBJOFEQSFDJTJPODPPMJOHVOJOUFSSVQUJCMFQPXFSNBOBHFEQPXFSTUSJQT NPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOE TVQQPSU°UIJTTPMVUJPOBMMPXTGPSFBTZJNQMFNFOUBUJPOPGZPVS DPPMJOHSFRVJSFNFOUTCZJOUFHSBUJOHBDUJWFQSFDJTJPODPPMJOHJOUP UIFSBDL°BMMQSFFOHJOFFSFEUPXPSLUPHFUIFS Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM Liebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 12 Products (Option 1): Liebert MCR Integrated Enclosure – An integrated rack and encloTVSFXJUIBDUJWFQSFDJTJPODPPMJOHEFTJHOFEUPFOTVSFUIFMPOHUFSN WJBCJMJUZPG*5FRVJQNFOU Knürr DI Strip °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFSXJUIJOUIF SBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE*5FRVJQment. Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert GXT UPS – A rack-mounted single-phase true on-line UPS UIBUPGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFSOBMEZOBNJDCZQBTTBOE remote communications. Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOH PGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQNFOU Liebert MultiLink Shutdown Software °"VUPNBUFETIVUEPXO TPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVTDIBOHFT Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUP BTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMMBTXPSMEDMBTT TFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOEDPPMJOHQSPEVDUT Products (Option 2): Liebert XDFN Integrated Enclosure °*OUFHSBUFEFRVJQNFOUDBCJOFUXJUICVJMUJODPPMJOHQPXFSEJTUSJCVUJPOSBDLTNPOJUPSJOHBOE GJSFFYUJOHVJTITZTUFNPGGFSJOHGVMMSFEVOEBODZBOECBDLVQWFOUJMBUJPO Knürr DI-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFSXJUIJO UIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE*5 FRVJQNFOU Liebert GXT UPS – A rack-mounted single-phase true on-line UPS UIBUPGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFSOBMEZOBNJDCZQBTTBOE remote communications. Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOH PGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQNFOU Liebert MultiLink Shutdown Software °"VUPNBUFETPGUXBSFGPS PSEFSMZTIVUEPXOPGTFSWFSTCBTFEPODPOGJHVSBCMFSFTQPOTFT from UPS. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUP BTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMMBTXPSME DMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOEDPPMJOHQSPEVDUT Liebert Foundation MRCTM Knürr Cable Management Knürr Di-Strip® Knürr RMS Compact II® page 31 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario B Knürr Cable Management Liebert XDFN Rack Module Knürr Di-Strip® Option 1: Liebert XDFN Cooling Module Option 2: Liebert GXT UPS Liebert MCR enclosure with integrated cooling Liebert GXT UPS Liebert GXT UPS Liebert XDFN Liebert Monitoring & Shutdown Installation, Support and Services page 45 page 34 page 78 page 87 Liebert XDFN 13 Scenario C 3-6 Racks — Small Data Room Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario C Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling Monitoring 400V - 3 phase No 7 - 16 kW 3-6 Liebert GXT On-line Server Shutdown Surge Suppression Knürr Di-Strip® Liebert MicroPOD Liebert HPM S Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink - Solution: 'PSUIFSPPNXJUI°SBDLTUIJTTPMVUJPOQSPUFDUTZPVSTFSWFST OFUXPSLBOETUPSBHFFRVJQNFOU*OBEEJUJPOUPSBDLTNBOBHFE QPXFSTUSJQTVOJOUFSSVQUJCMFQPXFSNPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSUZPVµMMHFUSPPN based precision cooling from the most trusted name in the JOEVTUSZ°BMMQSFFOHJOFFSFEUPXPSLUPHFUIFS Use this suggested scenario to begin framing the protection that TVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM-Jebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 14 Products: Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJlation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE *5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert GXT UPS – A rack-mounted single-phase true online 614UIBUPGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPO JOUFSOBMCBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFSOBMEZnamic bypass and remote communications. Liebert MicroPOD °"MMPXTZPVUPNBOVBMMZUSBOTGFSZPVSDPOOFDUFEFRVJQNFOUUPVUJMJUZQPXFSWJBBNBJOUFOBODFCZQBTT TXJUDIQFSNJUUJOHTDIFEVMFENBJOUFOBODFPS614SFQMBDFNFOUXJUIPVUQPXFSEJTSVQUJPO Liebert HPM Precision Cooling – An active precision cooling TZTUFNQSPWJEJOHBWFSTBUJMFBOERVJFUSPPNTPMVUJPOJODMVEJOH UFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPXJOBOFYUSFNFMZ TNBMMGPPUQSJOUN2). Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQment Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Knürr 19” Racks Miracel® Knürr Cable Managment Knürr Di-Strip® Knürr RMS Compact II® page 31 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario C Liebert HPM Displacement Cooling Liebert GXT UPS Liebert MicroPOD Knürr MiracelPlus® Racks Liebert PowerSure PSI UPS Liebert MicroPOD Liebert HPM S Displacement Liebert Monitoring & Shutdown Installation, Support and Services page 42 page 55 page 62 page 78 page 87 15 Scenario D 7-10 Racks — Small Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario D Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling Monitoring 400V - 3 phase Optional 8 - 24 kW 7 - 10 Liebert NX On-line Server Shutdown Surge Suppression Knürr TriplePower® Included in UPS Liebert HPM S Displacement Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar 5IJTTPMVUJPOJTBMTPBWBJMBCMFXJUIVOEFSGMPPSBJSEJTUSJCVUJPO *OUIJTDBTFUIFTDFOBSJPXJMMVTF-JFCFSU)1.6UZQF Solution: 'PSUIFTFSWFSSPPNPSTNBMMEBUBDFOUFSPG°SBDLTUIJTJOOPWBUJWFBOESFMJBCMF&NFSTPO/FUXPSL1PXFSTPMVUJPOJTQFSGFDUGPS ZPVSOFFET8IFOJOGPSNBUJPOJTDSJUJDBMBOEEPXOUJNFJOFYDVTBCMFUIJTQSFFOHJOFFSFETPMVUJPOIBTUIFSFMJBCJMJUZZPVEFNBOE 3BDLTNBOBHFEQPXFSTUSJQTQSFDJTJPODPPMJOHVOJOUFSSVQUJCMF QPXFSBOEQPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOH TFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU° BMMQSFFOHJOFFSFEUPXPSLUPHFUIFS Use this suggested scenario to begin framing the protection that TVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM-Jebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 16 Products: Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJlation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE *5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJUPSing and remote communications. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision cooling TZTUFNQSPWJEJOHBWFSTBUJMFBOERVJFUSPPNTPMVUJPOJODMVEJOH UFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPXJOBOFYUSFNFMZ TNBMMGPPUQSJOUN2). Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQment. Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Knürr 19” Racks Miracel® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® page 31 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario D Liebert NX UPS Liebert HPM Displacement Cooling Knürr Miracel Plus® Racks Liebert NX UPS Liebert AccuVar page 49 page 59 Liebert HPM S Displacement Cooling page 62 Knürr Miracel Plus® Racks Knürr Di-Strip® Liebert Monitoring & Shutdown Installation, Support and Services page 78 page 87 Scenario E - Option 1 10-30 Racks — Small Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario E Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling Monitoring 400V - 3 phase Optional 36 - 72 kW 10 - 30 Liebert NX On-line Server Shutdown Surge Suppression Knürr TriplePower® Included in UPS Liebert HPM M Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar Solution: "TZPVSTZTUFNOFFETHSPXNPSFDPNQMFYXFIBWFUIFSJHIU solution for you. Designed specifically for the data center of °SBDLTUIJTFYBNQMFDPNCJOFTSBDLTNBOBHFEQPXFS TUSJQTFOFSHZFGGJDJFOUQSFDJTJPODPPMJOHVOJOUFSSVQUJCMFQPXFS QPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU° BMMQSFFOHJOFFSFEUPXPSLBTBDPIFTJWFTZTUFN Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM Liebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 18 Products: Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJlation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDL NPVOUFE*5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJtoring and remote communications. Liebert NX Battery Cabinet °&YUFOEFECBUUFSZDBCJOFUTBSF also available for longer back-up times. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision room DPPMJOHTZTUFNQSPWJEJOHBIJHIMZFOFSHZFGGJDJFOUTPMVUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPX Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQment. Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Knürr 19” Racks Miracel® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® page 31 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario E - Option 1 Liebert HPM M Cooling Knürr Miracel Plus® Racks Liebert HPM M Cooling Liebert NX UPS Liebert NX UPS Liebert AccuVar Liebert HPM M-L Cooling Liebert Monitoring & Shutdown Installation, Support and Services page 49 page 59 page 62 page 78 page 87 19 Scenario E - Option 2 10-30 Racks — Small Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario E Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling Monitoring 400V - 3 phase Optional 36 - 72 kW 10 - 30 Liebert NX On-line Server Shutdown Surge Suppression Knürr TriplePower® Included in UPS Liebert HPM M Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar Solution: "TZPVSTZTUFNOFFETHSPXNPSFDPNQMFYXFIBWFUIF right solution for you. Designed specifically for the data center of °SBDLTUIJTFYBNQMFDPNCJOFTSBDLTNBOBHFEQPXFS TUSJQTFOFSHZFGGJDJFOUQSFDJTJPODPPMJOHVOJOUFSSVQUJCMFQPXFS QPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU° BMMQSFFOHJOFFSFEUPXPSLBTBDPIFTJWFTZTUFN Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM Liebert or Knürr representative. For more detailed information about the Liebert and Knürr products in this Scenario, go to the pages indicated: 20 Products: Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJlation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDL NPVOUFE*5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJtoring and remote communications. Liebert NX Battery Cabinet °&YUFOEFECBUUFSZDBCJOFUTBSF also available for longer back-up times. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision room DPPMJOHTZTUFNQSPWJEJOHBIJHIMZFOFSHZFGGJDJFOUTPMVUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPX Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQment. Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Knürr 19” Racks Miracel® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® page 31 page 56 page 57 page 40 Knürr ARC (Admin Rack Console) and KVM Switches page 41 Scenario E - Option 2 Liebert HPM M Cooling Knürr Miracel® Racks Liebert HPM M Cooling Liebert NX UPS Liebert NX UPS Liebert AccuVar Liebert HPM M-L Cooling Liebert Monitoring & Shutdown Installation, Support and Services page 49 page 59 page 62 page 78 page 87 21 Scenario F - Option 1 30-60 Racks — Medium Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO Specifications Scenario F Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling - Room - High Density (Top of Rack) - High Density (in-line) - High Density Refrigerant Chiller Monitoring 400V - 3 phase Yes 72 - 144 kW 30 - 60 Liebert NX On-line Server Shutdown Surge Suppression Knürr Di-Strip® TriplePower® Included in UPS Liebert HPM M-L Liebert XDV Liebert XDH Liebert XDC Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar Solution: "TZPVSBQQMJDBUJPOHSPXTJOTJ[FUP°SBDLTBOEIFBU EFOTJUJFTSJTFUPVONBOBHFBCMFMFWFMT&NFSTPO/FUXPSL 1PXFSJTBCMFUPEFMJWFSBDVTUPNJ[FETPMVUJPOUIBUJTPQUJmized specifically for your needs. This system consists of SBDLTNBOBHFEQPXFSTUSJQTQSFDJTJPODPPMJOHFYUSFNF EFOTJUZSBDLDPPMJOHSFEVOEBOUVOJOUFSSVQUJCMFQPXFS QPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOHTFSWFS TIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU°OBUVSBMMZBMMQSFFOHJOFFSFEBTBTJOHMFTZTUFNUPNFFUZPVSDSJUJcal data protection needs. Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVS local Liebert or Knürr representative. Knürr 19” Racks Miracel® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® page 31 page 56 page 57 page 40 22 Products: Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJlation and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDL NPVOUFE*5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJUPSing and remote communications. Liebert NX Battery Cabinet °&YUFOEFECBUUFSZDBCJOFUTBSF also available for longer back-up times. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision room DPPMJOHTZTUFNQSPWJEJOHBIJHIMZFOFSHZFGGJDJFOUTPMVUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPX Liebert XDC High Density Refrigerant Chiller – Specifically designed to support the Liebert XDV and XDH high-density cooling system – circulates pumped refrigerant. Liebert XDV High Density Cooling °"GMFYJCMFIJHIEFOTJUZ spot and zone cooling system that mounts on the top of the SBDLUBLJOHVQ[FSPGMPPSTQBDF Liebert XDH High Density Cooling °"GMFYJCMFIJHIEFOTJUZ DPPMJOHTZTUFNUIBUTJUTJOMJOFXJUISBDLFODMPTVSFT Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQNFOU Liebert MultiLink Shutdown Software – Automated shutEPXOTPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVT changes. Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMM BTXPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOE cooling products. Knürr ARC (Admin Rack Console) and KVM Switches page 41 Liebert NX UPS Liebert NX Maintenance Bypass Cabinet Liebert NX Battery Cabinet page 49 page 55 page 55 Scenario F Option 1 Liebert NX UPS Liebert HPM Cooling Liebert XDV Liebert XDH Liebert XDC Knürr Miracel Plus® Racks Liebert AccuVar Liebert HPM Cooling Liebert XDC Liebert XDH Liebert XDV Liebert Monitoring & Shutdown Installation, Support and Services page 59 page 62 page 70 page 74 page 72 page 78 page 87 23 Scenario F - Option 2 30-60 Racks — Medium Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO To be updated Specifications Scenario F Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling - Room - High Density (Top of Rack) - High Density (in-line) - High Density Freecooling Chiller Monitoring 400V - 3 phase Yes 72 - 144 kW 30 - 60 Liebert NX On-line Server Shutdown Surge Suppression Knürr Di-Strip® TriplePower® Included in UPS Liebert HPM M-L Liebert XDV Liebert XDH Liebert HPC Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar Solution: "TZPVSBQQMJDBUJPOHSPXTJOTJ[FUP°SBDLTBOEIFBUEFOTJUJFTSJTFUPVONBOBHFBCMFMFWFMTXFBSFBCMFUPEFMJWFSBDVTUPNized solution that is optimized specifically for your needs. This TZTUFNDPOTJTUTPGSBDLTNBOBHFEQPXFSTUSJQTQSFDJTJPODPPMJOHFYUSFNFEFOTJUZSBDLDPPMJOHSFEVOEBOUVOJOUFSSVQUJCMF QPXFSQPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOHTFSWFS TIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDFBOETVQQPSU°OBUVSBMMZ all pre-engineered as a single system to meet your critical data protection needs. Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM Liebert or Knürr representative. Knürr Knürr 19” Racks & CoolAdd® Enclosures page 31 24 page 39 Products: Knürr CoolAdd® – The universal retrofit solution against overheating in server racks Knürr CoolTherm® 4–35 KW – Energy-efficient Server Cabinet 5FDIOPMPHZ8JUI0VUTUBOEJOH#FOFGJUT5P.JOJNJ[F&OFSHZ$PTUT *O5IF%BUB$FOUFS"OE)FMQ3FEVDF$BSCPO%JPYJEF&NNJTJPOT Knürr CoolLoop® – Side-mounted cabinets unit for highly efficient cooling in server cabinets from 10 to 30 kW – XJUITJHOJGJDBOUSFEVDUJPOTJOEBUBDFOUSFFOFSHZDPTUT Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJMBtion and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDL Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJUPSing and remote communications. Liebert NX Battery Cabinet °&YUFOEFECBUUFSZDBCJOFUTBSF also available for longer back-up times. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision room DPPMJOHTZTUFNQSPWJEJOHBIJHIMZFOFSHZFGGJDJFOUTPMVUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPX Liebert XDC High Density Refrigerant Chiller – Specifically designed to support the Liebert XDV and XDH high-density cooling system – circulates pumped refrigerant. Liebert XDV High Density Cooling °"GMFYJCMFIJHIEFOTJUZ spot and zone cooling system that mounts on the top of the SBDLUBLJOHVQ[FSPGMPPSTQBDF Liebert Nform Monitoring Software °/FUXPSLCBTFENPOJUPSJOHPGBMBSNOPUJGJDBUJPOTGSPNDPPMJOHBOEQPXFSFRVJQNFOU Liebert MultiLink Shutdown Software °"VUPNBUFETIVUEPXO TPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVTDIBOHFT Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMMBT XPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOEDPPMing products. Knürr CoolTherm® 4-35 KW Knürr CoolLoop® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® Liebert NX UPS page 38 page 75 page 56 page 57 page 40 page 49 Scenario F option 2 Liebert HPC Chiller Liebert HPM Cooling Liebert XDC Liebert NX UPS Knürr CoolTherm Liebert NX Maintenance Bypass Cabinet Liebert NX Battery Cabinet Liebert HPM Cooling Liebert XDC Liebert XDH Liebert XDV KVM, Monitoring & Shutdown Installation, Support and Services page 55 page 55 page 62 page 70 page 74 page 72 page 41/78 page 87 25 Scenario F - Option 3 30-60 Racks — Medium Data Center Three Phase 5IJTJTBOFYBNQMFPGBSFDPNNFOEFETPMVUJPO To be updated Specifications Scenario F Input Power Raised Floor kW Range Racks UPS Power Distribution - Power strips - Maintenance Bypass Cooling - Room - High Density (Top of Rack) - High Density (in-line) - High Density Freecooling Chiller Monitoring 400V - 3 phase Yes 72 - 144 kW 30 - 60 Liebert NX On-line Server Shutdown Surge Suppression Knürr Di-Strip® TriplePower® Included in UPS Liebert HPM M-L Liebert XDV Liebert XDH Liebert HPC Liebert Nform Knürr RMS Knürr ARC Knürr KVM Liebert MultiLink Liebert AccuVar Solution: "TZPVSBQQMJDBUJPOHSPXTJOTJ[FUP°SBDLTBOEIFBUEFOTJUJFTSJTFUPVONBOBHFBCMFMFWFMT&NFSTPO/FUXPSL1PXFSJTBCMF to deliver a customized solution that is optimized specifically for ZPVSOFFET5IJTTZTUFNDPOTJTUTPGSBDLTNBOBHFEQPXFS TUSJQTQSFDJTJPODPPMJOHFYUSFNFEFOTJUZSBDLDPPMJOHSFEVOEBOUVOJOUFSSVQUJCMFQPXFSQPXFSEJTUSJCVUJPOTVSHFTVQQSFTTJPONPOJUPSJOHTFSWFSTIVUEPXOTPGUXBSFJOTUBMMBUJPOTFSWJDF and support – all pre-engineered as a single system to meet your critical data protection needs. Use this suggested scenario to begin framing the protection UIBUTVJUTZPVSOFFET5PDPOGJHVSFBTPMVUJPODPOUBDUZPVSMPDBM Liebert or Knürr representative. Knürr Knürr 19” Racks & CoolAdd® Enclosures page 31 26 page 39 Products: Knürr CoolFlex® °&OFSHZFGGJDJFOUVTFPGFYJTUJOHDPPMJOH QPXFSJOEBUBDFOUFSTXJUIOFXJOTUBMMBUJPOTPSBTJOTUBMMBUJPO friendly upgrades for all brands. Knürr CoolAdd® – The universal retrofit solution against overheating in server racks Knürr CoolTherm® 4–35 KW – Energy-efficient Server Cabinet 5FDIOPMPHZ8JUI0VUTUBOEJOH#FOFGJUT5P.JOJNJ[F&OFSHZCosts *O5IF%BUB$FOUFS"OE)FMQ3FEVDF$BSCPO%JPYJEF&NNJTJPOT Knürr CoolLoop® – Side-mounted cabinets unit for highly efficient cooling in server cabinets from 10 to 30 kW – XJUITJHOJGJDBOUSFEVDUJPOTJOEBUBDFOUSFFOFSHZDPTUT Knürr Rack °-JHIUXFJHIUNPEVMBSSBDLTUIBUPGGFSWFOUJMBtion and simple add-on options. Knürr Cable Management – A full line of cable management BDDFTTPSJFTGPSFGGFDUJWFDPOUSPMPGBOZDBCMJOHSFRVJSFNFOUT Knürr Di-Strip® °%FTJHOFEUPEJTUSJCVUFBOENBOBHFQPXFS XJUIJOUIFSBDLBOENFFUUIFSFRVJSFNFOUTPGBOZSBDLNPVOUFE *5FRVJQNFOU Knürr RMS Compact II® °%BNBHFQSFWFOUJPOXJUIDIFDLT BOEDPOUSPMMT3BDLTFOTPSTGBOTQFFEUFNQFSBUVSFIVNJEJUZ TNPLFEFUFDUPSEPPSDPOUBDU Knürr ARC (Admin Rack Console) – a familie of 1U rack NPVOUBCMF-$%ESBXFST Knürr KVM Products °GPSBENJOJTUSBUJPONPOJUPSJOHDIFDLVQ and controlling. Liebert NX UPS – A compact three-phase true on-line UPS that PGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBM EZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTTTXJUDIJOUFSOBM CBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJUPSing and remote communications. Liebert NX Battery Cabinet °&YUFOEFECBUUFSZDBCJOFUTBSF also available for longer back-up times. Liebert AccuVar Surge Suppressor – Provides unparalleled protection from transient surges and electrical line noise. Liebert HPM Precision Cooling – An active precision room DPPMJOHTZTUFNQSPWJEJOHBIJHIMZFOFSHZFGGJDJFOUTPMVUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZGJMUSBUJPOBOEBJSGMPX Liebert XDC High Density Refrigerant Chiller – Specifically designed to support the Liebert XDV and XDH high-density cooling system – circulates pumped refrigerant. Liebert XDV High Density Cooling °"GMFYJCMFIJHIEFOTJUZ spot and zone cooling system that mounts on the top of the SBDLUBLJOHVQ[FSPGMPPSTQBDF Liebert MultiLink Shutdown Software °"VUPNBUFETIVUEPXO TPGUXBSFQFSNJUTDPOGJHVSBCMFSFTQPOTFTUP614TUBUVTDIBOHFT Installation & Support Services °6UJMJ[F-JFCFSUµTMPDBMFYQFSUJTFUPBTTJTUJOBTTFNCMJOHUVSOLFZJOTUBMMBUJPOTFSWJDFTBTXFMMBT XPSMEDMBTTTFSWJDFDPOUSBDUTGPSBMMPG-JFCFSUµTQPXFSBOEDPPMing products. Knürr CoolTherm® 4-35 KW Knürr CoolLoop® Knürr Cable Managment Knürr Di-Strip® TriplePower® Knürr RMS Compact II® Liebert NX UPS page 38 page 75 page 56 page 57 page 40 page 49 Scenario F option 3 Liebert HPC Chiller Liebert HPM Cooling Liebert XDC Liebert NX UPS Knürr Miracel Plus® Racks Liebert NX Maintenance Bypass Cabinet Liebert NX Battery Cabinet Liebert HPM Cooling Liebert XDC Liebert XDH Liebert XDV KVM, Monitoring & Shutdown Installation, Support and Services page 55 page 55 page 62 page 70 page 74 page 72 page 41/78 page 87 Knürr Miracel® and Miracel Plus® Server Rack Scenario A 1-2 Racks Single Phase page 10 Scenario C 3-6 Racks Three Phase page 14 Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 5IJTVOJRVFNPEVMBSDPOTUSVDUJPOBMMPXTGPSGMFYJCMFNPVOUJOH PGBDDFTTPSJFTBTXFMMBTBDPNQMFUFDBCMFNBOBHFNFOUTZTUFN XJUIBOFYUFOTJWFSBOHFPGBDDFTTPSZDPNQPOFOUT5IFTFSWFS rails guarantee easy mounting of 19” servers of all types plus Knürr accessories. With fully perforated doors (83% open area) this enclosure is set VQGPSPQUJNBMUIFSNBMNBOBHFNFOU°GBSFYDFFEJOHTFSWFS0&. SFRVJSFNFOUTGPSFGGFDUJWFIFBUEJTTJQBUJPO Features & Benefits Flexibility: ■ ■ 1BUFOUFEBMVNJOVNFYUSVTJPODSFBUFT Higher Availability: ■ Simplified installation of components re- DIBOOFMTBMMPXJOHGPSFBTZNPVOUJOHBM- BDPNQMFUFTZTUFNQSPWJEJOHB EVDFTPWFSBMMJOTUBMMBUJPOUJNFSFEVDJOH NPSFDPNQMFUFBOEGMFYJCMFTPMVUJPO costs. for most applications. Cabinet and accessories designed as a ■ standard accessories. the adverse effects of heat on computer Complete cable management system OFFETBOESFRVJSFNFOUT 4UBOEBSEQPXFSTUSJQNPVOUJOHCSBDLFU BMMPXTQPXFSTUSJQTUPCFNPVOUFEWJSUVBMMZBOZXIFSFJOUIFDBCJOFU 28 ■ Logical cable management system reEVDFTPCTUSVDUJPOTUPBJSGMPXSFEVDJOH ■ 5IFQPXFSTUSJQDBOCFDPOWFOJFOUMZ NPVOUFEJOUIF[FSP6TQBDFNBLJOHJU more accessible for the user. /PTQFDJBMJ[FEDPNQPOFOUTOFDFTTBSZ reducing costs and lead times. ■ Using a standard cable management system eliminates the need for a special sys- FRVJQNFOU QSPWJEFTNBOBHFNFOUGPSUIFVTFSµT ■ ■ NPTUBOZXIFSFJOUIFDBCJOFU TZTUFNBMMPXJOHDVTUPNJ[BUJPOXJUI ■ Cabinet and accessory items designed as Lowest Total Cost Of Ownership: UFNSFEVDJOHDPTUT ■ .BYJNJ[FTUIFBNPVOUPGVTBCMFTQBDFJO UIFDBCJOFUVMUJNBUFMZSFEVDJOHDBCJOFU count. Frequently Asked Questions Question Resolution Your cabinet frame is manufactured from aluminum. Is that strong enough for a server cabinet? .BOZIJHIMPBEQSPEVDUTBSFNBEFGSPNBMVNJOVNCFDBVTFJUPGGFSTBTJHOJGJDBOUMZ MPXFSQSPEVDUXFJHIUJOUBOEFNXJUIBTUJGGTUSPOHGSBNF5IFTFQSPEVDUTJODMVEFBJSQMBOFTBVUPNPCJMFTBOETQBDFDSBGU"MVNJOVNQFSGPSNTWFSZXFMMJOIJHIXFJHIUMPBE applications. I have been using the same cabinet manufacturer for the past few years. Why would I consider switching to Knürr? One of the primary reasons users change brands is because a change in technology renEFSTUIFDVSSFOUDBCJOFUPCTPMFUF5IFCFTUFYBNQMFPGUIBUPWFSUIFQBTUGFXZFBSTJT EVFFJUIFSUPUIFEFQUIPGUIFDBCJOFUPSUIFBNPVOUPGBJSGMPXUISPVHIUIFDBCJOFU ,OSSPGGFSTDBCJOFUTJOTUBOEBSEEFQUITPG³BOE³CPUIXJUIEPPSTUIBUPGGFS PQFOBSFB°UIFIJHIFTUJOUIFJOEVTUSZ$PVQMFUIBUXJUIUIFFBTFPGXPSLJOHXJUIUIF What is unique about Knürr and the Miracel Plus® cabinet? #FTJEFTUIFMJHIUXFJHIUCVUTUSPOHBMVNJOVNGSBNF,OSSPGGFSTUIF54MPUDIBOOFMJO UIFGSBNF5IJT54MPUXJUIBTQSJOHOVUBMMPXTGPSDPNQPOFOUTUPCFNPVOUFEWJSUVBMMZ BOZXIFSFJOUIFDBCJOFU5IFTBNF54MPUBMTPBMMPXTGPSUIFFBTZNPVOUJOHPGUPPMMFTT cable management accessories. Competitive Advantage Knürr Miracel Plus® The Knürr Advantage Patented aluminum extruded frame that is 50 lbs lighter than corresponding steel cabinet 1BUFOUFEBMVNJOVNFYUSVEFEGSBNFUIBUJTMCTMJHIUFSUIBODPSSFTQPOEJOHsteel cabinet Patented channel allows for a spring nut to be installed virtually anywhere in the cabinet frame 5IFBCJMJUZUPIBWFBTQSJOHOVUJOTUBMMFEWJSUVBMMZBOZXIFSFJOGSBNFDIBOOFMBMMPXTGPSUIFHSFBUFTUGMFYJCJMJUZ JONPVOUJOHDPNQPOFOUT"MTPUIFDIBOOFMBMMPXTGPSUIFVTFPGUPPMMFTTDBCMFNBOBHFNFnt accessories. Wide accessory line, offering hundreds of accessory items 8JEFSBOHFPGTUBOEBSEBDDFTTPSZJUFNTBMMPXTGPS²DVTUPNJ[BUJPO³VTJOHTUBOEBSE accessory items. Full line of structured cable accessories, including tool-less cable management items Full line of cable management items make it easy to effectively route cables in cabinet. Tool-less items make the installation very user-friendly. 83% open perforated area 5IFNPSFPQFOBSFBBEPPSQSPWJEFTNFBOTBNVDIHSFBUFSBJSGMPXUISPVHIUIFDBCJOFUSFEVDJOH the buildup of heat. 29 Knürr Miracel® and Miracel Plus® Server Rack ® PLUS® Knürr Miracel Knürr Miracel Also available in RAL 7021 dark-grey Also available in RAL 7035 light-grey PLUS® Miracel 19”-rack system Miracel The Knürr system platform best-seller An additional asset for the innovation rack ® Installation dimensions in accordance with IEC 60297 and IEC 60917 6666 FH6XJUINNFYUFSOBMIFJHIU BOE6XJUINNBOENPCJMFQMJOUI - NPEVMFNPEVMFNPEVMFNPEVMFNN 8JEUINN³ NNNPEVMF Static load rating /GPSUIFTUBUJPOBSZWFSTJPO /XJUINPCJMFQMJOUI Convenient 180° door opening angle Air partitioning Available as an option Liebert OpenComms™ EM and Liebert OpenComms™ vEM-14 Controllers Liebert OpenComms EM controllers are OFUXPSLFOBCMFEEFWJDFTGPS NPOJUPSJOHUFNQFSBUVSFIVNJEJUZBOE contact closures inside critical FOWJSPONFOUTJODMVEJOHSBDLTBOETNBMM computer rooms. 30 19” heavy duty server rack Installation dimensions in accordance with IEC 60297 66 FH6XJUINNFYUFSOBMIFJHIUXJUIDBTUPST 8JEUINN³ Static load rating /GPSUIFTUBUJPOBSZWFSTJPO /XJUIDBTUPST Stability has been greatly improved by more stable FYUSVTJPOTBOESFJOGPSDFEDPSOFSKPJOUT Convenient %PPSBTTFNCMZXJUIPVUUPPMT Air partitioning Standard Liebert PowerSure™ PSI The most energy efficient UPS in its class XJUIBGBDUPSZJOTUBMMFE-JFCFSU*OUFMMJ4MPU 8FC$BSEGPSOFUXPSLDPNNVOJDBUJPOT "WBJMBCMFJOBOE VA ratings. Liebert GXT™ "GBVMUUPMFSBOUOFUXPSLFOBCMFE614 capable of delivering EBUBDFOUFSRVBMJUZQPXFSQSPUFDUJPOUP SBDLTBOETNBMMSPPNT"WBJMBCMFJO BOE7" Liebert Foundation MCR is featured in this Scenario: Liebert MCR™ Mini Computer Room Scenario B 1-2 Racks Single Phase page 12 The Liebert Foundation MCR is a self-contained rack enclosure sysUFNUIBUJODMVEFTBMPBETJ[FEQSFDJTJPODPPMJOHVOJUMPDBUFEBU UIFCPUUPNPGUIFFODMPTVSFXJUIUIFPQUJPOPGBUPQNPVOUEFTJHOTVQQMZJOHDPPMBJSUPTFOTJUJWFFRVJQNFOUPOBMMMFWFMT A back-up cooling system ensures environmental security. 1PXFSDBOCFTVQQMJFEBOEQSPUFDUFEUISPVHIBOPQUJPOBM-JFCFSU (95POMJOF614PS-JFCFSU1PXFS4VSF14*MJOFJOUFSBDUJWF614 Features & Benefits Flexibility: ■ Designed as a plug-and-play system Higher Availability: ■ ready to install. ■ Wheel-mounted cabinet for easy reloca- "EKVTUBCMFSBDLTBOESBDLSBJMTTVQQPSUB ■ ■ BMMPXTNBYJNVNVTFPGJOUFSOBMSBDL DBQBDJUZXJUIUIFJOUFSOBMQSFDJTJPODPPM- ■ ■ ducing costs. ■ Improved cable access and management JNQSPWFTBJSGMPXUPSFEVDFPWFSIFBUJOH PGQSPUFDUFE*5FRVJQNFOU Optional energy saver control saves NPOFZCZBMMPXJOHCBDLVQDPPMJOHUP Back-up cooling assures continued cool- operate as primary enclosure cooler. JOHJOUIFFWFOUPGBQPXFSMPTT ■ Simplified plug-and-play installation reEVDFTPWFSBMMJNQMFNFOUBUJPOUJNFSF- Specially designed door gasket and ing environment. space or can be used to double cooling ing unit. TZTUFNDPNQBSFEUPQVSDIBTJOHTFQB- sealed cable entrance ensure stable cool- Optional top mounted precision cooling Competitively priced as an integrated rate components. Lockable door protects against unauthorized access. XJEFWBSJFUZPGFRVJQNFOU ■ ■ time from overheating. tion. ■ $PPMT*5FRVJQNFOUUPFMJNJOBUFEPXO- Lowest Total Cost Of Ownership: ■ Integrated precision cooling reduces poUFOUJBMEPXOUJNFDPTUTCZBTTVSJOH proper system operation. 31 Liebert Foundation MCR is featured in this Scenario: Liebert MCR™ Mini Computer Room Scenario B 1-2 Racks Single Phase page 12 Specifications ENCLOSURE DIMENSIONS Overall Frame Dimensions Rack Adjustable Drack Depth Internal rack Height Width Deptht Height Internal Rack Width Adjustable Width B*** Model mm mm mm mm mm Max mm Min mm RACk U mm )%$4&6 1956 535 450 18.5 42 )%4&6 965 1956 535 450 26.5 42 )%$4&6 965 1956 450 26.5 42 )%4&6 965 1956 450 26.5 42 * Casters add 1.5” to overall height of frame = 2000mm. ** Side panels add 0.75” each to overall width of frame. *** Doors add 0.1” each to overall depth of frame, BCM option adds an additional 3.00” to overall depth of frame. **** Max dimension is for ex-factory configuration. Rails can be inverted to provide an additional 4.00” of adjustment. ***** EX Expansion system option available in 3 sizes, increases front and/or rear depth (nominal / actual): 2” / 2”; 4” / 3.85”; 6” / 5.5.” ECM (Environmental Cooling Module) PERFORMANCE DATA Rated Capacity Supported Load Height Width Depth Total Heat Rej. Input Power (1PH) Sound Model Number BTUH (Watts) BTUH (Watts) Max Ambient In (mm) - U In (mm) In (mm) BTUH (Watts) Volts Hertz FLA WSA OPD Plug LPa (1.5m) ECM1000L*-C60 2811 (824) '$ 120 60 8.6 15 /&."1 52 ECM2000L*-C60 '$ 10935 (3204) 120 60 9.8 15 /&."1 52 “* T (top mount) and R (rack mount). Top mount weight does not include interface plenum. The interface plenum for a 19”” rack x 30 “” deep cabinet is 38 lbs.” Sound data based on sound pressure A- weighted scale for free field spherical radiation at 1.5 meters from cabinet. Sound data reflects only rack mount design. Consult factory for top mount data. ECM (Environmental Cooling Module) PERFORMANCE DATA Rated Capacity Model Number BCM 1000L-60 BCM 2000L-60 Supported Load Height Width Depth Total Heat Rej. In (mm) In (mm) Sound BTUH (Watts) BTUH (Watts) Max Ambient In (mm) - U BTUH (Watts) Volts Hertz FLA WSA OPD LPa (1.5m) /" 2811 (824) '$ 35.0 (889) 3038 (890) 120 60 1.0 1.3 15 /" 2811 (824) '$ 35.0 (889) 120 60 2.0 2.5 15 59 Above BCM weight includes rear door weight of 17 Lbs. Sound data based on sound pressure A- weighted scale for free field spherical radiation at 1.5 meters from cabinet. 32 Input Power (1PH) Frequently Asked Questions Question Resolution Can’t I just buy a cabinet and put in an air conditioner? The Liebert Foundation MCR provides a complete solution. There is no need to purchase and install separate add-on components. The Liebert Foundation MCR is a self-contained TZTUFNSFBEZUPHPSJHIUGSPNUIFTUBSUXJUIDPNQPOFOUTUIBUBSFTQFDJGJDBMMZEFTJHOFE UPXPSLUPHFUIFS What if we decide to move our offices? 5IF-JFCFSU'PVOEBUJPO.$3JTNPVOUFEPOXIFFMTTPJUJTFBTZUPJOTUBMMBOESFMPDBUF +VTUQPTJUJPOUIFVOJUBOEIPPLJUVQGPSJOTUBMMBUJPO*UµTKVTUBTFBTZUPSFMPDBUFBTOFFET or room layouts change. What if we don’t have a special room for The Liebert Foundation MCR accommodates spaces not designed for cooling. It fits our computer system? UISPVHITUBOEBSETJ[FEEPPSXBZTBOEJTBJSDPPMFETPJUDBOPQFSBUFXJUIPVUBDDFTTUP DIJMMFEXBUFS Isn’t it going to get really hot inside that cabinet? The Liebert Foundation MCR includes computer-grade high availability precision cooling QMVTBCBDLVQDPPMJOHNPEVMFUIBUSFNPWFTIFBUJOUIFFWFOUPGBQPXFSPVUBHF Competitive Advantage Feature Liebert Foundation MCR Complete, self-contained unit *ODMVEFTSBDLDPPMJOHNPOJUPSing and control. The self-contained Liebert unit provides plug-and-play installaUJPOXJUIOPPOTJUFBTTFNCMZPSNFDIBOJDBMDPOOections reRVJSFE Cooling method Self-contained air cooled. 5IFTFMGDPOUBJOFEDPPMJOHTZTUFNEPFTOPUJOUSPEVDFXBUFS QJQJOHJOUPUIFSPPNPSJOUIFSBDLXJUIFRVJQNFOU'FBUVSFT MPXOPJTFPQFSBUJPOTVJUBCMFGPSVTF in occupied spaces. Fits through standard sized doorways Backup cooling module provides cooling during a MPTTPGVUJMJUZQPXFSPSIJHIJOUFSOBMUemperature conditions. Backup cooling module of the Liebert Foundation MCR ensures DPPMJOHJOFNFSHFODZDPOEJUJPOTGPSIJHIFSBWBJMBCJMJUZXJUIPVU UIFVTFPGTQSJOHMPBEFEEPPSTUIBUSFRVJSFBEEJUJPOBMTQBDF DMFBSBODFTBOENBZDPOGMJDUXJUITBGety codes or practices. Fits through standard sized doorways ³8Y³%Y³) Liebert Foundation MCR is designed to fit through standardTJ[FEEPPSXBZT Fan location Located at the bottom. -JFCFSU'PVOEBUJPO.$3QSPWJEFTJUTBJSDJSDVMBUJPODPPMJOH GVODUJPOFWFOXIFOUIFSFBSEPPr is open for service access. Airflow type Rear of unit. 5IFBJSGMPXQBUUFSOJOUIF-JFCFSU'PVOEBUJPO.$3QSPWJEFTB more uniform air circulation throughout the cabinet to prevent IPUTQPUTXJUIJOUIFFODMPTVSF 33 Liebert XDFN is featured in this Scenario: Liebert XDFN™ Scenario B 1-2 Racks Single Phase page 12 5IF-JFCFSU9%'/JTBOJOUFHSBUFEFRVJQNFOUDBCJOFUXJUICVJMUJO DPPMJOHQPXFSEJTUSJCVUJPOSBDLTGPSTFSWFSMPDBUJPONPOJUPSJOH BOEGJSFFYUJOHVJTITZTUFNPGGFSJOHGVMMSFEVOEBODZBOECBDLVQ WFOUJMBUJPO-JFCFSU9%'/JTEFTJHOFEJOPSEFSUPQSPWJEFDPPMJOH TZTUFNGPSTFSWFSTVQUPBCPVUL8NBYJNVNOFUDPPMJOH -JFCFSU9%'/QSPWJEFTBTBGFQSPUFDUJPOUPDVTUPNFSTTFSWFSTGSPN risks related to server over heating providing a complete solution GPSSFEVOEBODZQPXFSQSPUFDUJPOGJSFFYUJOHVJTICBDLVQWFOUJMBtion. *OPSEFSUPDPWFSEJGGFSFOUIFBUMPBETBOEOVNCFSPGSBDLTNVMUJQMFDPOGJHVSBUJPOTPS-JFCFSU9%'/BSFBWBJMBCMF Frequently Asked Questions Question Resolution What makes the Liebert XDFN the right choice? ■ *OOPWBUJWF%FTJHO5IF-JFCFSU9%'/JODMVEFTBEWBODFEGFBUVSFTOPUGPVOEJODPNQFUJOHTZTUFNTJODMVEJOH%JHJUBM4DSPMMDPPMJOHUFDIOPMPHZBEBQUJWFDPOUSPMTUIF CSPBEFTUTFMFDUJPOPGIFBUSFKFDUJPONFUIPET°BJSXBUFSHMZDPMBOEDIJMMFEXBUFS ■ "5PUBM4PMVUJPO#FDBVTFUIF-JFCFSU9%'/JTEFTJHOFEBTBOJOUFHSBUFETZTUFNJUIBT NPSFGMFYJCJMJUZGPSJOTUBMMBUJPOBOESFDPOGJHVSBUJPOUIBOBUSBEJUJPOBMDFJMJOHNPVOUFE DPPMJOHTZTUFNXJUIUIFBTTPDJBUFESBDLBOEEVDUXPSL ■ 4J[FE3JHIU-JFCFSU9%'/JTBWBJMBCMFJOTFWFSBMTJ[FTXJUIOFUDPPMJOHDBQBDJUZVQUP L8TPJTTVGGJDJFOUGPSNPTUSBDLFRVJQNFOUCFJOHEFQMPZFE ■ /FUXPSLDMPTFUTXJUIIJHIEFOTJUZTFSWFSTBOETXJUDIFT ■ 4NBMMEBUBDFOUFSTXJUIIJHIEFOTJUZTFSWFSEFQMPZNFOUTJODMVEJOH*%'TBOE.%'T ■ 8JSJOHDMPTFUTIPVTJOH7P*1TZTUFNTBOEPUIFSTFOTJUJWFFRVJQNFOU What are some of the best places to consider using the Liebert XDFN? Telecom shelters. ■ How difficult is installation? ■ .BOVGBDUVSJOHGBDJMJUJFTXJUISFNPUFNJTTJPODSJUJDBM*5FRVJQNFOU ■ 8BSFIPVTFTXJUI3'*%JOTUBMMBUJPOT ■ Eliminates high heat up to 25kW net per rack. 1SPWJEFT/SFEVOEBODZ ■ ■ Includes emergency ventilation in the event of an unplaOOFETIVUEPXO ■ Multiple configurations available. &BDISBDLVQUP6FRVJQNFOU ■ -PXFSFOFSHZDPTUTUISPVHIUIFVTFPGB%JHJUBM4DSPMMDPNQSFTTPSGPSDPOUJOVBMBOE QSFDJTFBEKVTUNFOUTJODPPMJOH ■ .VMUJQMFDPPMBOUPQUJPOTBJSXBUFSHMZDPMPSDIJMMFEXBUFS ■ &BTJMZBEBQUBCMFQMVHBOEQMBZJOTUBMMBUJPO4FMGDPOUBJOFE ■ 34 Liebetr XDFN Features & Benefits Flexibility: Lowest Total Cost Of Ownership: Flexibility Higher Availability: ■ "MMJOUFHSBUFEDPPMJOHQPXFSNPOJUPSing and other accessories are designed for optimum compatibility and factory tested to ensure operational integrity upon installation. ■ Integrated unit is plug-and-play and reRVJSFTKVTUFBTZPOTJUFBTTFNCMZ ■ Standard features reduce installation BOENBJOUFOBODFDPTUTBOEJODSFBTF uptime. ■ Standard integrated unit inDMVEFTSBDLT XJUIFYUSFNF EFOTJUZDPPMJOHTZTUFNXJUI built-in monitoring and control ■ Digital Scroll compressor ■ "MMPXTGPSDPOUJOVBMBOEQSFDJTFBEKVTUments in cooling to optimize environmental control and reduce threats to UIFJOUFHSJUZPGOFUXPSLFRVJQNFOU ■ Responds automatically to fluctuations JOIFBUPVUQVUGSPNSBDLFRVJQNFOU ■ More cost-effective than traditional DPPMJOHTZTUFNTXJUIMPXFSFOFSHZDPOTVNQUJPOBOEMFTTXFBSBOEUFBS ■ EC fan ■ /" ■ Soft start included. ■ -PXFSFOFSHZDPOTVNQUJPOSFTVMUJOHJO MPXFSPQFSBUJPODPTUT ■ Automatic “back up” ventilation ■ Uses room air for emergencies to proWJEFHSFBUFSSJEFUISPVHIXJUIHSFBUFS cooling capacity. ■ $BOCFJOTUBMMFEXJUIPVUQPXFSCBDLVQ for cooling. ■ Increased availability eliminates costly EPXOUJNF ■ Standard height and depth ■ /" ■ ³XJEUIBOE³IFJHIUBMMPXUIFVOJU UPGJUUISPVHITUBOEBSETJ[FEEPPSXBZT ■ Standard size eliminates the need for TQFDJBMJOTUBMMBUJPOXPSL ■ Intelligent controls ■ Liebert iCOM control system ensures TZTUFNNBJOUFOBODFBOEXFMMOFTTCZ monitoring the cooling system and environmental conditions. ■ iCOM can be monitored locally and via remote access. ■ The ability to anticipate and detect system status helps to ensure uptime and reduce the cost of system administration. ■ Front to back air circulation ■ 1SPWJEFTVOJGPSNBJSGMPXUISPVHIPVU the cabinet to ensure better cooling for BMMFRVJQNFOUXJUIJOUIFSBDL ■ &OBCMFTTFSWFSTUPCFJOTUBMMFEBOZXIFSF XJUIJOUIFSBDLBOETUJMMSFDFJWFVOJGPSN cooling. ■ Reduces operating costs through increased uptime and less likelihood of FRVJQNFOUEBNBHF ■ 0QUJPOBMJOUFHSBUFEQPXFSEJTUSJbution ■ Knürr Di-Strip® are also available as an JOTUBMMFEPQUJPOGPSJNQSPWFEFRVJQNFOUQPXFSDPOUSPM ■ Provides the ability to monitor and conUSPMQPXFSBUUIFSFDFQUBDMFMFWFM ■ .PSFFGGJDJFOUDPOUSPMPGFRVJQNFOU saves energy costs and increases system uptime. ■ Built-in monitoring capability ■ Greater visibility and control of systems BOEDPOEJUJPOTXJUIJOUIFFODMPTVSFFOsure rapid notifications of potential problems affecting availability. ■ Options are available for connecting to Liebert remote monitoring devices or for standard Building Management SysUFNJOUFSGBDFTWJB4/.1 ■ Reduces the risk and associated costs of VOQMBOOFEEPXOUJNF ■ Optional UPS system ■ An optional Liebert GXT rack-mounted 614GFBUVSFTPOMJOFQPXFSQSPUFDUJPO SFNPUFNPOJUPSJOHBOFYUFSOBMNBJOUFOBODFCZQBTTBOEFYUFOEFECBUUFSZ runtimes. ■ 0GGFSTDPNQBDUIJHIBWBJMBCJMJUZQPXFS QSPUFDUJPOXJUIJOUIFFODMPTVSFJUTFMG ■ Ensures continuous system availability; SFEVDFTEPXOUJNFBOEBTTPDJBUFE costs. ■ Multiple cooling options ■ /" ■ $IPPTFCFUXFFOBJSDPPMFEXBUFSHMZDPMDPPMFEPSDIJMMFEXBUFSTZTUFNTUP BDDPNNPEBUFFYJTUJOHJOGSBTUSVDUVSF conditions. ■ &OTVSFTMPXFSJOTUBMMBUJPODPTUTDPNQBSFEUPTZTUFNTPGGFSJOHKVTUPOFUZQFPG cooling. 35 Liebert XDFN™ is featured in this Scenario: Liebert XDFN™ Scenario B 1-2 Racks Single Phase page 12 Competitive Advantage Feature Liebert Foundation MCR Liebert Advantage Complete, self-contained unit *ODMVEFTSBDLDPPMJOHNPOJUPSing and control. The self-contained Liebert unit provides plug-and-play installaUJPOXJUIFBTZPOTJUFBTTFNCMZBOENFDIBOJDBMDPOOections reRVJSFE Cooling method 5ISFFPQUJPOT "JSDPPMFEXJUISFNPUFDPOEFOTFS 8BUFSHMZDPMDPPMFE 3. Chilled Water-cooled .VMUJQMFPQUJPOTPOUIF-JFCFSU9%'/QSPWJEFHSFBUFSJOTUBMMBUJPO GMFYJCJMJUZBOEMPXFSDPTUPGPXOFSTIJQCZBMMPXJOHDVTUPNFSTUP BDDPNNPEBUFFYJTUJOHJOGSBTUSVDUVSFDPOEJUJPOT5IFBJSDPPMFE DPOEFOTFSWFSTJPOTEPOPUJOUSPEVDFXBUFSQJQJOHJOUPUIFSPPN or in the raDLXJUIFRVJQNFOU Backup ventilation capability Has emergency ventilation in case of unplanned TIVUEPXOBTFGGFDUJWFBTUIFQrimary cooling system. #BDLVQWFOUJMBUJPOPGUIF-JFCFSU9%'/TVQQPSUTHSFBUFSSJEF UISPVHIGPSIJHIFSBWBJMBCJMJUZXJUIPVUUIFVTFPGTQSJOHMPBEFE EPPSTUIBUSFRVJSFBEEJUJPOBMTQBDFDMFBSBODFTBOENBZDPOGMJDU XJUITBGFUZDPEFTPSQSBDUJDFT-JFCFSU9%'/JTEFTJHOFEUPGJU through sUBOEBSETJ[FEEPPSXBZT Fits through standard sized doorways Width PGUIFNPEVMFTNBYNN -JFCFSU9%'/JTEFTJHOFEUPGJUUISPVHI standard-sized doorXBZT Air circulation Bottom to top and front to back of the cabinet. -JFCFSU9%'/QSPWJEFTJUTBJSDJSDVMBUJPODPPMJOHGVODUJPOFWFO XIFOUIFGSPOUPSSFBSEPPr is open for service access. Nominal cooling capacity SeveralTJ[FTVQUPL8net sensible 5IF-JFCFSU9%'/DBQBDJUZJTTVGGJDJFOUGPSNPTUSBDLFRVJQNFOU being deployed. 36 Specifications PHYSICAL DATA Liebert XDFN X13UA Air Cooled )FJHIU8JEUI%FQIUPWFSBMM NN 8FJHIU$BCJOFU0OMZLH X20UA Air Cooled X25UC Chilled Water "MM 413 435 410 ELECTRICAL DATA 1PXFS4VQQMZ QI)[ 6OJU1PXFS*OQVUL8 4.38 6.46 'BOBCTPSCFEQPXFSL8 0.84 1.35 Fan FLA - A 1.36 2.2 Fan LRA - A 0.1 0.1 0.1 $PNQSFTTPSBCTPSCFEQPXFSL8 3.34 4.91 /" Compressor FLA - A 10 10.8 /" Compressor LRA - A 50 /" 3BUJOHQPJOU"NCJFOU$ 35 35 /" $IJMMFE8BUFS5FNQFSBUVSFQVSFXBUFS $ /" /" PERFORMANCES Supply Air Temperature - °C 22 22 22 /FU4FOTJCMFDPPMJOHL8 14.5 20.8 25.1 /FU&&3&OFSHZ&GGJDJFODZ3BUJP 3.31 3.22 12.1 RACK SPECIFICATIONS )FJHIU8JEUI%FQIUNN &RVJQNFOU)FJHIU &RVJQNFOU8JEUI&*"/PNJOBM 42U 483 (19 inch.) 1PXFSJOQVUGPSCBDLVQWFOUJMBUJPO 0.6 kW 'JSF&YUJOHVJTU optional 614GPSCBDLVQWFOUJMBUJPOBOEFRVJQNFOU optional 1PXFSTUJQT optional Knürr CoolTherm® 4–35 KW is featured in this Scenario: Knürr CoolTherm® 4–35 KW Scenario B1 page 12 &OFSHZFGGJDJFOUTFSWFSDBCJOFUUFDIOPMPHZXJUIPVUTUBOEJOH CFOFGJUTUPNJOJNJ[FFOFSHZDPTUTJOUIFEBUBDFOUFSBOE help SFEVDFDBSCPOEJPYJEFFNNJTJPOT CoolTherm®IBTTFUBCFODINBSLUIBUJTOPXXJEFMZVTFE BOESFDPHOJTFEJOUIFJOEVTUSZBOEBTBSFTVMUIBTNBUVSFE to become the standard. CoolTherm® therefore ranks as one of the best performing components of aperfected complete IT solution. 7BJSUPXBUFSIFBUFYDIBOHFS )FBUWPMVNFUPCFEJTTJQBUFE $PPM5IFSNL8OPNJOBMBTBOFYBNQMF 8BUFSTJEF1SFSVOUFNQFSBUVSF$QSFGFSSFE 1PTUSVOUFNQFSBUVSF$QSFGFSSFE .BYQSFTTVSFMPTTCBS 7PMVNFGMPXMT7FOUJMBUJPOWBMWF "JSTJEF6QUPNI"JSPVUMFU$UP$ effective cooling capacity Width Height 600mm NN 800mm 800mm 800mm 800mm NN NN NN 800mm 800mm 800mm 800mm 2000mm or 2200mm 800mm 800mm 800mm 800mm 800mm 800mm 800mm 800mm 800mm 800mm 25 kW 800mm 800mm 800mm 800mm NN 35 kW 800mm 800mm 800mm 800mm NN 4 kW 8 kW 12 kW L8 4QSFBEDIJMMFEXBUFS "JSUFNQFSBUVSFUPTFSWFS "JSUFNQFSBUVSFSFUVSOGSPNTFSWFS $POOFDUJPOIFBUFYDIBOHFS $POOFDUJPODPOEFOTBUFUSBZ 38 Depth 1200mm 1200mm NN NN Useable height 39 HU 43 HU )6 36 HU 40 HU )6 29 HU 33 HU 38 HU 31 HU 35 HU 40 HU 44 HU Useable depth Weight Water content 840mm LH 840mm YLH NN 290 kg LH NN 310 kg LH )6 42 HU NN 340 kg LH )6 42 HU NN 340 kg LH $$ $$ $$ ²GFNBMFUISFBU ²XBUFSIPTFDPOOFDUJPO 1SFTTVSFMPTTIFBUFYDIBOHFS NBYPQFSBUJPOQSFTTVSFIFBUFYDIBOHFS NBYBCTPMVUFIVNJEJUZPOTJUF 4UBOEBSEDPMPVST Electrical data ° 243 VAC )[ 190Watt °7"$ )[ 380Watt 200 – 264V )[ 550W 200 – 264V )[ 850W 200 – 264V )[ 1150W 200 – 264V )[ 1150W CBS CBS HLH 3"-CMBDLHSFZ 3"-MJHIUHSFZ Knürr CoolAdd® is featured in this Scenario: Knürr CoolAdd® Scenario B1 1-2 Racks Single Phase page 12 Knürr CoolAdd® represents the ideal retrofit solution for data centers and IT rooms. It safeguards against the risk of hotspots and helps to avoid overheating of the server racks. A special feature PGUIJTRVJDLBOEIJHIMZFGGFDUJWFTPMVUJPO JTUIBUUIFFYJTUJOHTFSWFSSBDLSFNBJOT XJUIJOUIFEBUBDFOUFS *OBEEJUJPOUIFFOUJSFXJSJOHNBZSFNBJO BTJUJTXJUIPVUUIFOFFEGPSBOZBMUFSBUJPOT Cooling capacity 8 kW Width Height Depth Weight 600mm NN 800mm 2000mm or 2200mm 160mm 41 kg VQUPLH 4QSFBEDIJMMFEXBUFS &YIBVTUUFNQFSBUVSFBGUFSIFBUFYDIBOHFS $POOFDUJPOIFBUFYDIBOHFS $PPMJOHXBUFSWPMVNFGMPX 1SFTTVSFMPTTIFBUFYDIBOHFS $ $ ²NBMFUISFBE NI NCBS Water content 1.6 l Fans Air-Volume flow 4 Fans NI .BYPQFSBUJOHQSFTTVSFIFBUFYDIBOHFS .BYBCTPMVUFIVNJEJUZPOTJUF 4UBOEBSEDPMPVST &MU$POOFDUJPOGBOTGBODPOUSPM 1SPUFDUJPODMBTT CBS HLH 3"-CMBDLHSFZ 7)[8 *1 39 Knürr RMS Compact II® 4ZTUFNBOEOFUXPSLNBOBHFNFOUSFRVJSFNFOUTNFBOUIFTZT UFNTµBNCJFOUDPOEJUJPOTNVTUCFNPOJUPSFE3FMJBCJMJUZBOE TZTUFNBWBJMBCJMJUZBSFJOEJTQFOTBCMF$PNQMJBODFXJUIUIFSF RVJSFEBNCJFOUQBSBNFUFSTJTFYUSFNFMZJNQPSUBOUGPSUIF fault-free operation of high-grade components. Inadmissible fluctuations in temperature or air humidity often DBVTFIBSEXBSFEFGFDUT$POTUBOUBVUPNBUJDNPOJUPSJOHPG UIFTFQBSBNFUFSTJTUIFSFGPSFBCBTJDSFRVJSFNFOUGPSFOTVSJOH properly functioning operability. 8JUIUIFSBDLNPOJUPSJOHTZTUFNTPGGFSFECZ,OSSUIJTJOGPS NBUJPODBOCFSFDPSEFEBOEGPSXBSEFEEJSFDUMZUPBIJHIFSMF vel management system. 5IJTSFDPSEJOHJTOPUIPXFWFSTVGGJDJFOUUPXBSEPGGEBNBHFT 'PSTIPSUSFTQPOTFUJNFTXIFOGBVMUTPDDVSJUJTIFMQGVMJGUIF monitoring system can perform actions automatically (e.g. activate additional fans). 8IFOEFGJOFEJODJEFOUTPDDVS,OSS3.4$PNQBDU**DBOJN NFEJBUFMZTFOEBNFTTBHFBTBO²4/.1USBQ³UPUIFNBOBHF ment system or directly as an e-mail to a technician or an SMS HBUFXBZ 3BQJEFSSPSGJOEJOHBOESFNPWBMJTWBMVBCMF5IFBCJMJUZUPDPO OFDUBEEJUJPOBMTFOTPSTUPNPOJUPSJOHTZTUFNTOPUPOMZBMMPXT racks to be monitored – so too can complete rooms or building sections. All important environmental parameters of a system DBODPOTFRVFOUMZCFSFDPSEFEBOEFWBMVBUFEJOBOFBTZBOE TUSBJHIUGPSXBSEXBZ RMS Compact II® Sensors Fan speed sensor - the RMS automatically recognizes this sensor as an analog sensor - offset and alarm parameters can be set in RMS - the sensor does not have to be recalibrated - OPBEEJUJPOBMQPXFSTVQQMZSFRVJSFE Temperature sensor ECO - insensitive to disturbances OPBEEJUJPOBMQPXFSTVQQMZ SFRVJSFE - the sensor does not have to be recalibrated Humidity sensor - insensitive to disturbances OPBEEJUJPOBMQPXFSTVQQMZ SFRVJSFE - the sensor does not have to be recalibrated Smoke detector - PQUJDBMTNPLFEFUFDUPSXJUI VdS approval - GPSFBSMZGJSFEFUFDUJPOXJUI smoke emission - QPXFSTVQQMZQSPWJEFEWJB RMS Compact II® Door contact sensor - NBHOFUCSJEHFTFOTPSXPSLT on every magnetic conductive material - can also be used for monitoring side panels and roof The advantages of Knürr’s modern rack monitoring system: 40 (VBSBOUFFTGBVMUGSFFPQFSBUJPO %FUFDUTEJTUVSCBODFTFBSMZ -PHTJODJEFOUT .BLFTTFSWJDFBTTJHONFOUTFBTJFS XJUIBVUPNBUJDNPOJUPSJOH "DUJWBUFTDPVOUFSNFBTVSFTJOUIFFWFOUPGBGBVMU $FOUSBMDPOUSPMPGDPOTVNBCMFT GJMUFSTQBQFSUPOFSNFUFSSFBEJOHT JOTQFDUJPOJOUFSWBMTFUD $POOFDUJPOPGVQUPTFOTPST in any arrangement Knürr ARC (Admin Rack Console) Knürr ARC (Admin Rack Console) - For installation in all 19” racks - 4QBDFTBWJOHXJUIPOMZ6JOTUBMMBUJPOIFJHIU 8JUIPVUPSXJUIJOUFHSBUFEBOEQPSU,7.4XJUDI *OUFHSBUFEDPVOUSZTQFDJGJDLFZCPBSEXJUIUPVDIQBE 5'5JOUIFQVTIFEJOTUBUVTQSPUFDUFEGSPNCFMPX *OUFSMPDLJOHGVMMFYUFOTJPOSBJMT - Hand support of GPBNSVCCFSGPSSFMBYFEXSJUJOH 5PVDIQBEXJUIJOUFHSBUFESJHIUNPVTFCVUUPOGVODUJPO 5PVDIQBEXJUITDSPMMGVODUJPO - Right and left mouse button *OUFHSBUFEXJEFSBOHFJOQVUQPXFSTVQQMZ7"$ XJUI*&$TPDLFU ,FZCPBSEXJUIOVNCFSCMPDL *OUFHSBUFE,7.TXJUDI - To control 8 or 16 computers direct and up to 256 computers total - Selection and control all Computers via an easy to use on-screen user interface. $POOFDUJPOCFUXFFOUIF,7.4XJUDIBOEUIFDPNQVUFSTWJB$BU cable and adapter module. 5IFBEBQUFSNPEVMFJTDPOOFDUFEUPUIFLFZCPBSEWJEFPNPVTF connector of the respective computer and provides failure safe access. - 5IF3*$$NPEVMFJTDPOOFDUFEUPUIFLFZCPBSENPOJUPSBOE mouse outputs of the respective computer and provides failureTBGFBDDFTTUPUIFDPNQVUFSXJUIUIFLFZCPBSENPVTFFNVMBUJPO - Multi-platform capable RICCs (in accessories range) enable the DPNCJOBUJPOPG1$T46/TBOEEFWJDFTXJUI64#JOUFSGBDF - The keyboard and mouse emulation is integrated in the RICC GPSGBVMUGSFFPQFSBUJPOXJUIJOUFSSVQUFEDBCMFDPOOFDUJPO Display Width Height Depth KVM Keyboard Language Colour ³-$% ³ 6 NN TJOHMFQPSU &OHMJTI646, (FSNBOZ'SBODF*UBMZ 4QBJO%FONBSL#FOFMVY4XJU[FSMBOE 4XFEFO643VT64$IJOFTF 3"-MJHIUHSFZ 3"-EBSLHSFZ ³-$% ³ 6 NN QPSU &OHMJTI646, (FSNBOZ'SBODF*UBMZ 4QBJO%FONBSL#FOFMVY4XJU[FSMBOE 4XFEFO643VT64$IJOFTF 3"-MJHIUHSFZ 3"-EBSLHSFZ Demands & Benefits Demands in the Data Center: ■ facility and distance independent management of remote sites have driven up the demand for remote access KVM solutions. ■ Key facts: *ODSFBTJOHUFNQFSBUVSBOEDPMMJOHBJSGMPX )JHIOPJTFFYQPTVSF $MPTFEIJHIEFOTJUZDPPMJOHTZTUFNT -JHIUTPVUEBUBDFOUFS $PMPDBUJPOGBDJMJUZ .PSFTFSWFSTPOMFTTBENJOJTUSBUPST ■ 4PNFBSFCVSTUJOHUPDBQBDJUZBTOFXEFWJDFTBSFBEEFETFDVSJUZ NFBTVSFNFOUTUBLFOBOEJOGSBTUSVDUVSFTTXFMMJOHUPLFFQQBDFXJUI UIFOFFEGPSNPSFDPNQMFYBQQMJDBUJPOTBOEUFDIOPMPHJFT ■ .BOZMBSHFDPNQBOJFTEPOPUSFBMJ[FUIFHSFBUQBJOTUIBUOFUXPSL BENJOJTUSBUPSTHPUISPVHIUPNBYJNJ[FSFBMFTUBUFJOBOFOUFSQSJTF class data center. ■ 4QBDFJTDPTUMZBOEOFUXPSLBENJOJTUSBUPSTDPOUJOVBMMZSFMZVQPO EFWJDFTUIBUIFMQUIFNEPNPSFXJUIMFTT ■ 0OFTVDIUPPMUPBJEJOUIJTFGGPSUJTUIF,7.LFZCPBSEWJEFPNPVTF TXJUDIUIBUFOBCMFT*5QSPTUPFBTJMZBOEFGGFDUJWFMZNBOBHFTFSWFSTBOE PUIFSOFUXPSLEFWJDFT°XJUIJOUIFEBUBDFOUFSPSGSPNSFNPUFMPDBUJPOT%BUBDFOUFSTBSFDPOUJOVJOHUPFYQBOE Customer Benefit ■ 8IFOVTJOH,7.SFNPUFMZUIFJOUFSGBDFBUGJSTUWJFXNBZTFFNTJNJMBSUPSFNPUFDPOUSPMTPGUXBSFTVDIBTQD"OZXIFSF8JOEPXT5FSNJOBM4FSWJDFT3FNPUF%FTLUPQ7/$FUD)PXFWFS CFDBVTF*1,7.JTOPUBTPGUXBSFCVUBIBSEXBSFTPMVUJPOJUµTNVDINPSFQPXFSGVM 04BOEIBSEXBSFJOEFQFOEFOU B,7.4XJUDIDBOCFVTFEUPNBOBHFTFSWFSTSVOOJOHNBOZQPQVMBS04JODMVEJOH*OUFM® Sun®1PXFS1$SVOOJOH8JOEPXT-JOVY®4PMBSJT5.FUD 4UBUFJOEFQFOEFOU"HFOUMFTT *1,7.TXJUDIFTEPFTOPUSFRVJSFUIFNBOBHFETFSWFS04UPCFVQBOESVOOJOHOPSEPFTJU SFRVJSFBOZTQFDJBMTPGUXBSFUPCFJOTUBMMFEPOUIFNBOBHFETFSWFS 0VUPG#BOE &WFOJGUIFNBOBHFETFSWFSµTPXOOFUXPSLDPOOFDUJPOJTVOBWBJMBCMFJUDBOTUJMMCFNBOBHFE through a KVM. #*04MFWFMBDDFTT &WFOJGUIFTFSWFSJTIVOHBUCPPUVQSFRVJSFTCPPUJOHUPTBGFNPEFPSSFRVJSFTTZTUFN #*04QBSBNFUFSTUPCFBMUFSFEUIF,7.TUJMMXPSLTGMBXMFTTMZUPFOBCMFUIFTFDPOGJHVSBUJPOT to be made. .PSFFGGJDJFODZJOUIFBENJOJTUSBUJPO &MJNJOBUJPOPGVOOFDFTTBSZUSBWFMUJNFT 3FEVDUJPOPG.553UJNFT QMBOOJOHSFMJBCJMJUZ *OWFTUNFOUQSPUFDUJPOBUTZTUFNPSQMBUGPSNDIBOHF *OUFHSBUJPOPG,7.1PXFSVOE&OWJSPNFOUBM.BOBHFNFOU 41 Liebert PowerSure™ PSI is featured in this Scenario: Liebert PowerSure™ PSI UPS Scenario A 1-2 Racks Single Phase page 10 -JFCFSU1PXFS4VSF14*614PGGFSTBOVOCFBUBCMFDPNCJOBUJPOPG GFBUVSFTBOEWBMVFJOPOMZ6PGSBDLTQBDF5IFVOJUJTSBDLUPXFS DPOGJHVSBCMFBOEIBTPQUJPOTGPSFYUFOEFECBUUFSZUJNFBOEDPNNVOJDBUJPOTIVUEPXO 5IF-JFCFSU1PXFS4VSF14*JTB6TJ[FMJOFJOUFSBDUJWF614BWBJMBCMFJOBOE7"SBUJOHTJO7BOE7 models. Features & Benefits Flexibility: ■ ■ ■ ■ &BTJFSUPDPOGJHVSFGPSFYUFOEFESVOtimes - the same 2U rack model can opFSBUFTUBOEBMPOFPSJOBOFYUFOEFE runtime application. $POGJHVSBCMF*OQVU7PMUBHF8JOEPX"MMPXTUIF614UPCFQSPQFSMZNBUDIFEUP UIFJODPNJOHVUJMJUZQPXFSBOEBEKVTUTJUT JOQVUXJOEPXBOEUSBOTGFSQPJOUTUPTVQQMZQSFDJTFMZSFHVMBUFEQPXFSUPJUTDPOOFDUFEMPBETXJUIJOUIFTFMFDUFESBOHF &BTJFTUTZTUFNNBOBHFNFOU±PQUJPOT BWBJMBCMFGPS8FC#BTFE4/.1PS34 NPOJUPSJOHBOEDPOUSPMTPGUXBSFGPSSFmote management. Delivered fully assembled and ready for JOTUBMMBUJPOUIFVOJUJODMVEFTGJYFESBDL SBJMTBOEUPXFSTUBOE Higher Availability: ■ ■ ■ ■ ■ &YUFOEFECBUUFSZSVOUJNF±CBUUFSJFT DBOCFBEEFEUPUIFFYJTUJOH614BOEBSF user-replaceable. 8JEFJOQVUWPMUBHFXJOEPXNFBOTJU USBOTGFSTUPCBUUFSZMFTTPGUFOTBWJOH CBUUFSZXFBSBOEUFBS "EWBODFEFBSMZXBSOJOHPG614TUBUVTWJB automatic and manual battery test feature. Lowest Total Cost Of Ownership: ■ Most price competitive product in its class. ■ 3FEVDFEJOTUBMMBUJPOUJNFBOEDPTUT± 614JTTIJQQFEXJUICBUUFSJFTDPOOFDUFE and charged. ■ 5XPZFBSOPIBTTMFSFQMBDFNFOUXBSranty. ■ High Energy Efficiency. Batteries fully charged at the factory and UFTUFEGPSTBGFUSBOTQPSU±$FSUJGJFEUP International Safe Transit Association standards. 3FNPUFFNFSHFODZQPXFSPGG Frequently Asked Questions Question Resolution I’ve been using other line-interactive UPSs for years, so why use Liebert’s PowerSure PSI systems now? 5IF-JFCFSU1PXFS4VSF14*PGGFSTTJHOJGJDBOUBEWBOUBHFTPWFSPUIFSMJOFJOUFSBDUJWFTZTUFNT"EWBOUBHFTJODMVEF ■ &YUFOEFECBUUFSZPQUJPOPOTBNFVOJUTPZPVEPOµUIBWFUPVQHSBEFUPBOPUIFS614 UPBEECBUUFSZDBCJOFUTBTZPVEPXJUIDPNQFUJUPS614T ■ %FMJWFSFEGVMMZBTTFNCMFE±CBUUFSJFTDPOOFDUFEBOEBDUJWBUFEBUUIFGBDUPSZ ■ 5XPZFBSOPIBTTMFSFQMBDFNFOUXBSSBOUZ I can get my normal brand of UPS shipped very quickly. How quickly can Liebert deliver? -JFCFSUNBJOUBJOTBXBSFIPVTFPGQSPEVDUTGPSRVJDLEJTUSJCVUJPO.BKPS%JTUSJCVUPST BMTPTUPDLNBOZTUBOEBSE-JFCFSU614QSPEVDUTGPSOFYUEBZTIJQNFOU 42 Competitive Advantage 5IF-JFCFSU1PXFS4VSF14*DBOPQFSBUFJOBOFUXPSLFOWJSPONFOUXJUIUIF-JFCFSUIntelliSlot8FC$BSEJOTUBMMFEGPS4/.1DPNNVOJDBUJPOT1MVTZPVDBOBEEFYUFOEFECBUUFSZCBDLVQXJUIPVUSFQMBDJOHUIFFYJTUJOHVOJUXJUIBMBSHFSNPEFM Feature Liebert PowerSure PSI Network Solution Package advantage Extended battery option on same unit Yes Two-year, no hassle replacement warranty Yes Four communications options Yes Rack rails/tower stand as standard equipment Yes Fully featured with comms cable, output cables, telecom cable Yes Liebert PSI and Accessories PowerSure PSI UPS VA/Watts UPS Battery External Battery Cabinet Batteries Rack Mounting Hardware Web/SNMP Card MicroPOD PS1000RT2-230 PS1000RT2-230 PS2200R2T-230E* PS3000RT2-230E* internal internal internal internal PS2-48VBATT PS2-48VBATT 147#"55 147#"55 *ODMVEFEXith all UPSs and Battery Cabinets Included XJUIBMM614T and Battery Cabinets IncludedXJUIBMM614T and Battery Cabinets IncludeEXJUIBMM614T and Battery Cabinets IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD MP2-210K MP2-210K MP2-220L MP2-220L 43 Liebert PowerSure™ PSI UPS Technical Data: Model PS1000RT2-230 PS1440RT2-230 PS2200RT2-230E PS3000RT2-230E Power Rating 7"8 Dimensions 6OJU8Y%Y)NN 6 YY 6 YY 6 YY 6 YY 4IJQQJOH8Y%Y)NN YY YY YY YY Weight 6OJULH 4IJQQJOHLH Input Parameters Surge Protection 660J 7PMUBHF3BOHFXP#BUUFSZ0QFSBUJPO 7"$DPOGJHVSBCMF%JQTXJUDITFMFDUBCMF7 45-65Hz (±0.1) 'SFRVFODZ3BOHF *OQVU1PXFS$POOFDUJPO 1 IEC-320-C14 1 IEC-320-C14 8 IEC-320-C13 8 IEC-320-C13 1 IEC-320-C20 1 IEC-320-C20 Output Parameters Output Receptacles *&$$*&$$ *&$$*&$$ 2 m detached IEC-320-C14 0VUQVU1PXFS$BCMFT Tension (mode normal) 220-230-240VAC ±10% Voltage (Battery Mode) 230VAC ±8% Waveform (Batterymode) 4JOFXBWF 50 or 60Hz (auto-sensing) 'SFRVFODZ 0WFSMPBEXBSOJOH /PSNBMBOE#BUUFSZ.PEF >200% - shortcircuit; after 15 cycles (normal mode) 0WFSMPBE4IVUEPXO Battery Parameters Type - Approved manufacturers 2VBOUJUZY7PMUBHFY3BUJOH 7BMWFSFHVMBUFEOPOTQJMMBCMFMFBEBDJE###BUUFSJFT$4#1BOBTPOJD&OFSTZT Y7Y"I Y7Y"I Y7Y"I Transfer time Backup Time 'VMMMPBENJOVUFT )BMGMPBENJOVUFT Y7Y"I 4-6ms typical "U$SFTJTUJWFMPBEJOHXJUIGVMMZDIBSHFECBUUFSJFT Recharge time )PVSTUPDBQBDJUZBGUFSGVMMEJTDIBSHFJOUPBSFTJTUJWFMPBE Battery test Every 14 days )PU4XBQ#BUUFSJFT Yes Deep discharge protection Yes #MBDLTUBSUXPNBJOT Yes Environmental < 40dB normalmode operation /PJTF Operating temperature Operating Altitude $UP$ 6QUPNXJUIPVUEFSBUJOH 6QUPNXJUIPVUEFSBUJOH 6QUPNXJUIPVUEFSBUJOH 6QUPNXJUIPVUEFSBUJOH 64#4FSJBM34$POUBDU$MPTVSF8FCBOE4/.1PQUJPOBMDBSE Comunications USB Compatibility 8JOEPXT8JOEPXT91"QQMF.BD04 4PGUXBSF$PNQBUJCJMJUZ .VMUJ-JOL9TVQQPSUT.48JOEPXT/591.&"*9-JOVY4VO4PMBSJT)169/PWFMM/FUXBSF :FBST4UBOEBSE:FBSXBSSBOUZFYUFOTJPOBWBJMBCMF Warranty Standards & Requirements Safety &/$&MPXWPMUBHFEJSFDUJWF567$FSUJGJDBUF &.*&.$ &/$MBTT#$&&.$EJSFDUJWF Design -JOF*OUFSBDUJWF*&$7*&/&/&/ Battery Cabinets &YUFOTJCMF#BUUFSJFT PS2-48VBATT PS2-48VBATT 147#"55 147#"55 6OJU8Y%Y)NN YY YY YY YY 4IJQQJOH8Y%Y)NN YY YY YY YY Weight 6OJULH 4IJQQJOHLH 2VBOUJUZY7PMUBHFY3BUJOH CZY7Y"I CZY7Y"I CZY7Y"I CZY7Y"I Approved Manufacturers $4###&OFSTZT Battery cabinet package #BUUFSZ$BCMF5PXFSTUBOETVQQPSUCBTF3BDLNPVOUIBOEMFTBOEGJYFESBJMLJUT Extended Backup time $BCJOFUGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE 44 Liebert GXT™ is featured in these Scenarios: Liebert GXT™ UPS Scenario B 1-2 Racks Single Phase page 12 Scenario C 3-6 Racks Three Phase page 14 Liebert GXT UPS leads the industry in combining the best UPUBMDPTUPGPXOFSTIJQXJUITNBMMTJ[FIJHIDBQBDJUZBOEGVODUJPO SJDIGFBUVSFT5IJTUSVFPOMJOF614PGGFSTJOUFSOBMCBUUFSJFTVOMJNJUFEFYUFOEFEFYUFSOBMCBUUFSJFTBOEJOUFSOBMCZQBTTDBQBCJMJUZ SFTVMUJOHJODPOUJOVPVTVQUJNFGPSUIFDPOOFDUFEFRVJQNFOU %FTJHOFEGPSSBDLNPVOUPSUPXFSNPEFTUIF-JFCFSU(95JTBWBJMBCMFJOBOE 7"SBUJOHTJOCPUI7BOE7NPEFMT Features & Benefits Flexibility: ■ ■ ■ ■ Unit can be installed in either rack or UPXFSBQQMJDBUJPOT The Liebert GXT automatically detects BOENBUDIFTMJOFJOQVUGSFRVFODJFTPGFJther 60 or 50 Hz. $PNQBUJCMFXJUICBDLVQHFOFSBUPS± IBOEMFTGSFRVFODZWBSJBUJPOTBOEPUIFS QPXFSGMVDUVBUJPOTUIBUPDDVSEVSJOH generator operation. $POGJHVSBUJPOQSPHSBNBMMPXTTFMFDUJPO PG614GFBUVSFTJODMVEJOHPVUQVUWPMUBHF BVUPSFTUBSUFOBCMFEJTBCMFBOEPUIFS features. Higher Availability: ■ ■ Protection and conditioning against all GPSNTPGQPXFSBOPNBMJFT Internal automatic and manual bypass BTTVSFDPOUJOVJUZPGQPXFSUPDSJUJDBM loads during system maintenance or in case of internal fault. ■ 8JEFJOQVUWPMUBHFXJOEPXBMMPXTUIF 614UPTVQQPSUUIFDSJUJDBMMPBEXJUIPVU IBWJOHUPUSBOTGFSUPCBUUFSZFYUFOEJOH TZTUFNBWBJMBCJMJUZGPSXIFOCBUUFSZ backup is truly needed. ■ 6TFSSFQMBDFBCMFIPUTXBQQBCMFJOUFSOBM batteries. ■ "EWBODFEFBSMZXBSOJOHPG614TUBUVTWJB automatic and manual battery test feature. Lowest Total Cost Of Ownership: ■ $PSSFDUTGPSGSFRVFODZWBSJBUJPOTXJUIPVU TXJUDIJOHUPCBUUFSZSFTVMUJOHJOMPOHFS battery life. ■ 5XPZFBSOPIBTTMFSFQMBDFNFOUXBSranty. Frequently Asked Questions Question Resolution Why should I consider using online, double-conversion UPS technology? 8IJMFMJOFJOUFSBDUJWF614UFDIOPMPHZJTBQQSPQSJBUFGPSNBOZTJUVBUJPOTUIFSFNBZCF UJNFTXIFOZPVOFFEHSFBUFSQPXFSDBQBDJUZPSIJHIFSMFWFMTPGBWBJMBCJMJUZPGGFSFECZ online double-conversion technology. 8JUI[FSPUSBOTGFSUJNFXIFOTXJUDIJOHUPCBUUFSZPOMJOFUFDIOPMPHZµTDMFBOQPXFS UISPVHIQPXFSDPOEJUJPOJOH DBVTFTMFTTTUSFTTPOQPXFSTVQQMJFTDSFBUJOHUIF IJHIFTUMFWFMPGFRVJQNFOUQSPUFDUJPO 0WFSUJNFUIFPOMJOFEPVCMFDPOWFSTJPO-JFCFSU(95BMTPPGGFSTBOBUUSBDUJWFUPUBMDPTU PGPXOFSTIJQ#FDBVTFBOPOMJOFTZTUFNDPSSFDUTGPSGSFRVFODZWBSJBUJPOTXJUIPVU TXJUDIJOHUPCBUUFSZJUDBOHSFBUMZFYUFOEUIFMJGFUJNFPGUIF614CBUUFSZ Is the Liebert GXT compatible with a backup generator? (FOFSBUPSTEPOPUQSPWJEFDPNQVUFSHSBEF"$QPXFSSFRVJSFECZUPEBZµTTFOTJUJWF FMFDUSPOJDT"USVFPOMJOF614TVDIBTUIF-JFCFSU(95XJMMXPSLXJUIBHFOFSBUPSBOE QSPWJEFUJHIUWPMUBHFBOEGSFRVFODZSFHVMBUJPO5IF614XJMMCSJEHFUIFHBQCFUXFFO MPTTPG"$QPXFSBOEUIFUJNFJUUBLFTZPVSHFOFSBUPSUPDPNFVQUPTQFFEBOEZPVS MPBETUPCFTXJUDIFEUPHFOFSBUPSQPXFS±DBOZPVSCVTJOFTTDSJUJDBMBQQMJDBUJPOTCF XJUIPVUQPXFSGPSFWFOBGFXNJOVUFT How fast can I get a Liebert GXT shipped to my customer? -JFCFSUNBJOUBJOTBXBSFIPVTFPGQSPEVDUTGPSRVJDLEJTUSJCVUJPO.BKPSEJTUSJCVUPST BMTPTUPDLNBOZTUBOEBSE-JFCFSU614QSPEVDUTGPSOFYUEBZTIJQNFOU 45 Competitive Advantage 5IF-JFCFSU(95PGGFSTBOVNCFSPGBEWBOUBHFTPWFSUIFDPNQFUJUJPOXIJDIZPVDBOVTFUPHFOFSBUFOFXIJHINBSHJOTBMFT Feature Liebert GXT Capacity range down to 700VA. Yes Widest input frequency window (40-70Hz). Yes Delivered fully assembled — batteries connected and activated at the factory. Yes Standard rack ears and tower pedestal. Yes Two-year, no hassle replacement warranty Yes Liebert GXT Product Ancillary Guide Liebert GTX UPS GXT2-700RT230 GXT2-1000RT230 GXT2-1500RT230 GXT2-2000R230 internal internal internal internal External Battery Cabinet GXT2-48VBATT GXT2-48VBATT GXT2-48VBATT GXT2-48VBATT 4-Post Rack Mounting Kit RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 Web/SNMP Card IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD MicroPOD MP2-210K MP2-210K MP2-210K MP2-210K GXT2-3KRT230E GXT2-4500RT230 GXT2-6000RT230 GXT2-10000R230* internal internal internal GXT2-240RVBATT√ External Battery Cabinet (957#"55 GXT2-240VBATT GXT2-240VBATT GXT2-240RVBATT 4-Post Rack Mounting Kit RMKIT18-32 RMKIT18-32 RMKIT18-32 RMKIT18-32 Web/SNMP Card IS-WEBCARD IS-WEBCARD IS-WEBCARD IS-WEBCARD MicroPOD MP2-220L PD-CEHDWRBYP PD-CEHDWRBYP - VA/Watts UPS Battery Kit Liebert GTX UPS UPS VA/Watts UPS Battery Kit (59JTBMTPBWBJMBCMFJOUPXFSWFSTJPO 46 £3FRVJSFE614$PNQPOFOUT Liebert GXT™ UPS Technical Data - GTX2 GTX2 700RT230 Model GTX2 1000RT230 GTX2 1500RT230 GTX2 2000RT230 GTX2 3KRT230E GTX2 4500RT230 GTX2 6000RT230 Power Rating VA 1000 1500 2000 3000 4500 6000 W 490 1050 1400 2100 3150 4200 Dimensions & Weight 6OJU8Y%Y)NN 6 YY 6 YY 6 YY YY YY YY 4IJQQJOH8Y%Y)NN Weight 6OJULH 4IJQQJOHLH Input Parameters 7PMUBHFBOE'SFRVFODZ 7"$VTFSTFMFDUBCMF)[ 7PMUBHF3BOHFXP#BUUFSZ 7"$WBSJBCMFEFQFOEJOHPOMPBE 'SFRVFODZ3BOHF 7"$ )[BVUPTFOTJOH IEC-320-C14 IEC-320-C20 )BSEXJSFE (4) IEC-320-C13 *&$$ (1) IEC-320-C19 )BSEXJSFE (2) IEC-320-C19 *OQVU1PXFS$POOFDUJPO Output Parameters Output Receptacles 8BWFGPSN'SFRVFODZ 4JOFXBWFPS)[/PNJOBM)[EFGBVMU Overload Warning >200% for 96 milliseconds; 131-199% for 2 seconds; 112-129% for 10 seconds XJUIUSBOTGFSUPCZQBTT GPS$ZDMFTGPSTFDPOETXJUIUSBOTGFSUPCZQBTT Battery Parameters Type Approved manufacturers 73-"OPOTQJMMBCMFGMBNFSFUBSEBOU Panasonic UP-VW 1245P1 $IJOB4UPSBHF#BUUFSZ$4#'3' 2VBOUJUZY7PMUBHFY3BUJOH Y7Y"I :VBTB3&8'3 Y7Y"I Y7Y"I Y7Y"I Backup Time Half load (minutes) 44 25 20 14 16 24 Full load (minutes) 11 6 6 10 Recharge time 5 Hours to 95% #BUUFSJFTPUIFSGFBUVSFT )PU4XBQ#BUUFSJFT%FFQ%JTDIBSHF1SPUFDUJPO#MBDL4UBSUXPNBJOT Battery Test "VUPNBUJD6TFSDPOGJHVSBCMFEBZT Environmental < 50dB /PJTF < 55dB Operating temperature $UP$ Operating Altitude 0 - 3000 m 4FSJBM34TUBOEBSE64#$BSE3FMBZDBSEBOE4/.18FC$BSEPQUJPOBM Comunications Common Package Additional Components Warranty 6TFSNBOVBM.VMUJMJOLTPGUXBSF$%.VMUJMJOLTFSJBMDBCMFN3BDLNPVOUIBOEMFT5PXFSTVQQPSUCBTF$POGJHVSBUJPOQSPHSBNEJTL 4DIVDLP$&& *OQVUPVUQVUEJTUSJCVUJPO1%$&)%83 UP*&$$ JOQVUPVUQVUEJTUSJCVUJPOXJUINBJOUF "*&$$0VUQVU$BCMFT and (1) BS136 to nance bypass PD CEHDWRBYP (optio*&$$" nal) JOQVUQPXFSDPSE 2 Years Standards & Requirements Safety &/$&DPNQMJBODFNBSLGPSCPUI-PX7PMUBHFBOE&.$%JSFDUJWFT %FTJHO&.*&.$5SBOTportation &/5f7(4$&&.$%JSFDUJWF 7'*44BDDPSEJOHUP*&$&/$MBTT"&/*45"1SPDFEVSF" Extended Battery Cabinets Models GTX2-48V Battery (597#BUUFSZ GTX2-240V Battery 6OJU8Y%Y)NN 6 YY 6 YY 6 YY YY YY YY Unit (kg) 28.3 42.5 65 Shipping (kg) 32.3 46.5 YY7Y"I YY7Y"I Y7Y"I $IJOB4UPSBHF#BUUFSZ$4#'3' 1BOBTPOJD6178 1245P1 :VBTB3&8'3 4IJQQJOH8Y%Y)NN Weight 2VBOUJUZY7PMUBHFY3BUJOH Approved Manufacturers Battery cabinet package #BUUFSZ$BCMF5PXFSTUBOETVQQPSUCBTF3BDLNPVOUIBOEMFTBOEGJYFESBJMLJUT Extended Backup time $BCJOFUGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE $BCJOFUTGVMMIBMGMPBE Specification: UPS UNIT 1PXFS7"8 %JNFOTJPOT8Y%Y)NN Weight - Unit (kg) Degree of protection Color Input Voltage *OQVU0VUQVU'SFRVFODZ Input Voltage Tolerance 8JUIPVUQVUEFSBUJOH *OQVU'SFRVFODZ5PMFSBODF *OQVU1PXFS'BDUPS5)%J Input & Output Connections Output Wave Form Battery Module 0WFSMPBEXBSOJOH Short circuit current for 5 cycles Efficiency "DPVTUJD/PJTF Operating temp and altitude Relative Humidity Communications Battery Cabinet Models Dimensions Weight - Unit (kg) Backup timeminutes $BCJOFUT'VMMMPBE)BMGMPBE Batteries Battery Test Warranty and Standards Warranty 4UBOEBSET3FRVJSFNFOUT Safety Electromagnetic compatibility Design Transport 48 GXT2-10000R230 Y614CPEZIBOEMFTBOEQMVHTFYDMVEFE Y6 LHFMFDUSPOJDTEPFTOPUJODMVEFCBUUFSJFT IP20 IBM Black - Ral 9005 7-/TJOHMFQIBTF-/( )[BVUPTFMFDUJOQVUDPOGJHVSBCMFPVUQVU 7777 XJUIJOOPNJOBM )BSEXJSFE 4JOFXBWF NJOVUFTFDPOETTFDPOET 160A peak (typical) 92% <55dBA $XJUICBUUFSJFT $XJUIPVUCBUUFSJFT 0-90% non condensing %#*OUFMMJTMPU3FMBZ$PNNT GXT2-240RVBATT 8Y%Y)NN Y614CPEZIBOEMFTBOEQMVHTFYDMVEFE Y6 :VBTB/18PS3&8Y78"I BVUPNBUJDDPOGJHVSBCMFUPEBZT 2 years CE Mark *&$&/$&-PX7PMUBHFEJSFDUJWF&&$ *&$&/$MBTT"$&&.$EJSFDUJWF&&$ IEC 62040-3 VFI-SS-111 ISTA Level 1A Liebert NX™ is featured in this Scenario: Liebert NX™ UPS (10-30 kVA) Scenario D 7-10 Racks Three Phase page 16 5IF-JFCFSU/9JTBUSVFPOMJOFEPVCMFDPOWFSTJPONJETJ[FE614 TZTUFNUIBUEFMJWFSTDPNQMFUFDFOUSBMJ[FEQPXFSQSPUFDUJPOGPS mission-critical systems. Designed to meet the high availability QPXFSOFFETPGBXJEFWBSJFUZPG*5BQQMJDBUJPOTUIF-JFCFSU/9is PGGFSFEJOUISFFTJOHMFQIBTF/9G BOEGPVSUISFFQIBTF/9F popular ratings combining DPNQBDUTJ[Fcapacities up to 6 parallel 30kVA unitsBEWBODFEPQFSBUJOHGFBUVSFTBOEMPXDPTUPGPXOership. Features & Benefits Flexibility: ■ ■ ■ ■ ■ ■ Communications available through a 3FMBZ$POUBDU$BSE-JFCFSU*OUFMMJ4MPU™ Web Card and Liebert MultiLink™ shutEPXOTPGUXBSF 6MUSBRVJFUQFSGPSNBODFXJUIOPJTFMFWFM from 51dB (10kVA) to 56dB (30kVA) alMPXTHSFBUFSMBUJUVEFJOXIFSFUPQMBDF the unit. Large and user-friendly LCD display provides operating information in 12 languages. Higher Availability: ■ ■ ■ Easy servicing due to front accessibility of DSJUJDBMDPNQPOFOUTTFMGEJBHOPTUJDTBOE various monitoring options. Capable to give 320% of nominal current for 200ms to clearbranch circuit breakers. Advanced inverter control technology proWJEFTUIFIJHIFTUPVUQVUQPXFSRVBMJUZ ■ 3FEVOEBOUQPXFSTVQQMZCPBSETSFEVOdant cooling fans and highly efficient cooling of critical components. ■ .JOJNJ[FEUSBOTGFSUPCBUUFSZSFEVDJOHUIF OVNCFSPGDIBSHJOHBOEEJTDIBSHJOHDZDMFT EVFUPUIFXJEFSJOQVUWPMUBHFXJOEPXPG UPBOEBGSFRVFODZUPMFSBODFPG )[UP)[ 6QUP-JFCFSU/9DBOCFQBSBMMFMFEGPS DBQBDJUZPSSFEVOEBODZXJUIPVUVTJOHB centralized controller or centralized TUBUJDTXJUDI For safe and convenient servicing of the 614UIF-JFCFSU/9JODMVEFTBCVJMUJO NBJOUFOBODFCZQBTT"OPQUJPOBMXSBQ around maintenance bypass cabinet is also available. True online double conversion technology DPSSFDUTBMMUZQFTPGQPXFSGMVDUVBUJPOT ■ Lowest Total Cost Of Ownership: ■ Temperature-compensated battery DIBSHJOHFYUFOETCBUUFSZMJGF ■ )JHIFTUQPTTJCMFJOQVUQPXFSGBDUPSUP safe on electricity bill and generator sizing. ■ "EKVTUBCMFQPXFSXBMLJOGSPNTFDPOET UPTFDPOETBMPOHXJUISFEVDFEJOQVU DVSSFOUEJTUPSUJPOBOEQPXFSGBDUPSDPSSFDUJPOBMTPFOBCMFTZPVUPTBWFNPOFZ by reducing backup generator sizing reRVJSFNFOUT ■ 5IFVOJUµTDPNQBDUGPPUQSJOUSFRVJSFT MFTTGMPPSTQBDFMFBWJOHZPVXJUINPSF SPPNGPSPUIFSFRVJQNFOU )JHIFTUMFWFMPGBWBJMBCJMJUZXJUIWJSUVBMMZOP EPXOUJNFFWFS5JFS “■ High overload rating handles 110% for 1 hour 125% for 10 minutes 150% for one minute. ■ An intelligent battery management algorithm monitors the battery to detect any premature battery failure. 49 Frequently Asked Questions Question Resolution Besides providing backup when the electricity goes out, does the Liebert NX take care of all power problems? Yes. It utilizes true on-line double conversion technology that corrects all types of QPXFSGMVDUVBUJPOT Is it more expensive to operate than sev- 5IF-JFCFSU/9BDUVBMMZPGGFSTBMPXFSUPUBMDPTUPGPXOFSTIJQUIBONBOZTNBMMFS614 eral UPS systems? units. Longer battery life and scheduled maintenance ensure proper system operation BOEQSFWFOUUIFDPTUTPGEPXOUJNF What if the UPS fails — will all my systems go down? 5IF-JFCFSU/9GFBUVSFTBCVJMUJOBVUPNBUJDCZQBTTUIBUBMMPXTUIFVOJUUPQSPWJEF QPXFSFWFOJGBDPNQPOFOUGBJMT What if the batteries suddenly fail and the equipment is without protection? 5IF-JFCFSU/9VUJMJ[FTBOJOUFMMJHFOUCBUUFSZNBOBHFNFOUTZTUFNUIBUNPOJUPSTUIF battery to detect any premature battery failure. How reliable is the Liebert NX? 5IF-JFCFSU/9GFBUVSFTCVJMUJOSFMJBCJMJUZXJUIBSFEVOEBOUBVYJMJBSZQPXFSTVQQMZ board and redundant cooling fans. Competitive Advantage 5IF-JFCFSU/9PGGFSTBOVNCFSPGBEWBOUBHFTPWFSUIFDPNQFUJUJPONBLJOHUIF-JFCFSU/9614UIFJEFBM61 for mission critical applications. Feature Liebert NX 10-30 kVA The Liebert Advantage Battery Use Permissible Input Voltage Range (VAC) froN7UP7 -FTTCBUUFSZVTFNFBOTGFXFSCBUUFSZSFQMBDFNFOUTBOESFTVMUTJOBMPXFSUPUBMDPTUPGPXOFSship. Audible Noise From 51 dbA (10kVA) to 56 dbA (30 kVA) :PVDBOVUJMJ[FBO/9JOBOPffice environment. Handling Of Overload Conditions 125% for 10 minutes 150% for 1 minute 5IFVTFSDBODPOOFDUBMPBEUPUIF/9XJUIPVUXPSrying about driving the UPS into bypass or shutEPXO Easy to install Compact dFTJHOJOUFSOBMCBUUFSZ *ONBOZDBTFTZPVSDVTUPNFSµTGBDJMJUZQFPQMFDBO install it tPLFFQUIFJSDPTUTEPXO 50 Liebert NX™ UPS (10-30 kVA) Technical Characteristics Models Rated Power @ 0.8 PF [kVA] NXf 10 NXe 15 20 10 15 20 30 Rectifier Input Rectifier Type IGBT-based Vector Controlled PFC (PF Corrected) Input Voltage [Vac] QI/"DDFQUFEGSPNUPXJUIPVUCBUUVTF *OQVU'SFRVFODZ<)[> PS"DDFQUFESBOHFGSPNUP Input Current THD XJUIPVUBOZ'JMUFS *OQVU1PXFS'BDUPS XJUIPVUBOZ'JMUFS 5 to 30 (selectable) 1PXFS8BML*O<T> Bypass Input Input Voltage [Vac] QI/ QI/ Battery Battery Type 73-"7BMWF3FHVMBUFE-FBE"DJE PS8FU'MPPEFEPS/J$E Selectable from 1.60 to 1.90 (for VRLA) &OE$FMM7PMUBHF<7ED$FMM> DC Ripple Current (float) <5% (of C10 AH capacity) RMS value DC Ripple Voltage (float & const V Ch) <1% (RMS value) Temp. Comp. Charge 4UBOEBSEXIFSFJOUFSOBMCBUUFSJFT BOE0QUJPOBMGPSBMMPUIFSCBUUFSZDPOGJHVSBUJPOT Output Inverter Type 0VUQVU1PXFS<L8> *(#5CBTFE7FDUPS3FQFUJUJWF1*$POUSPMMFE 8 Output Voltage [Vac] 12 16 8 12 QI/ 16 24 QI/ 0VUQVU'SFRVFODZ<)[> PSBEKVTUBCMF Output Voltage THD NBY MJOFBSMPBE .BY-PBE$SFTU'BDUPS DPNQMJBOUXJUI*&$ Transient Volt. Resp. [ms] UPSFDPWFSPG/PNJOBM7PMUBHFGPSUPPSUPTUFQMPBE Min. Leading PF Load %PXOUP Voltage Displacement [°el] /PUBQQMJDBCMF Overload FMXJUIVOCBMBODFEMPBE GPSNJOVUFTGPSNJOVUFTGPSNJOVUF Efficiency AC-AC up to 96.6% VQUP Physical Parameters Width [mm] 600 Depth [mm] Height [mm] 1400 8FJHIUBQQSPY XJUIPVUCBUU<LH> UPS Enclosure IP 180 200 200 180 204 204 210 *1FWFOXJUIPQFOGSPOUEPPS Standards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nvironmental Storage Temp. [°C] Operating Temp. [°C] Relative Humidity .BYJNVN"MUJUVEF<N> above Mean Sea Level UP614 UP#BUUFSZ UP614 #BUUFSZ 0 to 95% (non-condensing) 1000 (as per IEC 62040-3) 51 Liebert NX™ UPS (40-200 kVA) Liebert NX™ is featured in this Scenario: Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 5IF-JFCFSU/9BJTBUSVFPOMJOFEPVCMFDPOWFSTJPO614TZTUFN UIBUEFMJWFSTDPNQMFUFDFOUSBMJ[FEQPXFSQSPUFDUJPOGPSNJTTJPO DSJUJDBMTZTUFNT%FTJHOFEUPUPNFFUUIFIJHIBWBJMBCJMJUZQPXFS OFFETPGTNBMMBOENFEJVNEBUBDFOUFSTUIF-JFCFSU/9JTPGGFSFEJOQIBTFQPQVMBSSBUJOHTDPNCJOJOHDPNQBDUTJ[FDBQBDJUJFTVQUPQBSBMMFML7"VOJUTBEWBODFEPQFSBUJOH GFBUVSFTBOEMPXDPTUTPGPXOFSTIJQEFMJWFSJOH Features & Benefits Flexibility: ■ ■ ■ ■ ■ ■ Communications available through a 3FMBZ$POUBDU$BSE-JFCFSU*OUFMMJTMPU Web Card and Liebert Multilink shutEPXOTPGUXBSF 6MUSBRVJFUQFSGPSNBODFXJUIOPJTFMFWFM CFUXFFOE#BOEE#BMMPXTHSFBUFS MBUJUVEFJOXIFSFUPQMBDFUIFVOJU Large and user friendly LCD display provides operating information in 12 languages 6QUP-JFCFSU/9DBOCFQBSBMMFMFEGPS DBQBDJUZPSSFEVOEBODZXJUIPVUVTJOH a centralized controller or centralized TUBUJDTXJUDI For safe and convenient servicing of the 614UIF-JFCFSU/9JODMVEFTBCVJMUJO NBJOUFOBODFCZQBTT"OPQUJPOBMXSBQ around maintenance bypass cabinet is also available Easy servicing due to front accessibility PGDSJUJDBMDPNQPOFOUTTFMGEJBHOPTUJD and various monitoring options 52 Higher Availability: ■ ■ ■ ■ True on line double conversion technolPHZDPSSFDUTBMMUZQFTPGQPXFSGMVDUVBtions Capable to give 320% of nominal current for 200ms to clearbranch circuit breakers ■ 3FEVOEBOUQPXFSTVQQMZCPBSETSFEVOdant cooling fans and highly efficient cooling of critical components .JOJNJ[FEUSBOTGFSUPCBUUFSZSFEVDJOH the numbers of charging and dischargJOHDZDMFTEVFUPUIFXJEFSJOQVUWPMUBHFXJOEPXPGBOEBGSFRVFODZ UPMFSBODFPG)[UP)[ ■ $PNQBUJCJMJUZXJUIEVBM#VT4ZODISPOJ[Btion system enables you to transfer the MPBEUPBOBMUFSOBUFQPXFSTPVSDFGPS maintenance activities High overload rating handles 110% for 1 hour 125% fot 10 minutes 150% for one minute Temperature-compensated battery DIBSHJOHFYUFOECBUUFSZMJGF ■ )JHIFTUQPTTJCMFJOQVUQPXFSGBDUPSUP safe on electricity bill and generator sizing ■ "EKVTUBCMFQPXFSXBMLJOGSPNUP TFDPOETBMPOHXJUISFEVDFEJOQVU DVSSFOUEJTUPSUJPOBOEQPXFSGBDUPSDPSSFDUJPOBMTPFOBCMFTZPVUPTBWFNPOFZ by reducing backup generator sizing SFRVJSFNFOUT ■ 5IFVOJUµTDPNQBDUGPPUQSJOUSFRVJSFT MFTTGMPPSTQBDFMFBWJOHZPVXJUINPSF SPPNGPSPUIFSFRVJQNFOU Advanced inverter control technology QSPWJEFTUIFIJHIFTUPVUQVUQPXFSRVBMity ■ ■ Lowest Total Cost Of Ownership: Competitive Advantage Feature Liebert NX 40-200 kVA The Liebert Advantage Usable Input Voltage Range (VAC) 7UP7-PBE 208V to 47-PBE A broader input voltage range results in less batUFSZVTFGFXFSCBUUFSZSFQMBDFNFOUTBOEBMPXFS total cosUPGPXOFSTIJQ Audible Noise 55-66 dBA -PXFSOPJTFMFWFMQSPWJEFTNPSFGMFYJCJMJUZXIFOMPcating UPS near an office environment. Handling Of Overload Conditions 125% for 10 minutes 150% for 1 minute 5IFVTFSDBODPOOFDUBMPBEUPUIF/9XJUIPVUXPSrying about driving the UPS into bypass or shutEPXO Fast Battery Recharge Intelligent battery management Fast recharge times enhance system availability. 53 Liebert NX™ UPS (40-200 kVA) Technical Characteristics Models NXa Rated Power @ 0.8 PF [kVA] 40 60 Rectifier Input Rectifier Type 80 100 120 140 160 200 IGBT-based Vector Controlled PFC (PF Corrected) Input Voltage [Vac] QI/"DDFQUFEGSPNUPXJUIPVUCBUUVTF *OQVU'SFRVFODZ<)[> PS"DDFQUFESBOHFGSPNUP Input Current THD XJUIPVUBOZ'JMUFS *OQVU1PXFS'BDUPS XJUIPVUBOZ'JMUFS 1PXFS8BML*O<T> Bypass Input Input Voltage [Vac] Battery Battery Type 5 to 30 (selectable) QI/ 73-"7BMWF3FHVMBUFE-FBE"DJE PS8FU'MPPEFEPS/J$E Selectable from 1.60 to 1.90 (for VRLA) &OE$FMM7PMUBHF<7ED$FMM> DC Ripple Current (float) <5% (of C10 AH capacity) RMS value DC Ripple Voltage (float & const V Ch) <1% (RMS value) Temp. Comp. Charge Output Inverter Type 4UBOEBSEXIFSFJOUFSOBMCBUUFSJFTL7" BOE0QUJPOBMGPSBMMPUIFSCBUUFSZDPOGJHVSBUJPOT *(#5CBTFE7FDUPS3FQFUJUJWF1*$POUSPMMFE 32 0VUQVU1PXFS<L8> 48 64 80 96 112 Output Voltage [Vac] QI/ 0VUQVU'SFRVFODZ<)[> PSBEKVTUBCMF Output Voltage THD 128 160 NBY MJOFBSMPBE .BY-PBE$SFTU'BDUPS DPNQMJBOUXJUI*&$ Transient Volt. Resp. [ms] UPSFDPWFSPG/PNJOBM7PMUBHFGPSUPPSUPTUFQMPBE Min. Leading PF Load %PXOUP Voltage Displacement [°el] FMXJUIVOCBMBODFEMPBE Overload Efficiency AC-AC Physical Parameters Width [mm] 600 1000 Depth [mm] 825 825 Height [mm] 1600 1800 825 1800 GPSNJOVUFTGPSNJOVUFTGPSNJOVUF VQUP 8FJHIUBQQSPY XJUIPVUCBUU 341 <LH> UPS Enclosure IP Standards Operating Temp. [°C] Relative Humidity .BYJNVN"MUJUVEF<N> above Mean Sea Level 54 445 900 900 1060 *1FWFOXJUIPQFOGSPOUEPPS Environmental Storage Temp. [°C] 401 4BGFUZ*&$&/"4JODPSQPSBUJOHSFRVJSFNFOUTPG*&$&/"4 &.$*&$&/"4$FNJTTJPO$JNNVOJUZ DPNQMZJOHXJUIMPXDPOEVDUFEBOESBEJBUFE emission limitsSFRVJSFECZPGGJDFBOEEBUBDFOUSFFOWJSPONFOUTPG$*413$MBTT"BOEXJUIIJHI FMFDUSPTUBUJDFMFDUSJDBMGJFMEGBTUUSBOTJFOUTVSHFMJHIUOJOHBOESBEJPGSFRVFODZJNNVOJUZMFWFMT PG*&$&/"4SFRVJSFECZCPUIDPNNFSDJBMBOEMJHIUJOEVTUSJBMFOWJSPONFOUT 5FTUBOE1FSGPSNBODF*&$&/"4 $&5IF614DPOGPSNTUPUIFGPMMPXJOH&VSPQFBO$PNNVOJUZEJSFDUJWFT -PX7PMUBHF%JSFDUJWF&&$BNFOEFE&&$ &MFDUSPNBHOFUJD$PNQBUJCJMJUZ%JSFDUJWF&&$BNFOEFE&&$ UP614 UP#BUUFSZ UP614 #BUUFSZ 0 to 95% (non-condensing) 1000 (as per IEC 62040-3) Related Products Mounting Kits 3BDLTMJEFLJUTXBMMNPVOUCSBDLFULJUT BOEUFMFDPNSFMBZSBDLTIFMWFTBSFBWBJMBCMFGPSVTFXJUIUIF-JFCFSU1PXFS4VSF PSI. Liebert MicroPOD™ .BJOUFOBODFCZQBTTTXJUDIUIBUQFSNJUT scheduled maintenance or 614SFQMBDFNFOUXJUIPVUEJTDPOUJOVJOH QPXFSUPDSJUJDBMFRVJQNFOU Liebert IntelliSlot® Web Card %FMJWFST4/.1BOEXFCNBOBHFNFOU communications capability to a Liebert 1PXFS4VSF14*VOJU Liebert NX™ Extended Battery Cabinet -JFCFSU/9FYUFOEFECBUUFSZDBCJOFUTBSF BWBJMBCMFXIFOMPOHFSCBDLVQUJNFJT critical to protected loads. Liebert Maintenance Bypass Cabinet These matching enclosures bolt to the left side of the UPS module and provide “make-before-break” operation to and from maintenance bypass via a single roUBSZTXJUDIXJUIPVUUIFOFFEGPSJOUFSlocking schemes. Liebert IntelliSlot® Web Card The Liebert IntelliSlot Web Card delivers 4/.1BOEXFCNBOBHFNFOUDPNNVOJDBUJPOTDBQBCJMJUZUPB-JFCFSU/9614 Liebert Nform™ A simple to use monitoring and commuOJDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFTOFUXPSLNPOJUPSJOHPGQPXFSBOE DPPMJOHFRVJQNFOU Liebert MultiLink® Shutdown Software -JFCFSU.VMUJ-JOLTPGUXBSFNPOJUPSTCBUUFSZTUBUVTBOEXBSOTVTFSTPGJNQFOEJOH QPXFSMPTTBOEBVUPNBUJDBMMZTIVUTEPXO systems in a safe and orderly manner. Installation And Service 0OMZ&NFSTPODBOQSPWJEFUIFJOEVTUSZµT MBSHFTUNPTUFYQFSJFODFETFSWJDFPSHBOJ[BUJPOXJUIBQSPBDUJWFBQQSPBDIUIBU QSFWFOUTGBJMVSFTBOEFYUFOETFRVJQNFOU life. 55 Knürr Cable Management Related Products – Cable Manaagement *UNVTUCFFOTVSFEXIFOMBZJOHDBCMFTUIBU every kind of mechanical stress is avoided. Bending loads The bending radii may never be less than the values provided by the cable manufacturer in the respective data sheets. At QPJOUTUIBUCFOEUPPNVDIUIFFMFDUSJDBM properties of the cable change and reduce UIFUSBOTNJTTJPOCBOEXJEUITBOESBOHFT If manufacturer specifications are not BWBJMBCMFUIFOUIFGPMMPXJOHSVMFPGUIVNC BQQMJFT 8JUIMPPTFDBCMJOHBUMFBTUUJNFTUIFFYUFSOBMDBCMFEJBNFUFSBOEXJUIGJYFEDBCMJOHBUMFBTU UJNFTUIFFYUFSOBMDBCMF diameter. Kink stress 5IFNPTUFYUSFNFCFOEJOHMPBETDBODBVTF the cable to break. Tensile stress This is only determined by the copper DSPTTTFDUJPOPGUIFDPOEVDUPSBTBMMPUIFS materials are too soft. The cable may not CFTUSFTTFENPSFUIBO/NN2 $VDSPTTTFDUJPO BTPUIFSXJTFUIFDPOEVDtors are stretched and the cross-section is reduced. If higher “pulling” forces are reRVJSFEUIFODBCMFTXJUIBEEJUJPOBMTUSBJO relief elements must be used. Compressive stress Compressive stress is caused by loads beaSJOHEPXOGSPNBCPWFGJYFEDMBNQJOHPS TIBSQDBCMFLJOLJOHBOENVTUBMXBZTCF BWPJEFEBTPUIFSXJTFUIF²MPPTF³DBCMF structure changes and the electrical transmission properties are impaired. Torque strainsUXJTUJOH These must never have an effect on the DBCMFBTUIFZESJWFUIFDBCMFFMFNFOUTJOUP one another and therefore impair the transmission properties. 5IFQSFTDSJCFESBEJJBSFQSFTFUXJUIUIFSBdial limiter. These components ensure that neither a reduction of the transmisTJPOCBOEXJEUITBOESBOHFTOPSBDBCMF break occur. 56 Knürr Di-Strip® EURO Socket System, IEC 320 Knürr Di-Strip® Euro Socket System is featured in these Scenarios: Scenario A 1-2 Racks Single Phase page 10 Scenario B 1-2 Racks Single Phase page 12 Scenario C 3-6 Racks Three Phase page 14 Competitive Advantage Feature Knürr Di-Strip® Material/Finish $BTJOHDMPTFETIFFUTUFFMFYUSVTJPO[JODQMBUFEQPXEFSDPBUFEUFYUVSF 1MBTUJDQBSUT7BNQBNJE706- SFDZDMBCMF Dimensions 4PDLFUTQBDJOHNN)FJHIUNN$BTJOHXJEUINN)6 Approval / Certificates $&-BCFMJOBDDPSEBODFXJUIMPXWPMUBHFEJSFDUJWF&&$&.$%JSFDUJWF &&$*OOPWB(4$#TDIFNF Colour $BTJOH3"-MJHIUHSFZ 1MBTUJDQBSUT3"-EBSLHSFZ Load Rating 7"$" Approval Symbols 7%&63$4" Order Number 03.632.010.1 L mm 483 N F1 Model Up 10 8JUITXJUDI 1 unit Knürr Di-Strip® Triple Power® is featured in these Scenarios: Knürr Di-Strip® Triple Power® Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 Features & Benefits Cost Conscious: Quick and easy mounting on the rackFYUSVTJPO $PTUTSFEVDUJPOXJUISFHBSE to mountingBOEXJSJOH ■ Feed: ■ ■ At a Glance: Y" as standard ■ Installation: Phase assignment colour coding (--- Optimum distribution over the entire rack height TUBOEBSEHU and 41 HU). ■ Ideal for implementing redundancies (e.g. 96 A) Competitive Advantage Feature Knürr Di-Strip® Material/Finish $BTJOHDMPTFETIFFUTUFFMFYUSVTJPO[JODQMBUFEQPXEFSDPBUFEUFYUVSF 1MBTUJDQBSUT7BNQBNJE706- SFDZDMBCMF Dimensions 4PDLFUTQBDJOHNN)FJHIUNN$BTJOHXJEUINN)6 Approval / Certificates $&-BCFMJOBDDPSEBODFXJUIMPXWPMUBHFEJSFDUJWF&&$&.$%JSFDUJWF &&$*OOPWB(4$4"/35-$$#TDIFNF Colour $BTJOH3"-MJHIUHSFZ 1MBTUJDQBSUT3"-EBSLHSFZ Load Rating 7BD*OQVUY"0VUQVU"/"" Approval Symbols 7%&63$4" N F1 Model Up 03.600.024.1 L mm 1033 24 - 1 unit 03.600.048.1 1833 48 - 1 unit 03.600.824.1 1033 24 With plug 1 unit 03.600.848.1 1833 48 With plug 1 unit Order Number 58 Liebert AccuVar® is featured in these Scenarios: Liebert AccuVar® Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 5IF-JFCFSU"DDV7BS4FSJFTJTBNVMUJQIBTFNVMUJNPEFEJTUSJCVtion panel mounted transient voltage surge suppressor (TVSS) that offers continuous protection from damaging transients and electrical line noise. LED lights indicate operation status and an auEJCMFBMBSNXJMMTPVOEJGQSPUFDUJPOCFDPNFTVOBWBJMBCMF3FNPUF NPOJUPSJOHQSPWJEFTBOJOEJDBUJPOPGTVQQSFTTJPOTZTUFNGBJMVSF VOEFSWPMUBHFQIBTFPSQPXFSMPTT Features & Benefits Flexibility: ■ 3FUSPGJUTFBTJMZPOFYJTUJOHQBOFMCPBSET ■ Attaches directly to breaker panel. Higher Availability: ■ .POJUPSTBMMNPEFTPGGBJMVSFJODMVEJOH OFVUSBMUPHSPVOEXJUIQBUFOUFEEFUFDtion circuitry ■ 0GGFSTFBTZTBGFBOENBJOUFOBODFGSFF operation. ■ 3FUSPGJUTFBTJMZUPFYJTUJOHEJTUSJCVUJPO panels Lowest Total Cost Of Ownership: ■ ■ Provides repeatable surge current capability for long product life. 1SPUFDUTZPVSJOWFTUNFOUXJUIBTUBOEBSE XBSSBOUZZFBSTGPSQBSUT Frequently Asked Questions Question Resolution How far away from the panel can the Ac- The Accuvar should be mounted as close as physically possible to the connected panel; cuvar be mounted? General rule is five feet or less. What if a neutral is not available in the panel to connect to? If a neutral terminal is provided in the Accuvar it must be connected to. Make sure the number of conductors needed is determined in advance. Can you use a Delta Accuvar on a Wye system? -JFCFSUNBJOUBJOTBXBSFIPVTFPGQSPEVDUTJO.JTTJTTJQQJGPSRVJDLEJTUSJCVUJPO*OHSBN .JDSPBOE5FDI%BUBBMTPTUPDLNBOZTUBOEBSE-JFCFSU614QSPEVDUTGPSOFYUEBZTIJQment Can the Accuvar be directly connected to the panels bus bars? The Accuvar must be behind the main circuit breaker coming into a facility. A dedicated breaker feeding the TVSS provides an easy means of disconnecting from the QPXFSTPVSDFCVUJTOPUSFRVJSFE What is the recommended breaker and wire size? *UJTSFDPNNFOEFEUIBUUIF"DDVWBSJTDPOOFDUFEUPUIFQBOFMVTJOHHBVHFXJSF and a 30 amp circuit breaker. 59 Accuvar TVSS Technical Specifications Maximum Continuous Operating Voltage (MCOV) 7BMMPUIFST Fault Current Rating (AIC) 200 kAIC 0QFSBUJOH'SFRVFODZ3BOHF °)[ Connection Parallel (10-14 AWG) &.*3'*"UUFOVBUJPO 10 kHz-100MHz (60 dB – Optional) (60 dB – Optional) Response Time <0.5 ns Operating Humidity 0% to 95% Status Indication -&%T"VEJCMF"MBSN4UBOEBSE %SZ$POUBDUT0QUJPOBM Certifications 6-$4"$&/&."-4*40/&."-4*40 Enclosure /&."9 Warranty 10 Years parts Shipping Weight LH UL 1449 second edition clamping data EMI/RFI Noise Rejection Voltage L-N L-G L-L N-G Single Unit Frequency System Installation 400 400 800 400 400 400 400 400 800 400 400 400 X 800 800 240 X 800 800 800 1500 800 800 800 1200 1200 2000 1200 1200 1200 240 X 480 X 1500 1500 X 480 X 1500 600 X 2000 2000 X 600 X 2000 Life Cycle Surge Testing - L"L7*&&&$Bt. C3 Unit Per Mode(L-N/L-G/N-G) Per Phase ACV All Model/Surge Current Nominal (L-G) ACV Voltage Codes ACCUVAR 65kA Per Mode 1 1IBTF-/XHOE 120 120V 208 208V 230 230V 240 240V (must put “-“ in part number) 1IBTF--XHOE (must put “-“ in part number) 7 S 4QMJU1IBTFXHOE ACCUVAR II 346 346V Y 1IBTF8ZFXHOE 80kA 480 480V D 1IBTF%FMUBXHOE Per Mode 600 600V H 1IBTF%FMUB)JMFHXHOE ALL 60 Source Configuration Source Configuration 4UBOEBSE0QUJPOT°3FE(SFFO-&%µT"VR EJCMF"MBSNXJUI&OBCMF%JTBCMF'FBUVSF Standard OptionT&OIBODFE&.*3'*'JMUFRE ring RK 4UBOEBSE0QUJPOT"MBSN3FMBZ$POUBDUT 4UBOEBSE0QUJPOT&OIBODFE&.*3'*'JMUFRKE ring & Alarm Relay Contacts Emerson Network Power – Precision Cooling 5PEBZµTDPNQVUJOHUFDIOPMPHJFTDPNQPVOEDPOWFOUJPOBMDPPMJOH QSPCMFNT#MBEFTFSWFSTDPNNVOJDBUJPOTTXJUDIFTBOEPUIFSFMFDtronics are being packed into tighter and tighter spaces. ComputJOHDBQBDJUZUIBUPODFGJMMFEBOFOUJSFSPPNJTOPXDPOUBJOFEJOB TJOHMFSBDL±DSFBUJOHFYUSFNFQPXFSBOEIFBUEFOTJUJFT 5PTPMWFIFBUEFOTJUZQSPCMFNTUIFHSPXJOHUSFOEBNPOHUPEBZµT IT professionals is an integrated precision cooling solution ±POF that solves both room-level and rack-level cooling challenges. Frequently Asked Questions Question Resolution Provides Protection Under All Conditions :FTDPNQVUFSTIBWFDIBOHFE±CVUUIFUISFBUTUPUIFJSPQFSBUJPOBSFBTSFBMBTFWFS An air conditioning system that maintains the temperature and humidity at the proper levels in your critical facility is an absolute necessity for the viability of your business Keep Moisture And Air Cleanliness Right Where They Need To Be Ordinary building air conditioning and heating systems are designed to keep people DPNGPSUBCMF$PNQVUFSTBOEPUIFSTFOTJUJWFFMFDUSPOJDTSFRVJSFBTZTUFNUIBUQSPWJEFT IVNJEJUZDPOUSPMUPNFFUFRVJQNFOUTQFDJGJDBUJPOT±BOEBJSGJMUSBUJPOEFTJHOFEUP keep airborne particles from causing problems Designed to Meet The Cooling Needs Of Any Critical Space "NJTTJPODSJUJDBMDPPMJOHTZTUFNDBOCFFOHJOFFSFEUPNBUDIKVTUBCPVUBOZUZQFPS TJ[FPGGBDJMJUZ5IFSFBSFEPXOGMPXTZTUFNTGPSSBJTFEGMPPSGBDJMJUJFTBOEVQGMPXVOJUT XIFSFUIFGMPPSTBSFOPUSBJTFE4VQQMFNFOUBMTZTUFNTDBOCFVTFEXIFSFFRVJQNFOU is tightly packed in racks. Compact models are ideal for small or remote facilities. Engineered To Get The Most From Every Energy Dollar &OFSHZFGGJDJFODZJTOPMPOHFSKVTUBOPQUJPOGPSVTFSTPGBJSDPOEJUJPOJOH5PEBZµTTZTUFNTPGGFSBDIPJDFPGDPNQSFTTPSUZQFTNJDSPQSPDFTTPSDPOUSPMTBOEPUIFSPQUJPOBM GFBUVSFTEFTJHOFEUPSFEVDFQPXFSDPOTVNQUJPOBOENBYJNJ[FFOFSHZTBWJOHT Designed To Operate Year-Round #FDBVTFNPTUDSJUJDBMDPNQVUJOHBOEDPNNVOJDBUJPOTGBDJMJUJFTGVODUJPOPOBY CBTJT±TPNVTUUIFFOWJSPONFOUBMFRVJQNFOUUIBUJTQSPUFDUJOHJU.JTTJPODSJUJDBM DPPMJOHJTEFTJHOFEUPSVOBSPVOEUIFDMPDLOPNBUUFSXIBUUIFPVUTJEFXFBUIFSDPOditions 61 Liebert HPM S is featured in these Scenarios: Liebert HPM™ S Cooling Scenario C 3-6 Racks Three Phase page 14 Scenario D 7-10 Racks Three Phase page 16 Liebert HPM S precision air conditioning system provides complete FOWJSPONFOUBMDPOUSPMJODMVEJOHQSFDJTFUFNQFSBUVSFIVNJEJUZ BOEBJSGJMUSBUJPO%FTJHOFEUPGJUJOUIFDSPXEFEDPOGJOFTPGBO FRVJQNFOUSPPNEBUBDFOUFSPSMBCPSBUPSZJUPGGFSTBOFYUSFNFMZ DPNQBDUGPPUQSJOUGPSGBDJMJUJFTXIFSFTQBDFJTBUBQSFNJVN"MMPG UIFDSJUJDBMDPNQPOFOUTBSFBDDFTTJCMFGSPNUIFGSPOUTPUIFVOJU DBOCFJOTUBMMFEJOBDPSOFSPSGMVTIBHBJOTUPUIFSFRVJQNFOU Features & Benefits Flexibility: ■ Small footprint. ■ Total front access for service. ■ Provides a complete environmental conUSPMQBDLBHFJODMVEJOHCPUIQSFDJTJPOBJS conditioning and humidity control. ■ 6QGMPXEPXOGMPXBOEEJTQMBDFNFOU models available. ■ "JSXBUFSHMZDPMBOEDIJMMFEXBUFSVOJUT available. ■ Higher Availability: ■ ■ ■ ■ Advanced microprocessor control. ■ 62 #VJMUXJUI-JFCFSURVBMJUZDPNQPOFOUT from the most trusted name in the industry. Lowest Total Cost Of Ownership: ■ ■ Engineered for year-round operation. Multiple options for communications and real-time monitoring event notification. Reliable hermetic scroll compressor UFDIOPMPHZJODPNCJOBUJPOXJUI stanEBSEIPUHBTCZQBTTHJWFTGMFYJCJMJUZUP BEKVTUUPWBSJPVTSPPNMPBET Optional digital scroll compressor provides continuous load modulation and BEWBODFEGMFYJCJMJUZ ■ ■ Refrigeration system utilizes Scroll comQSFTTPSGPSNBYJNVNFOFSHZFGGJDJFODZ Fast response microprocessor controls NJOJNJ[FTIPSUDZDMJOHBOEPUIFSXBTUFful operating patterns. Liebert precision air conditioning prodVDUTBSFTVQQPSUFECZUIF4FSWJDF/FUXPSLUIFMBSHFTUOFUXPSLPGTFSWJDF QSPWJEFSTJOPVSJOEVTUSZGPSJOTUBMMBUJPO start-up and preventive maintenance. Even more cost effective by using digital TDSPMMDPNQSFTTPSXJUIMPXFSFOFSHZ DPOTVNQUJPOBOEMFTTXFBSBOEUFBS Frequently Asked Questions Question Resolution Why is a Liebert HPM S precision cooling The HPM S offers a much higher level of reliability compared to comfort cooling syssystem better than ordinary building air tems. It uses rugged refrigeration components that are designed to operate 24 hours a EBZEBZTBZFBS5IF-JFCFSU)1.4BMTPQSPWJEFTUIFQSFDJTFUFNQFSBUVSFBOEIVconditioning? NJEJUZDPOUSPMSFRVJSFECZTFOTJUJWFFMFDUSPOJDDPNQVUFSFRVJQNFOU Does this type of cooling system use a lot more energy? Ordinary building air conditioning and heating systems are designed to keep people DPNGPSUBCMF$PNQVUFSTBOEPUIFSTFOTJUJWFFMFDUSPOJDTSFRVJSFBTZTUFNUIBUQSPWJEFT IVNJEJUZDPOUSPMUPNFFUFRVJQNFOUTQFDJGJDBUJPOT±BOEBJSGJMUSBUJPOEFTJHOFEUP keep airborne particles from causing problems Does it take up a lot of room? %FTJHOFEUPGJUJOUIFDSPXEFEDPOGJOFTPGBTNBMMEBUBDFOUFSPSFRVJQNFOUSPPNUIF -JFCFSU)1.4PGGFSTBOFYUSFNFMZDPNQBDUGPPUQSJOUGPSGBDJMJUJFTXIFSFTQBDFJTBUB premium. Does the Liebert HPM S cost more to operate than a regular building air conditioning system? #FDBVTFPGJUTSFMJBCJMJUZDPNQBDUTJ[FBOEFGGJDJFOUFOFSHZVTBHFUIF-JFCFSU)1.4JT BDUVBMMZMFTTFYQFOTJWFUPPQFSBUFPWFSJUTMJGFDZDMFDPNQBSFEUPDPNGPSUDPPMJOHFRVJQment. Competitive Advantage You may be asked about the advantages of the Liebert HPM S cooling system compared to building air conditioning or other types of DPPMJOHTZTUFNT)FSFBSFTPNFJNQPSUBOUEJGGFSFODFTUIBUNBLFUIF-JFCFSUTPMVUJPOUIFSJHIUDIPJDFGPSNBOZBQQMJDBUJPOT Feeature High Reliability Compared to Comfort Cooling Systems 3FMJBCMFSFGSJHFSBUJPODPNQPOFOUTEFTJHOFEUPPQFSBUFIPVSTBEBZEBZTBZFBS Easy Maintenance Front access for easy service access to internal components. Energy Efficient $PNCJOFEXJUIHSFBUFSTFOTJCMFIFBUSFNPWBMUIF-JFCFSU)1.4BMTPVUJMJ[FTBTDSPMM DPNQSFTTPSGPSNBYJNVNFOFSHZFGGJDJFODZ Lower Total Cost of Ownership *OBEEJUJPOUPFOFSHZFGGJDJFODZUIF-JFCFSU)1.4JTEFTJHOFEUPXJUITUBOEUIFUFTUPG time. 63 Liebert HPM™ S Cooling Specifications Liebert HPM S CBTFESFGSJHFSBOU3$ System Type: D-DA= Digital Scroll Compressor; Displacement w/o raised floor Air Cooled with External Condenser Indoor Unit CBTFEPO$3)$BNCJFOU HPM D13DA HPM D23DA Cooling Capacity Data - Standard Air Volume kW kW Total 14.9 26.2 Sensible 13.3 Indoor Cabinet Dimensions -#PUI%% 6OJU)FJHIU%FQUI-FOHUINN Indoor Unit Weight /FU8FJHIULH 240 Indoor Unit Electrical Data - With electric reheat and humidifier (steam-generating) 1PXFS4VQQMZ<7> 6OJU1PXFSJOQVUDPPMJOHPOMZ <L8> 'BO'-"-3"&$GBO <"> $PNQSFTTPS'-"-3"<"> )FBUFS1PXFSJOQVU'-"<L8"> )VNJEJGJFS1PXFSJOQVU'-"<L8"> 7QI)[ Outdoor Unit Condenser - Air Cooled Condensers Model HCE17 for D13DA HCE29 for D23DA 1 /VNCFSPG'BOT 6OJU1PXFS4VQQMZ .BY1PXFS*OQVU<L8> 6OJU'-"-3"<"> 7QI)[ 0.56 Fan Speed Controller included in the internal HPM unit Outdoor Unit Condenser Dimensions $BCJOFUXJUIMFHT )FJHIUY8JEUIY-FOHUI <NN> /FU8FJHIU<LH> YY YY 65 96 5IJTJTKVTUBOFYUSBDUPGUIFXIPMF)1.QSPEVDUSBOHFGPSNPSFJOGPSNBUJPOQMFBTFDBMMZPVSMPDBM-JFCFSUSFQSFTFOUBUJWF Related Products Cold Fire display This display can monitor and set the 6OJUTKVTUQMVHHJOHJUJOUPUIF-"/*UDBO be plugged in case of need or it can be GJYMZJOTUBMMFEPOUIFXBMMPSPOCPBSEPG any Unit. 64 Liebert Nform™ A simple to use monitoring and commuOJDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFTGVMMTDBMFNPOJUPSJOHXJUI cost-effective deployment through the VTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDture. Liebert HPM M-S is featured in these Scenarios: Liebert HPM™ M-L Cooling Scenario E 10-30Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 -JFCFSU)1..-QSFDJTJPODPPMJOHTZTUFNQSPWJEFTFGGJDJFOUQSFDJTFSFMJBCMFDPOUSPMPGSPPNUFNQFSBUVSFIVNJEJUZBOEBJSGMPX GPSQSPQFSPQFSBUJPOPGDSJUJDBMFMFDUSPOJDFRVJQNFOU5IFGMFYJCMF -JFCFSU)1..-PGGFSTIJHIFOFSHZFGGJDJFODZVTFSGSJFOEMZJ$0. DPOUSPMTGSPOUTFSWJDFBDDFTTBOEDPNQSFTTPSPQUJPOT 'PSNPSFJOGPSNBUJPOBCPVUUIJTQSPEVDUBOEJUTBQQMJDBUJPOTDPOtact your local Liebert Representative Features & Benefits Flexibility: ■ "JS8BUFS(MZDPMBOE$IJMMFEXBUFS cooled models. ■ 6QGMPXBOEEPXOGMPXNPEFMTBWBJMBCMF ■ ■ ■ ■ Provides a complete environmental conUSPMQBDLBHFJODMVEJOHCPUIQSFDJTJPOBJS conditioning and humidity control. $IPJDFPGDPNQSFTTPSTJODMVEJOH%JHJUBM Scroll™ and Scroll. Higher Availability: ■ ■ ■ Total front access for service. Liebert iCOM control brings high-level TVQFSWJTJPOUPOFUXPSLJOHNVMUJQMFNJTsion-critical cooling units ■ Lowest Total Cost Of Ownership: #VJMUXJUI-JFCFSURVBMJUZDPNQPOFOUT from the most trusted name in the industry. /FX$PQFMBOE%JHJUBM4DSPMM Compressors stepless variable capacity control for ultimate control and reliability. ■ ■ ™ The Liebert HPM is built for year-around operation. 6TFTFOWJSPONFOUBMMZGSJFOEMZ3DSFfrigerant. R22 as an option. ■ ■ Ultra energy efficient freecooling and Dual Cool hybrid models available. Refrigeration system utilizes Scroll comQSFTTPSGPSNBYJNVNFOFSHZFGGJDJFODZ Even More cost-effective by using Digital TDSPMMDPNQSFTTPSXJUIMPXFSFOFSHZ DPOTVNQUJPOBOEMFTTXFBSBOEUFBS Liebert precision air conditioning products are supported by the Service netXPSLUIFMBSHFTUOBUJPOXJEFOFUXPSLPG service providers in our industry - for inTUBMMBUJPOTUBSUVQBOEQSFWFOUJWFNBJOtenance. 65 Frequently Asked Questions Question Resolution Why is a Liebert HPM precision cooling system better than ordinary building air conditioning? The Liebert HPM offers a much higher level of reliability compared to comfort cooling systems. It uses rugged refrigeration components that are designed to operate 24 IPVSTBEBZEBZTBZFBS5IF-JFCFSU)1.BMTPQSPWJEFTUIFQSFDJTFUFNQFSBUVSF BOEIVNJEJUZDPOUSPMSFRVJSFECZTFOTJUJWFFMFDUSPOJDDPNQVUFSFRVJQNFOU Does this type of cooling system use a lot more energy? /PEVFUPBHSFBUFSTFOTJCMFIFBUSFNPWBMDBQBCJMJUZDPNQBSFEUPBDPNGPSUDPPMJOH TZTUFNPGUIFTBNFTJ[FUIF-JFCFSU)1.XJMMTBWFNPOFZBOEFWFOQBZCBDLQBSUPG your investment over the life of the system. What if you don’t have a raised floor in your data center? 5IF-JFCFSU)1.JTBWBJMBCMFJOVQGMPXNPEFMTGPSVTFJOGBDJMJUJFTXJUIPVUSBJTFEGMPPSJOH BTXFMMBTEPXOGMPXNPEFMTEFTJHOFEUPCFVTFEXJUISBJTFEGMPPST Does the Liebert HPM cost more to operate than a regular building air conditioning system? 4QFDJGJDBMMZEFTJHOFEGPSUIFEFNBOEJOHSFRVJSFNFOUTPGZFBSSPVOEPQFSBUJPOUIF-JFCFSU)1.JTBDUVBMMZMFTTFYQFOTJWFUPPQFSBUFPWFSJUTMJGFDZDMFDPNQBSFEUPCPUI DPNGPSUDPPMJOHFRVJQNFOUBOEDPNQFUJUJWFQSFDJTJPOBJSDPOEJUJPOJOHQSPEVDUT Competitive Advantages You may be asked about the advantages of the Liebert HPM cooling system compared to building air conditioning or other types of DPPMJOHTZTUFNT)FSFBSFTPNFJNQPSUBOUEJGGFSFODFTUIBUNBLFUIF-JFCFSUTPMVUJPOUIFSJHIUDIPJDFGPSNBOZBQQMJDBUJPOT Feeature Wide Choice of Capacities %PXOGMPXNPEFMTGPSSBJTFEGMPPSBQQMJDBUJPOT GSPNL8"JSPS8BUFS(MZDPM DPPMFE PSL8$IJMMFE8BUFS$PPMFE DBQBDJUJFTBOEVQGMPXNPEFMTGPSOPO SBJTFEGMPPSBQQMJDBUJPOT JOL8"JSPS8BUFS(MZDPMDPPMFE PSL8TJ[FT (Chilled Water Cooled). High Reliability Compared to Comfort Cooling Systems 3FMJBCMFSFGSJHFSBUJPODPNQPOFOUTEFTJHOFEUPPQFSBUFIPVSTBEBZEBZTBZFBS Easy Maintenance Front access for easy service access to internal components. Energy Efficient $PNCJOFEXJUIHSFBUFSTFOTJCMFIFBUSFNPWBMUIF-JFCFSU)1.BMTPVUJMJ[FTBEJHJUBM TDSPMMDPNQSFTTPSGPSNBYJNVNFGGJDJFODZ Lower Total Cost of Ownership *OBEEJUJPOUPFOFSHZFGGJDJFODZUIF-JFCFSU)1.4JTEFTJHOFEUPXJUITUBOEUIFUFTUPG time. 66 Liebert HPM™ M-L Cooling Specifications Air-cooled capacity data - 3$SFGSJHFSBOU Model Type Compressor Size D35UA D66UA L99UA 1 Digital Scroll 1 Hermetic Scroll %JHJUBM4DSPMM 2 Hermetic Scroll Cooling Capacity rated at standard air volume DB, ambient 35°C, room conditions 24 °C / 50% RH Total Cooling [kW] 104.6 35 58.4 89.3 YY YY YY 580 1000 Sensible Cooling [kW] Indoor Unit Dimensions and Weights )FJHIUY%FQUIY-FOHUI<NN> Weight [kg] Indoor Unit Electrical Data With electric reheat & humidifier (steam generating) 1PXFS4VQQMZ 7QI)[ 10 19.53 28.83 'BO'-"-3"&$GBO<"> $PNQSFTTPS'-"-3"<"> 6OJU1PXFS*OQVUDPPMJOHPOMZ<L8> )FBUFS1PXFS*OQVU'-"<L8"> )VNJEJGJFS1PXFS*OQVU'-"<L8"> Outdoor Unit Condenser Selection Air-Cooled Condenser Selection Liebert HPM M/L Size Refrigerant 3$ Condenser Type 0VUEPPS-PX/PJTF Ambient Temperature˚C D35UA 35°C 40°C 46°C HCE42 HCE49 )$& D66UA Y)$& Y)$& Y)$& L99UA Y)$& Y)$& Y)$& Outdoor Unit Condenser Dimensions Condenser Cabinet (with legs) Dimensions, mm Size HCE42 HCE49 )$& )$& HCE95 Height 1010 1010 1010 1010 1010 Width 1195 1195 1195 1195 1195 Length 2420 2420 3420 3420 3420 Weight incl.packing (kg) 143 143 206 235 265 5IJTJTKVTUBOFYUSBDUPGUIFXIPMF)1.QSPEVDUSBOHFGPSNPSFJOGPSNBUJPOQMFBTFDBMMZPVSMPDBM-JFCFSUSFQSFTFOUBUJWF Liebert XD Systems are featured in this Scenario: Liebert XD™ Systems Liebert XDC Liebert XDV Adding targeted cooling is more cost-efficient than trying to MPXFSUIFUFNQFSBUVSFPGMPDBMJ[FEIPUTQPUTCZJODSFBTJOHUIF overall room air conditioning capacity. The Liebert XD solution for high heat density cooling applications is a hybrid approach using a combination of floor mount missioncritical cooling units and supplemental cooling from the Liebert XD Series. Scenario F 30-60 Racks Three Phase page 22 Liebert XDH "EEFEBTIFBUMPBETJODSFBTFTVQQMFNFOUBM-JFCFSU9%DPPMJOH DBQBDJUZBMMPXTZPVSSPPNUPBEBQUBTIFBUMPBETSJTF±BMMPXJOH cooling solutions to be added and reconfigured to react to the changes in your environment. Individual systems can improve inUFSJPSBJSGMPXDPPMIPUBJSFKFDUFEGSPNUIFFODMPTVSFPSDPPMIPU spots near the racks. Liebert XD Features & Benefits Flexibility: ■ ■ ■ 'MPPSNPVOUPSSBDLNPVOUNPEVMFT Higher Availability: ■ The Liebert XD solution assures continu- Lowest Total Cost Of Ownership: ■ Total energy savings potential of up to QMVTBDIPJDFPGDPPMJOHDBQBDJUJFTDPWFS ous operation of critical IT systems under DBOCFBDIJFWFEXJUIUIF-JFCFSU9% BOZBQQMJDBUJPOSFRVJSFNFOUT FYUSFNFIFBUDPOEJUJPOT solution. Plug and play for initial installation and ■ %FTJHOFEUPXPSLXJUIUIFIPUBJTMFDPME GVUVSFHSPXUI aisle approach in both raised floor and Can cool more than 30 kW per rack. OPOSBJTFEGMPPSBQQMJDBUJPOTCZFGGJDJFOUMZESBXJOHIPUBJSPVUPGFRVJQNFOU racks and moving cool air into the cold aisle. ■ .JOJNBMGMPPSTQBDFSFRVJSFNFOUTBMMPX NPSFSPPNGPS*5FRVJQNFOU ■ Liebert precision air conditioning products are supported by the Liebert Service /FUXPSLUIFMBSHFTUOFUXPSLPGTFSWJDF QSPWJEFSTJOPVSJOEVTUSZGPSJOTUBMMBUJPO start-up and preventive maintenance. 68 Frequently Asked Questions Question Resolution I already have a cooling system. Why do I need XD? *ONBOZDBTFTIJHIIFBUEFOTJUZIPUTQPUTPS[POFTSFRVJSFUBSHFUFEDPPMJOHTPMVUJPOT The Liebert XD systems are specifically designed to address the higher heat loads that result from implementing blade servers or server consolidation strategies. What are the advantages of pumped refrigerant technology over water-based solutions? "MFBLJOBXBUFSQJQJOHDPOOFDUJPONFBOTUIBUXBUFSDPVMEMFBLJOUPUIFEBUBDFOUFS UIVTDBVTJOHEBNBHFUPFRVJQNFOU*OTUFBEPGXBUFS-JFCFSUVTFTFOWJSPONFOUBM friendly refrigerant R-134a as the coolant in the XD cooling modules. The refrigerant XPVMECFDPNFBHBTJGBMFBLXFSFUPPDDVSUIVTDBVTJOHOPEBNBHFUPUIFFRVJQNFOU XJUIJOUIFTQBDF*OBEEJUJPOUIFQVNQJOHVOJU9%$ DPOUSPMTUIFSFGSJHFSBOUGMVJEUFNQFSBUVSFUPBMXBZTCFBCPWFUIFBDUVBMEFXQPJOUJOUIFSPPNTPOPDPOEFOTBUJPODBO occur. What is the warranty for the ebert XD? 5IF-JFCFSU9%DPNFTXJUIBZFBSXBSSBOUZBOEJTBWBJMBCMFXJUIQSFWFOUJWFNBJOUFOBODFTFSWJDFPQUJPOTUPFOTVSFTNBYJNVNFGGJDJFODZPGZPVSFRVJQNFOU How difficult is installation? Li- The Liebert XD systems are designed as plug-and-play units and can be easily connected and disconnected to refrigerant lines. They can be easily reconfigured as heat densities JOZPVSDPNQVUFSSPPNDIBOHF"EEJUJPOBMMZ-JFCFSUPGGFSTDPNQMFUFJOTUBMMBUJPOBOE start-up services through the largest service organization in our industry. Competitive Advantage :PVNBZCFBTLFEIPXUIF-JFCFSU9%TZTUFNTDPNQBSFUPPUIFSDPPMJOHNFUIPETPSDPNQFUJUJWFQSPEVDUT )FSFBSFTPNFNBKPSBEWBOUBHFT Feeature No Risk of Water Leaks 5IF-JFCFSU9%TZTUFNTVTFQVNQFESFGSJHFSBOUFMJNJOBUJOHSJTLPGMFBLBHFUIBUDBO PDDVSGSPNVTJOHDIJMMFEXBUFS Greater Capacity 5IF-JFCFSU9%7BOE9%)SBUFEDBQBDJUZPGVQUPL8JTBDIJFWFEBUBMPXFSSBUJOH QPJOUMPXFSJOMFUBJSUFNQFSBUVSFTBOEIJHIFSFOUFSJOHGMVJEUFNQFSBUVSFT UIBOPUIFS TZTUFNTUIFSFCZFGGJDJFOUMZQSPWJEJOHNPSFDBQBDJUZUIBOUIFDPNQFUJUJPO Easily Reconfigured 5IF-JFCFSU9%GMFYJCMFDPOOFDUJPOQJQJOHXJUIRVJDLDPOOFDUGJUUJOHTNBLFTUIFTZTUFNT NVDIFBTJFSUPSFDPOGJHVSFBOEFYQBOEUIBOPUIFSUZQFTPGDPPMJOHVOJUTUIBUVTFMJNJUFEGMFYJCJMJUZQMBTUJDQJQJOH Hot Aisle / Cold Aisle Approach "DPNNPOXBZUPJNQSPWFQFSGPSNBODFPGFYJTUJOHSBJTFEGMPPSDPPMJOH BQQMJDBUJPOTIBTCFFOUIF²IPUBJTMFDPMEBJTMF³BQQSPBDI*OUIJTDPOGJHVSBUJPOSPXTPGFRVJQNFOUSBDLTBSFBSSBOHFEJOBMUFSOBUJOHÃIPU³BOEÃDPME³ BJTMFT0OMZUIFDPMEBJTMFTIBWFQFSGPSBUFEGMPPSUJMFTUIBUBMMPXDPPMBJSUP come up from under the raised floor. 5IF-JFCFSU9%VOJUTFOIBODFUIF)PU"JTMF$PME"JTMFBQQSPBDICZGJMMJOH UIFDPMEBJTMFXJUIBJSBUUIFUFNQFSBUVSFSFRVJSFEGPSQSPQFSPQFSBUJPOPG UIFFMFDUSPOJDFRVJQNFOU 7JFXTPG$PNQVUBUJPOBM'MVJE%ZOBNJDT$'% CZ'MVFOU 69 Liebert XDC is featured in this Scenario: Liebert XDC™ Coolant Chiller Scenario F 30-60 Racks Three Phase page 22 The Liebert XDC Coolant Chiller is a specially designed indoor unit UIBUDPOOFDUTEJSFDUMZUP-JFCFSU9%)BOE-JFCFSU9%7VOJUTQSPviding chilled pumped refrigerant circulation and control. The QBDLBHFEVOJUJODMVEFT&ODMPTVSF1VNQT)FBU&YDIBOHFS4DSPMM $PNQSFTTPST3FDFJWFS5BOL$POUSPMT7BMWFTBOE1JQJOH Features & Benefits Flexibility: Higher Availability: ■ Scaleable. ■ "WBJMBCMFJOBJSDPPMFEXBUFSBOEHMZDPM tions and prevents coil condensation by QVNQFESFGSJHFSBOUBOPGGUIFTIFMG configurations. maintaining the coolant being pumped QSPEVDUUIBUPQFSBUFTBUMPXQSFTTVSF to the cooling modules at a temperature and becomes a gas at room tempera- BCPWFUIFSPPNEFXQPJOU"MMGVODUJPOT UVSFTNBLJOHJUJEFBMGPSVTFBSPVOE TVDIBTUFNQFSBUVSFDPOUSPMTXJUDIJOH FMFDUSPOJDFRVJQNFOU ■ The Liebert XDC monitors room condi- Lowest Total Cost Of Ownership: pumps are automatic. ■ "MMGVODUJPOTTVDIBTUFNQFSBUVSFDPO- ■ ■ Floor space efficient. ■ Easy to install. ■ Liebert precision air conditioning prod- USPMBOETXJUDIJOHQVNQTBSFBVUPNBUJD ■ Uses environmentally friendly R-134a BOE3DSFGSJHFSBOU Energy efficient. Uses Liebert XD™ ucts are supported by the Liebert Service /FUXPSLUIFMBSHFTUOFUXPSLPGTFSWJDF QSPWJEFSTJOPVSJOEVTUSZGPSJOTUBMMBUJPO start-up and preventive maintenance. Specifications Liebert XDC /PNJOBM$BQBDJUZ )[L85PO /PNJOBM$BQBDJUZ )[L85PO Input Voltage 7QI)[ Input Voltage 7QI)[ Full load amps " Height ³NN Width ³NN Depth ³NN 8FJHIUFNQUZ LH Related Products Liebert XDV™ "GMFYJCMFIJHIEFOTJUZTQPUBOE[POF cooling system that mounts on the top of the rack taking up zero floor space. Liebert XDH™ "GMFYJCMFIJHIEFOTJUZDPPMJOHTZTUFN UIBUTJUTJOMJOFXJUISBDLFODMPTVSFT Liebert Nform™ A simple to use monitoring and communiDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFT GVMMTDBMFNPOJUPSJOHXJUIDPTUFGGFDUJWF EFQMPZNFOUUISPVHIUIFVTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDUVSF Liebert XDV is featured in this Scenario: Liebert XDV™ Cooling Module Scenario F 30-60 Racks Three Phase page 22 The Liebert XDV Cooling Module mounts vertically above or on the *5SBDLFODMPTVSFESBXJOHIPUBJSGSPNJOTJEFUIFDBCJOFUPSGSPN UIFIPUBJTMF*UUIFODPPMTUIFBJSBOEEJTDIBSHFTJUEPXOUPUIF DPMEBJTMF5IJTTQBDFTBWJOHTPMVUJPOSFRVJSFT[FSPGMPPSTQBDF Liebert XDV Features & Benefits Flexibility: ■ 3FRVJSFTOPGMPPSTQBDF ■ Complements Liebert precision cooling. ■ 1SPWJEFTBOFYDFMMFOUTPMVUJPOGPSTQPU Higher Availability: 6TFTQVNQFESFGSJHFSBOUXIJDIJTJEFBM ■ 0GGFSTGMFYJCMFJOTUBMMBUJPOXJUITFWFSBM connection possibilities. ■ ■ GPSVTFBSPVOEFMFDUSPOJDFRVJQNFOU *ODMVEFTDPJMDPOUSPMTGBOTBOEQJQJOH ■ and zone cooling. ■ Lowest Total Cost Of Ownership: UPMPXFSGBOQPXFS ■ %VBM"BOE# EFUBDIBCMFQPXFSDPSET for increased uptime. ■ Easy to install. ■ Uses zero floor space. ■ Liebert precision air conditioning prod- 5ISFBEFERVJDLDPOOFDUGJUUJOHT BMMPXTBEBQUJWFBOETDBMBCMF Offers superior cooling cost per high density rack due to 100% sensible cooling. GPSBDPNQMFUFQBDLBHFEVOJU ■ 0QFSBUFTXJUIIJHIFOFSHZFGGJDJFODZEVF FYQBOTJPOXJUIPVUJOUFSSVQUJPOPGDPPM- ucts are supported by the Liebert Service ing operation. /FUXPSLUIFMBSHFTUOFUXPSLPGTFSWJDF QSPWJEFSTJOPVSJOEVTUSZGPSJOTUBMMBUJPO start-up and preventive maintenance. Specifications Liebert XDC /PNJOBM$BQBDJUZ)[ L85PO /PNJOBM$BQBDJUZ)[ L85PO /PNJOBM"JSGMPX)[ $'.N3I /PNJOBM"JSGMPX)[ 830 CFM (1410 m3I 7QI)[ 7QI)[ "!7QI)[ "!7QI)[ Input Voltage Full load amps "VEJCMF/PJTF)[)[ E#BE#B4PVOE1PXFS 14” (355 mm) )FJHIUNPEVMFPOMZ Width 23” (581 mm) Depth ³³NN 35 kg 8FJHIUFNQUZ Options 2VJDL$POOFDU$PVQMJOHTGPS'MFYJCMF1JQJOH Condensate Detection (dry contacts) 1 Nominal Capacity Rating is @ 55°F (13°C) Entering Fluid Temperature and 98°F (37°C) Entering Air Temperature. Max capacity 60Hz: XDV10 - 11.8kW @ 106 F (41 C) Max capacity 50Hz: XDV10 - 11.8kW @ 116 F (47 C) Related Products Liebert XDC™ Extreme Density Heat Rejection Specifically designed to support the Liebert XDV and XDH high-density cooling system that removes the heat from the critical space. Liebert Nform™ A simple to use monitoring and commuOJDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFT GVMMTDBMFNPOJUPSJOHXJUIDPTUFGGFDUJWF EFQMPZNFOUUISPVHIUIFVTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDUVSF Liebert XDH is featured in this Scenario: Liebert XDH™ Cooling Module Scenario F 30-60 Racks Three Phase page 22 5IFNPEVMBS-JFCFSU9%))PSJ[POUBMJOUIF3PX$PPMFSJTQMBDFE EJSFDUMZJOMJOFXJUISBDLFODMPTVSFT"JSGSPNUIFIPUBJTMFJTESBXO JOUISPVHIUIFSFBSPGUIFVOJUDPPMFEBOEUIFOEJTDIBSHFE through the front of the unit into the cold aisle. The modular and BEBQUJWFEFTJHOPGUIF-JFCFSU9%)BMMPXTJUUPCFFBTJMZBEEFEBT the demand for cooling increases. Liebert XDH Features & Benefits Flexibility: ■ Higher Availability: 0QUJPOBMQSFDIBSHFEGMFYJCMFQJQJOHXJUI UISFBEFERVJDLDPOOFDUGJUUJOHTBMMPXT ■ Cools more than 30 kW per rack. ■ %VBM"BOE# EFUBDIBCMFQPXFSDPSET BEBQUJWFBOETDBMBCMFFYQBOTJPOXJUIPVU ■ ■ Complements Liebert precision cooling. 1SPWJEFTBOFYDFMMFOUTPMVUJPOGPSTQPU UFSMBDFEDPOOFDUJPOUPUXP9%SFGSJHFS- and zone cooling. ant sources (Liebert XDC) to enhance TVSFDPJMTDPOUSPMTGBOT *ODMVEFTDPJMDPOUSPMTGBOTBOEQJQJOHGPS ■ BOE piping. ■ reliability. 0GGFSTGMFYJCMFJOTUBMMBUJPOXJUITFWFSBM Complete packaged unit includes enclo- Complements Liebert precision ing units. cool- ■ Uses minimal floor space. ■ Easy to install. 5XPQVNQFESFGSJHFSBOUDJSDVJUTBMMPXJO- ■ BDPNQMFUFQBDLBHFEVOJU 0QFSBUFTXJUIIJHIFOFSHZFGGJDJFODZ EVFUPMPXFSGBOQPXFS GPSVTFBSPVOEFMFDUSPOJDFRVJQNFOU connection possibilities. ■ ing. 6TFTQVNQFESFGSJHFSBOUXIJDIJTJEFBM ■ Offers superior cooling cost per high density rack due to 100% sensible cool- ■ 0GGFSTGMFYJCMFJOTUBMMBUJPOXJUITFWFSBM connection possibilities. ■ ■ for increased uptime. interruption of cooling operations. ■ Lowest Total Cost Of Ownership: ■ Liebert precision air conditioning products are supported by the Liebert Service /FUXPSLUIFMBSHFTUOFUXPSLPGTFSWJDF QSPWJEFSTJOPVSJOEVTUSZGPSJOTUBMMBUJPO start-up and preventive maintenance. Knürr CoolLoop® is featured in this Scenario: Knürr CoolLoop® Scenario F page 22 Side-mounted cabinets unit for highly efficient cooling in server cabinets from 10 to 30 kW – XJUITJHOJGJDBOUSFEVDUJPOTJOEBUBDFOUSFFOFSHZDPTUT Knürr CoolLoop® Features & Benefits Flexibility: The Knürr CoolLoop® has a modular TFUVQUIBUDBOCFFRVJQQFEXJUIPOF to four fan units. Cooling is therefore BEBQUFEUPTVJUUIFBDUVBMSFRVJSFNFOU XJUIJOUIFEBUBDFOUSF5IFDPPMJOH range per Knürr CoolLoop® is 10 – 30 L84FMFDUJPOPGUIFSFRVJSFEDBQBDJUZ can be determined by the data centre operator. This ensures investment security for the data centre operaUPSBOEPOMZQSPWJEFTUIFSFRVJSFE DPPMJOHQPXFSSFMBUJWFUPUIFIFBUMPBE produced by the data centre. Higher Availability: The Knürr CoolLoop®makes no comQSPNJTFTXIFOJUDPNFTUPBWBJMBCJMJUZ reliability and safety. The fans are conGJHVSFEXJUIOSFEVOEBODZ5XP Knürr CoolLoops® can be positioned on one server cabinet to meet the IJHIFTUSFRVJSFNFOUTPGBUJFSEBUB centre. This ensures complete 2n redundancy of server cabinet cooling. Lowest Total Cost Of Ownership: The Knürr CoolLoop® represents the highest standards in data room cooling capacities. The main focus is selecting the methods and procedures that save the most energy by using the NPTUNPEFSODPNQPOFOUT5IJTJTXIZUIF USJFEUFTUFEBOEQSPWFO&$GBOUFDIOPMPHZJT used consistently. The air path is constantly monitored and adKVTUFEUISPVHIUIFIFBUFYDIBOHFSTBOENPJTUVSFFMJNJOBUPSTXIJDISFTVMUTJONJOJNVN energy consumption by the fans. The Knürr CoolLoop® not only sets standards XJUISFHBSEUPQSFTTVSFMPTTCVUSFMBUJWFMZIJHI DPMEXBUFSQSFSVOUFNQFSBUVSFGPSPQUJNVN server cooling also ensures improved use of the DPMEXBUFSTZTUFNXJUIBIJHIDPFGGJDJFOUPG performance (COP). The design also enables a high level of free coolJOHXIJDIGBDJMJUBUFTTJHOJGJDBOUTBWJOHTQPUFOUJBMXJUIDPMEXBUFSHFOFSBUJPO4IPSUBJSQBUIT and the arrangement of the fans after the heat FYDIBOHFSBMTPIFMQUPSFEVDFFOFSHZDPOTVNQUJPO This arrangement not only increases the useful MJGFUJNFPGUIFGBOTJUBMTPJODSFBTFTUIFDPPMJOH BJSGMPXWPMVNFBTBSFTVMUPGUIFIJHIFSBJSEFOsity. This in turn conserves resources and further reduces energy consumption. Knürr CoolFlex® is featured in this Scenario: Knürr CoolFlex® page 22 &OFSHZFGGJDJFOUVTFPGFYJTUJOHDPPMJOHQPXFSJOEBUBDFOUFSTXJUI OFXJOTUBMMBUJPOTPSBTJOTUBMMBUJPOGSJFOEMZVQHSBEFTGPSBMMCSBOET The cross braces BSFVTFEGPSTFBMJOHBSFBTPGGBOEQSFDJTFQPTJUJPOJOHBOEBMTPQSPWJEF stability as tilt restraint. Blanking elements DMPTFPGGUIFBSFBTCFUXFFOSBDLTXJUIEJGGFSFOUIFJHIUT Door systems and safety/security %PVCMFEPPSTPSTMJEJOHEPPSTDBOCFDIPTFOGPSUIFGSPOUBOEDMPTF XJUIBVUPNBUJDEPPSDMPTFST*OUIFFWFOUPGBOFNFSHFODZUIFDPME BJTMFDBOCFRVJDLMZFYJUFECFTJNQMZQVTIJOHUIFEPPSTPQFO5IF EPPSTDBOCFGJUUFEXJUIHMBTTPS1MFYJHMBTXJOEPXT Early fire detection BOEFYUJOHVJTIJOH,OSS$PPM'MFYEPFTOPUDBVTFBOZEJTBEWBOtages for most of the early fire detection systems on the market. On UIFDPOUSBSZ*ODPOWFOUJPOBM%$TUIFNJYJOHPGDPMEBOEXBSNBJSDBO DBVTFEFMBZTJOBMBSNTZTUFNT8JUISFHBSEUPGJSFFYUJOHVJTIJOHWBSJPVTTZTUFNTNVTUCFDPOTJEFSFEXIFOJOTUBMMJOHUIF,OSS$PPM'MFY Better work conditions Flexibility: Higher Availability: Raised floor High pressure )JHIWPMVNFGMPX -PXUFNQFSBUVSFT Lowest Total Cost Of Ownership: -PXFSQSFTTVSF -PXFSWPMVNFGMPX Pleasant temperature )JHIWPMVNFGMPXTUPSN High temperature differences DPMEBUCPUUPNXBSNBUUPQ .PSFQMFBTBOU MPXFSWPMVNFGMPX Pleasant temperature Warm aisle Pleasant to high temperature 4PNFXIBUJODSFBTFE temperature All other areas Pleasant temperature Higt temperature Cold aisle Scenario F Specifications XDH20 /PNJOBM$BQBDJUZkW XDH32 22 7PMUBHF1IBTF'SFRVFODZ 30 Physical Data Height - Inches (mm) Width - Inches (mm) 12 (305) Depth - Inches (mm) Weight - (kg) 106 Footprint Unit (m2) 0.33 6OJUXJUI4FSWJDF"SFBN2) 0.42 Warranty Unit Liebert Stand. Labor Liebert Stand. Parts Liebert Stand. Compressor /" Agency Approvals CSA Yes CE Yes Related Products Liebert XDC™ Extreme Density Heat Rejection Specifically designed to support the Liebert XDV and XDH high-density cooling system that removes the heat from the critical space. Liebert Nform™ A simple to use monitoring and commuOJDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFT GVMMTDBMFNPOJUPSJOHXJUIDPTUFGGFDUJWF EFQMPZNFOUUISPVHIUIFVTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDture. Liebert Nform™ Software Liebert Nform™ is featured in these Scenarios: Scenario A 1-2 Racks Single Phase page 10 Scenario B 1-2 Racks Single Phase page 12 Scenario C 3-6 Racks Three Phase page 14 Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 -JFCFSU/GPSNJTBOFUXPSLDPNNVOJDBUJPOTTZTUFNUIBUXJMMFOable you to leverage the distributed monitoring capabilities of ZPVSOFUXPSLDPOOFDUFEFRVJQNFOU5IJTTPGUXBSFTPMVUJPODPNCJOFTGVMMTDBMFNPOJUPSJOHXJUITJNQMFUPVTFEFQMPZNFOUUISPVHI UIFVTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDUVSF*UJTCPUITDBMBCMF BOEBEBQUBCMFTPJUDBOHSPXBTZPVSTZTUFNTFYQBOEBOECVTJOFTT needs change. Features & Benefits Higher Availability: Auto-discovery of Liebert &RVJQNFOU The ability to add multiple device .VMUJQMF/FUXPSL4FHNFOUTDBOCF UZQFTRVJDLMZGPSDFOUSBMJ[FENBOBHF- TDBOOFEGPSOFUXPSLFEFRVJQNFOU ment. Simplified installation and configuraUJPOSFEVDFTPWFSBMMJOTUBMMBUJPOUJNF reducing costs. Supports non-Liebert FRVJQNFOU The ability to monitor and control a XJEFSBOHFPGTVQQPSUTZTUFNT Provides monitoring of systems by multiple vendors eliminating the OFFEGPSSEQBSUZTPGUXBSF Supports current investments PGFYJTUJOHTZTUFNTEFQMPZFEBDSPTT UIFFOUFSQSJTFLFFQJOHDPTUTEPXO Web Integration Simple navigation of monitored systems from a centralized location. /" Eliminates the need for customized interfaces by utilizing the standard interface native to each piece of FRVJQNFOU 44 Base Device Templates Since the device templates are inTUBMMFEXJUIFWFSZ/GPSNTZTUFN NPOJUPSJOHPGOFXFRVJQNFOUJTSFBdily available. As infrastructure changes to the deNBOETPGBGMFYJCMFCVTJOFTTNPEFM UIF/GPSNTPGUXBSFCZEFGBVMUJT ready to adapt to changes to the critical infrastructure. "TBEEJUJPOBMFRVJQNFOUJTEFQMPZFE UIFNPOJUPSJOHPGUIBUFRVJQNFOUJT TJNQMFOPBEEJUJPOBMDPTUJTSFRVJSFE UPBEETZTUFNTUPUIF/GPSN4PGUXBSF Alarm Filtering – Trap 'PSXBSEJOH Filtering of alarms lessens the burden 5IFTPGUXBSFDBOCFDPOGJHVSFEUP POB/FUXPSL.BOBHFNFOU4ZTUFN GPSXBSETQFDJGJDBMBSNTUPB/FUXPSL XJUIOVNFSPVTBMBSNTUIBUPGUFO Management System. hide the critical alarm events. /PXTFOEPOMZBMBSNTUIBUOFFE some type of response. Reduce EPXOUJNFCZGPDVTJOHPOUIFSPPU cause of the immediate incident. Alarm Filtering – Trap 'PSXBSEJOH /PVOEFSTUBOEJOHPG4/.1PS.*#µT SFRVJSFEGPSCBTJDNPOJUPSJOH .PTUTZTUFNTSFRVJSFBHPPEVOEFSTUBOEJOHPG4/.1BOE.*#µT%FWJDF templates remove the technical asQFDUTPGNPOJUPSJOH4/.1CBTFE FRVJQNFOU /PUJGJDBUJPO6QEBUF 8IFOTZTUFNVQUJNFJTJORVFTUJPO /" UPEVFUPQPXFSGMVDUVBUJPOTDBVTJOH CBUUFSZSVOUJNFUIFTPGUXBSFDBO TFOETIVUEPXODPNNBOETUPUIF non-critical system first giving more runtime to system most critical. %FTLUPQ7JFX 2VJDLMZWJFXUIFBWBJMBCJMJUZPGUIF PWFSBMMTZTUFNXJUIBTVNNBSJ[FE WJFX Flexibility: Lowest Total Cost Of Ownership: Feature: /" As alarms are received by the sysUFNOPUJGJDBUJPOSFQPSUTEFUBJMFWFSZ system or individual that has been BMFSUFEBMMPXJOHSFTPVSDFTUPSFspond accordingly and remove the redundancy of alarm reaction. /"1SPWJEFTBEBTICPBSEWJFXPGUIF 5IJTEBTICPBSEWJFXBMMPXTBOJNentire critical management system. mediate response to changes in the DSJUJDBMTZTUFNFOTVSJOHIJHIFSBWBJMBCJMJUZBOESFEVDJOHUIFEPXOUJNF Features & Benefits continued Flexibility: Lowest Total Cost Of Ownership: Feature: Higher Availability: Device Surveillance Ensures the availability of each moni- "TMPOHBTUIFEFWJDFTVQQPSUT4/.1 Some monitoring systems determine UPSFEQJFDFPGFRVJQNFOUCZBDUJWF UIFTZTUFNDBOBDUJWFMZQPMMFRVJQUIFBWBJMBCJMJUZPGFRVJQNFOUCZBTJNmonitor polling. ment and determine the online sta- QMF*$.1QJOH/GPSNEFUFSNJOFTBWBJMtus. BCJMJUZCZ4/.1UFTUJOHUIFJOUFSGBDF that is key to successful monitoring. 5IJTSFEVDFTUIFDPTUBTTPDJBUFEXJUI VOQMBOOFEEPXOUJNFEVFUPGBJMVSFPG alarm notifications. Device Diagnostics Report Diagnostic reports can be run on NPOJUPSFEFRVJQNFOUEFUBJMJOH FBDIDSJUJDBMJOUFSGBDF4/.1*$.1 8&#BOE5FMOFUBOEJUTSFMJBCJMJUZ /" Reporting on system availability and UIFPWFSBMMTUBUFPGNPOJUPSFEFRVJQNFOUBOEBMMJUTJOUFSGBDFTBMMPXT RVJDLFSSFTQPOTFUPQSPCMFNTXJUI UIFTZTUFNSFEVDJOHEPXOUJNFBOE creating a more reliable system. 4IVUEPXOPG8PSLTUBUJPOBOE Servers 8IFOTZTUFNVQUJNFJTJORVFTUJPO EVFUPQPXFSGMVDUVBUJPOTDBVTJOH CBUUFSZSVOUJNFUIFTPGUXBSFDBO TFOETIVUEPXODPNNBOETUPUIF OPODSJUJDBMTZTUFNGJSTUHJWJOHNPSF runtime to the system most critical. 5IFTPGUXBSFDBOCFDPOGJHVSFEUP TFOETIVUEPXOOPUJGJDBUJPOTUPTFSWFSTBOEXPSLTUBUJPOTPOBOZBMBSN event. Increases the runtime for critical FRVJQNFOUPSEFSMZTIVUEPXOTQSFvent the loss of data for key business systems. Communications Loop-Back 5IFTPGUXBSFXJMMFYFDVUFBOJOUFSOBM 4/.15SBQUIBUXJMMCFTFOUPOUIF OFUXPSLBOESFSPVUFECBDLUP /GPSNFOTVSJOHUIFTPGUXBSFJTPQFSating per its configuration and confirming monitoring availability. This loop-back test offers tremenEPVTGMFYJCJMJUZ*UDBOCFTFUVQXJUI any type of notification and configured to run at any time of the day. %VFUPDIBOHFTJOTFDVSJUZQPMJDJFT PGUFOGJSFXBMMTBOEOFXSPVUFSTBSF TFUVQXIJDIQSFWFOUUIFQBTTJOHPG valid communications of alarm FWFOUTGSPNNPOJUPSFEFRVJQNFOU This loop-back test is crucial to availability; reducing the cost associated XJUIEPXOUJNFEVFUPUIFMBDLPGDSJtical alarm notifications. Condition Based Device Commands When changes or fault conditions are JNNJOFOUUIFTPGUXBSFDBOCFDPOfigured to take appropriate actions POUIFNPOJUPSFEFRVJQNFOUBVUPmating the desired reaction such as turning on additional cooling or rebooting of systems. 5IFTPGUXBSFDBOCFDPOGJHVSFEUP UBLFJNNFEJBUFBDUJPOPOFRVJQNFOUUBLJOHBIPMJTUJDBQQSPBch on the overall critical system. .BYJNJ[FTFGGJDJFODZBVUPNBUFTPQerational changes to system to automatically respond to environmental or alarm events. This ultimately reEVDFTUIFDPTUBTTPDJBUFEXJUIEJTpatching personnel to alarm events. Liebert Nform™ Software Frequently Asked Questions Question Resolution Can Liebert Nform shutdown operating systems when an alarm is received, as your Liebert MultiLink software does? :FTCZBEEJOHUIF-JFCFSU.VMUJ-JOLTIVUEPXOMJDFOTF-JFCFSU/GPSNDBOCFTFUVQUP TFOETIVUEPXODPNNBOETUP-JFCFSU.VMUJ-JOLDMJFOUT If I am not using Liebert equipment, can I still use Nform? :FT-JFCFSUDBODVTUPNCVJMEUFNQMBUFTGPSZPVS614TUPXPSLXJUI-JFCFSU/GPSN Do I need a dedicated machine to run the system? /P-JFCFSU/GPSNDBOCFJOTUBMMFEPOZPVSDPNQVUFSUPNBOBHFBGFXEFWJDFT I have a NMS (Network Management System) why do I need Liebert Nform? -JFCFSU/GPSNJTTQFDJGJDBMMZEFTJHOFEUPNBOBHFUIFDSJUJDBMFRVJQNFOUXPSLJOHXJUI BO/.4*UDBOCFVTFEUPGJMUFSBMBSNTBOETFOEPOMZUIFNPTUDSJUJDBMBMBSNTUPBO/.4 Liebert Nform Competitive Advantage Feature Liebert Lock Application -FUTZPVTFMFDUUIFBMBSNUIBUZPVXJTIUPEFMFUFBDLOPXMFEHFJUDMPTFJUVTJOH the tool bar ribbon buttons. Yes Desktop View 1SPWJEFTBEFTLUPQPWFSWJFXPGBMMNBOBHFEEFWJDFT6TFSTDBORVJDLMZJEFOUJGZBMM EFWJDFTPQFSBUJOHOPSNBMMZBOZQSFTFOUBMBSNTBOEBOZEFWJDFTOPUDommunicating properly. Yes Notification Updates 6TFSTDBORVJDLMZWJFXUIFOPUJGJDBUJPOTPOBEFWJDF5IJTDBOCFEJTQMBZFEQFSEFvice. Yes Device Diagnostic Provides a managed device summary report that includes version number of deWJDFBHFOUBMBSNOPUJGJDBUJPOBOEBMBSNTUBUVT5IFSFQPSUXJMMBMTPUFTUFBDIPG UIFDPNNVOJDBUJPOJOUFSGBDFTPOUIFEFWJDF4/.18FC5FMOFU*$.1 Yes Parametric Data View 6TFSDBOWJFXBMMUIF4/.1QBSBNFUSJDEBUBBWBJMBCMFPOUIFEFWJDF Yes Network Statistics 5IFTZTUFNXJMMQSPWJEFUIF/.4TUBUJTUJDBMEBUBPOUIFBHFOUBOEIPXJUQFSGPSNT POUIFDVTUPNFSµTOFUXPSL Yes Alarm Management "MMBMBSNIJTUPSZDBOCFWJFXFEBOENBOBHFE6TFSTDBOWJFXUIFIJTUPSZPGFBDI EFWJDFPSUIFDPNQMFUFTZTUFN6TFSDBOBDLOPXMFEHFBMBSNTBOEBEEDPNNFOUT UPUIFBMBSNTUPEFGJOFXIZBTQFDJGJDFWFOUIBQQFOFE Yes Alarm Definition 6TFSDBOWJFXEFUBJMJOGPSNBUJPOPOFWFOUTPSQBSBNFUSJDEBUBFYQMBJOJOHXIZBO FWFOUIBQQFOFEBOEUIFQBSBNFUSJDEBUBGPSUIFNBOBHFEFRVJQNFOU Yes Auto-Logoff $BOBVUPNBUJDBMMZMPHUIFVTFSPVUPGUIFBQQMJDBUJPO5IJTFTTFOUJBMMZXPSLTMJLFB TDSFFOTBWFS5IFTZTUFNXJMMCFJO²-PDL"QQMJDBUJPO³NPEF Yes Users 5IFTZTUFNTVQQPSUTUXPVTFSTBOBENJOJTUSBUPSBOEQPXFSVTFSBDDFTTMFWFMGPS TZTUFNDPOGJHVSBUJPOPSKVTUBMBSNNBOBHFNFOU Yes 80 Specifications Software Options System Features Liebert Nform Software Liebert Nform Software Liebert Nform Software **Download Edition Professional Edition Enterprise Edition 1 1 1 /P /P 5 8JOEPXT/5X41PSIJHIFS 8JOEPXT/5X41PSIJHIFS 8JOEPXT/5X41PSIJHIFS 8JOEPXT8JOEPXT91 8JOEPXT8JOEPXT91 8JOEPXT8JOEPXT91 8JOEPXT4FSWFS 8JOEPXT4FSWFS 8JOEPXT4FSWFS Yes Yes Yes 1 30 100 Yes Yes Yes -PDBM$MJFOU7JFXFS 3FNPUF$PODVSSFOU$MJFOU7JFXFS Supported Operating Systems Real-Time Monitoring and Control Device Status Polling Default Devices Supported Web Card Integration Open Architecture (Monitoring PGOPOQSPQSJFUBSZ4/.1EFWJDFT Device Template Included Standard RFC1628 UPS Device Template Included Standard RFC1628 UPS Device Template Included Standard RFC1628 UPS Device Device Supported "MM-JFCFSU614&OWJSPONFOUBM 1PXFS%JTUSJCVUJPOBOE Monitoring products that TVQQPSUB4/.1JOUFSGBDF "MM-JFCFSU614&OWJSPONFOUBM 1PXFS%JTUSJCVUJPOBOE Monitoring products that TVQQPSUB4/.1JOUFSGBDF "MM-JFCFSU614&OWJSPONFOUBM 1PXFS%JTUSJCVUJPOBOE Monitoring products that TVQQPSUB4/.1JOUFSGBDF Notifications and Alerts Propagate Application to Foreground Yes Yes Yes -PBE-PDBM7JFXFS Yes Yes Yes Play Sound Wave Yes Yes Yes Play Default Beep Yes Yes Yes 'MBTI"QQMJDBUJPOXIFO.JOJNJ[FE Yes Yes Yes Standard Actions &NBJM/PUJGJDBUJPO Yes Yes Yes 3VO&YUFSOBM1SPHSBN$BQBCJMJUZ Yes Yes Yes Yes Yes Yes "EWBODF/PUJGJDBUJPOT /P /P Unlimited Included 4/.14FU3FRVFTUT /P /P Yes 4/.1(FU3FRVFTUT 3FQPSU /P /P Yes File Write 4IVUEPXO/FUXPSL-JDFOTF Shutdown ML Clients * Note: These add-on packages can be added to the system with Licensing **Software available at no charge at Nform.liebert.com 81 Liebert Nform™ Software Liebert Nform Additional Licenses PART NUMBERS Nform Additional Managed Device Licenses /'03./ /'03./ /'03./ .BOBHFE%FWJDF-JDFOTFLJUTBMMPXUIFVTFSUPJODSFNFOUBMMZBEETVQQPSUGPSNPOJUPSJOH BEEJUJPOBMOVNCFSTPGOFUXPSLEFWJDFT /PEF-JDFOTFTBSFBEEJUJWFBOENBOBHFBCMFUISPVHI-JDFOTF,FZ"ENJOJTUSBUPS Liebert Nform Managed Device Licenses /'03.$64&3 /'03.$64&3 /'03.$64&3 $PODVSSFOU$MJFOU-JDFOTFBMMPXTUIFVTFSUPJODSFNFOUBMMZBEETVQQPSUGPSBEEJUJPOBMOVNCFSTPGDPOOFDUFEDMJFOUT Concurrent Client Licenses are additive and manageable through License Key Administrator. Liebert Nform Advance Notification License /'03."/05*': "EWBODF/PUJGJDBUJPO-JDFOTFBMMPXTUIFVTFSUPBEETVQQPSUGPS4/.14&5(&53FRVFTUT"DUJPOT Liebert MultiLink Network Shutdown License, Unrestricted ® MLLKU -JFCFSU.VMUJ-JOL/FUXPSL4IVUEPXO-JDFOTFBMMPXTZPVUPFGGJDJFOUMZTIVUEPXOXPSLTUBUJPOTBOETFSWFST SVOOJOH-JFCFSU.VMUJ-JOLUISPVHIPVUUIFOFUXPSLWJB&WFOU"MBSNDPOEJUJPOTGSPN-JFCFSU/GPSN Related Products Liebert GXT™ "GBVMUUPMFSBOUOFUXPSLFOBCMFE614 capable of delivering EBUBDFOUFSRVBMJUZQPXFSQSPUFDUJPOUP SBDLTBOETNBMMSPPNT"WBJMBCMFJO BOE 7" Liebert NX™ (40-200kVA) "USVFPOMJOFEPVCMFDPOWFSTJPO NJETJ[FEUISFFQIBTF614TZTUFN UIBUEFMJWFSTDPNQMFUFDFOUSBMJ[F QPXFSQSPUFDUJPOGPSNJTTJPODSJUJDBMTZTtems. Liebert NX™ (10-30 kVA) A compact three-phase true online UPS UIBUPGGFSTQPXFSGBDUPSDPSSFDUJPOGSFRVFODZDPOWFSTJPOJOUFSOBMEZOBNJDCZQBTTJOUFSOBMNBJOUFOBODFCZQBTT TXJUDIJOUFSOBMCBUUFSJFTBEEJUJPOBMCBUUFSZDBCJOFUTJOUFMMJHFOUMPDBMNPOJUPSing and remote communications. Liebert HPM™ Cooling An active precision room cooling system providing a highly energy-efficient soluUJPOJODMVEJOHUFNQFSBUVSFIVNJEJUZ GJMUSBUJPOBOEBJSGMPX Liebert MultiPort4 3FMBZDPOUBDUNVMUJQMFYJOHVOJUDPNNVnicates the On Battery and -PX#BUUFSZTUBUVTPGBTJOHMF614UPDPOOFDUFE1$TTFSWFSTPSXPSLTUBUJPOT5IF VTFSJOTUBMMBCMF IPUTXBQQBCMFDBSEQSPWJEFT614DPNmunications to a host computer and up to four additional computer systems XJUIUIF-JFCFSU*OUFMMJ3BDLNVMUJQMFYJOH VOJUPS614TZTUFNTFRVJQQFEXJUIUIF Liebert IntelliSlot communication port. Liebert IntelliSlot® Webcard %FMJWFST4/.15FMOFUBOE XFCNBOBHFNFOUDBQBCJMJUZGPSFOhanced communications and control of -JFCFSU6141PXFS.BOBHFNFOUPS1SFcision Cooling systems. The card manBHFTBXJEFSBOHFPGPQFSBUJOH QBSBNFUFST BMBSNTBOEOPUJGJDBUJPOTUSBOTNJUUJOH EBUBPWFSUIFOFUXPSL 82 Liebert MultiLink® Automated Shutdown Software Liebert MultiLink® is featured in these Scenarios: Scenario A 1-2 Racks Single Phase page 10 Scenario B 1-2 Racks Single Phase page 12 Scenario C 3-6 Racks Three Phase page 14 Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 Liebert MultiLink is the perfect complement to a Liebert UPS sysUFNQSFWFOUJOHVOFYQFDUFETFSWFSTIVUEPXOTBOENJOJNJ[JOH EPXOUJNF5IFTPGUXBSFQSPWJEFTVOBUUFOEFEPSEFSMZTIVUEPXO GPSPOFDPNQVUFSPSNBOZBOEJTFTQFDJBMMZFGGFDUJWFXJUIMBSHF TFSWFSGBSNT"WBJMBCMFGPSBMMQPQVMBSPQFSBUJOHTZTUFNT-JFCFSU MultiLink has full event management and displays UPS instrumentation on screen. Features & Benefits Flexibility: ■ ■ Full functionality and automated shutEPXOQSPUFDUJPOSJHIUPVUPGUIFCPY± WJSUVBMMZOPDPOGJHVSBUJPOJTSFRVJSFE 0SEFSMZTIVUEPXOPOWJSUVBMMZBOVOMJNited number of computer systems. ■ 6TFSTFMFDUBCMFMBOHVBHFJOUFSGBDF± &OHMJTI$BOBEJBO'SFODI-BUJO"NFSJDBO Spanish and Simplified Chinese. ■ 2VJDLDPOGJHVSBUJPOUISPVHIUIFVOJRVF FWFOUNBOBHFSNBUSJY±GSPNPOFTDSFFO DPOGJHVSFTQFDJGJDFWFOUBDUJPOTXIJMF NBJOUBJOJOHBWJFXPGUIFPWFSBMMTZTUFN configuration. Higher Availability: ■ ■ 4VQQPSUTNVMUJQMFTIVUEPXODPOGJHVSBUJPOTUIBUJODPSQPSBUFOFUXPSLBOETFSJBM CBTFETIVUEPXOTPMVUJPOTGPSPOFPS many computer systems. Includes integration to the Liebert IntelMJ4MPU8FC$BSEXJUI"EBQUFSBOE the Liebert IntelliSlot Web Card interGBDFBEWBODFEBDUJPOMPHHJOHFOIBODFE VOBUUFOEFETIVUEPXODPOGJHVSBUJPOT and support for three-phase UPS systems. Lowest Total Cost Of Ownership: ■ ■ 6TJOHUIFOFUXPSLUPTFOEBMBSNNFTsages and data can dramatically reduce cable and installation costs. Remote management of distributed Liebert MultiLink systems is also available XJUIUIFOFUXPSLBENJOJTUSBUJPOMJDFOTF enabling any Liebert MultiLink installaUJPOPOZPVSOFUXPSLUPCFDPOUSPMMFE from one centralized computer for more FGGJDJFOUNBOBHFNFOUPGZPVSQPXFS protection. Frequently Asked Questions Question Resolution Do I need a Network Administration License for Liebert MultiLink? :PVPOMZOFFEUIF/FUXPSL"ENJOJTUSBUJPO-JDFOTFXIFOZPVBSFNPOJUPSJOHNVMUJQMF 614TPSSFNPUFMZDPOUSPMMJOHPOF-JFCFSU.VMUJ-JOLYXPSLTUBUJPOGSPNBOPUIFS-JFCFSU.VMUJ-JOLYXPSLTUBUJPO Does the Liebert MultiLink Unlimited License work for all of my sites? Each of the Liebert MultiLink License Kits is per one UPS. Each UPS must have a Liebert .VMUJ-JOL-JDFOTF,JUXIFOTIVUUJOHEPXONVMUJQMFDPNQVUFSTTFSWFST 83 Specifications Software Options System Features Type of Monitoring Connection MultiLink 1.5 $POUBDU$MPTVSF4/.1 Multilink Fundamental Version 3.6 4FSJBM$POUBDU$MPTVSF4/.1 Multilink Advanced Version 3.6 4FSJBM$POUBDU$MPTVSF4/.1 1 Graphs /P Yes (Bar) Yes (Bar) Diagnostics Tests /P Yes (Battery) Yes (Battery) Output Control /P Yes Yes Audible Alarm /P Yes Yes #SPBEDBTU/PUJGJDBUJPO /P Yes Yes "VUPNBUFE4IVUEPXO Yes Yes Yes &NBJM/PUJGJDBUJPO /P /P Yes 1BHJOH/PUJGJDBUJPO /P /P Yes Event Based Command Scripts Yes /P Yes Data Logging /P /P Yes Event Logging Yes Yes Yes Action Logging /P Yes Yes HTML Integration (Hot Link to UPS Web Card) /P Yes Yes 1PXFS'MPX7JFX /P Yes Yes 4FDVSF4IVUEPXO0QUJPOT /P Yes Yes 6140O#ZQBTT/PUJGJDBUJPO /P Yes Yes Three-Phase UPS Certification /P Yes Yes (MPCBM/PUJGJDBUJPO"EESFTT#PPL /P /P Yes UPS Alarm Silence /P Yes Yes .VMUJQMF%FWJDF.POJUPSJOH-"/ Yes Yes Yes Multiple Device Monitoring(Out-of-Band) Yes Yes Yes .VMUJQMF$PNQVUFS"VUPNBUFE4IVUEPXO Yes Yes Yes All Models All Models All Models As Previous Version /P Yes Yes UPS Compatibility 4/.15SBQ'PSXBSEJOH Data Integrity 1SPUFDUJOH/FUXPSL5SBOTNJTTJPO&RVJQNFOU $POGJHVSBCMF"MBSN5FYU.FTTBHFT /P Yes Yes /P Yes Yes Alert Message Delay /P Yes Yes Remote Management /P Yes Yes 3FNPUF"DDFTT1BTTXPSE1SPUFDUJPO /P Yes Yes IUUQNVMUJMJOLMJFCFSUDPN IUUQNVMUJMJOLMJFCFSUDPN IUUQNVMUJMJOLMJFCFSUDPN OS Compatibility 1 MultiLink Advanced, version 3.6 can be purchased using part number MLADV. MultiLink Fundamental, version 3.6 can be upgraded to MultiLink Advanced, version 3.6 without the loss of configuration data or installed license files. Related Products Liebert MultiPort4 3FMBZDPOUBDUNVMUJQMFYJOHVOJUDPNNVnicates the On Battery and -PX#BUUFSZTUBUVTPGBTJOHMF614UPDPOOFDUFE1$TTFSWFSTPSXPSLTUBUJPOT5IF VTFSJOTUBMMBCMF IPUTXBQQBCMFDBSEQSPWJEFT614DPNmunications to a host computer and up to four additional computer systems XJUIUIF-JFCFSU*OUFMMJ3BDLNVMUJQMFYJOH VOJUPS614TZTUFNTFRVJQQFEXJUIUIF Liebert Intellislot communication port. 84 Liebert CommSure™ "SFEVOEBOU614JOUFSGBDFUIBUBMMPXT OFUXPSLNBOBHFSTUPDSFBUFUIFJSPXO IJHIBWBJMBCJMJUZQPXFSTZTUFNVTJOHFYisting UPS systems. The system elimiOBUFTGBMTFTIVUEPXOTJHOBMTUIBUPDDVS XIFOTFQBSBUF614TZTUFNTBSFVTFEUP QPXFSDPNQVUFSTXJUISFEVOEBOUQPXFS supplies. Liebert MultiLink® License Kits &OBCMFJOCBOETIVUEPXOPONPSFUIBO POFDPNQVUFSVUJMJ[JOHZPVSFYJTUJOHOFUXPSLJOGSBTUSVDUVSF.VMUJ-JOL-JDFOTF kits decrease installation time and cost removing the need to run additional DBCMFUPFBDITFSWFSPSXPSLTUBUJPOUIBU XJMMCFTIVUEPXO Liebert IntelliSlot® Web Card Liebert IntelliSlot Web Card is featured in these Scenarios: Scenario A 1-2 Racks Single Phase page 10 Scenario B 1-2 Racks Single Phase page 12 Scenario C 3-6 Racks Three Phase page 14 Scenario D 7-10 Racks Three Phase page 16 Scenario E 10-30 Racks Three Phase page 18 Scenario F 30-60 Racks Three Phase page 22 Liebert IntelliSlot Web Card (formerly Liebert OpenComms Web $BSEBOE-JFCFSU0QFO$PNNT/*$$BSE EFMJWFST4/.1BOE8FC NBOBHFNFOUUPB-JFCFSU6141PXFS.BOBHFNFOUPS1SFDJTJPO Cooling system connected to any 10 or 100 Mbit Ethernet netXPSL5IFJOUFSGBDFQSPWJEFTGPSSFNPUFXFCPSJOUIFGJFMEGJSNXBSFVQHSBEF"MBSNTBOEQBSBNFUFSTBSFUSBOTNJUUFEPWFSUIF OFUXPSLVTJOH4/.1FNBJMBOE4.4UFYU*OBEEJUJPO-JFCFSU*OUFMMJ4MPU8FC$BSEX"EBQUFSTVQQPSUT.PECVT Features & Benefits Flexibility: ■ "MMPXTTZTUFNTUPCFWJFXFEGSPNUIF OFUXPSLVTJOHBXFCCSPXTFS ■ %FMJWFST4/.15FMOFUBOEXFCNBOBHFment. ■ ■ Higher Availability: ■ ■ Provides security using HTTPS message encryption. Supports 10 and 100MBit Ethernet for MFHBDZBOENPEFSOOFUXPSLT ■ 1SPWJEFTDPNQBUJCJMJUZXJUI-JFCFSU.VMUJ-JOLTIVUEPXOTPGUXBSFUPQSFWFOUEBUB loss and ensure data availibility. Supports Liebert SiteScan WEB enterQSJTFNPOJUPSJOHTPGUXBSFUPQSPWJEF trending for proactive analysis and maintenance to ensure facility uptime. *OUFSGBDFTXJUI-JFCFSU/GPSNBMBSNOPUJGJDBUJPOTPGUXBSFUPGBDJMJUBUFRVJDLDPSrective action. Lowest Total Cost Of Ownership: ■ "MMPXTVTFPGFYJTUJOHOFUXPSLTBWJOH UIFDPTUPGEFEJDBUFEXJSJOH ■ 3FRVJSFTOPBEEJUJPOBMTPGUXBSFJOTUBMMBtion for basic monitoring. ■ ■ Provides notification in the absence of a comprehensive monitoring system. 1SPWJEFTBTJOHMFQPJOUPGJOGPSNBUJPO control. Frequently Asked Questions Question Resolution What Liebert products are supported by the IS-WEBCARD? -JFCFSU1PXFS4VSF14*MJOFJOUFSBDUJWF614-JFCFSU(95POMJOF614-JFCFSU(95 L7"POMJOF614-JFCFSU(956POMJOF614BOE-JFCFSU/GJOJUZPOMJOF614 What Liebert products are supported by the IS-WEBLB? -JFCFSU/9POMJOF614BOE-JFCFSU)JOFUPOMJOF614 Where can I obtain a user manual for my Liebert IntelliSlot Web Card? IUUQXXXMJFCFSUDPNQSPEVDU@QBHFT1SPEVDUBTQY JE Where can I view and test drive the web interface for the product I am purchasing? IUUQEFNPTMJFCFSUDPN What is the default User Name and Pass- 6TFS/BNF-JFCFSU word for the Liebert IntelliSlot Web 1BTTXPSE-JFCFSU Card? How many SNMP Trap targets can I configure in the Liebert IntelliSlot Web Card? 20 Is the Liebert IntelliSlot Web Card hot-swappable? :FTZPVXJMMOPUCFSFRVJSFEUPTIVUEPXOZPVS614UPJOTUBMMUIJTDBSE Can I obtain a list of the supported SNMP Traps and parameters from the card? :FTPOUIF4VQQPSU5BCPGUIF8FCJOUFSGBDFJTUIF4/.1DBQBCJMJUJFT*OGPSNBUJPOJF 5SBQT&WFOUT1BSBNFUFST *OBEEJUJPOUIJTJOGPSNBUJPOJTBWBJMBCMFWJBUIFTFSJBMDPOnection and Telnet. Consult the User Manual for more details. 85 Competitive Advantage Feature Liebert IS-WEBCARD Enterprise Management System Compatible Yes Fault notification Yes Integrates with system shutdown software Yes Password security Yes Reboot equipment remotely Yes Remote device management (software) Yes SNMP Management Yes UPS MIB (RFC-1628) Support Yes Web Management Yes Secure Web (SSL) Yes Network Firmware Upgrade Yes Email Support Yes Multiple Browser Support Yes Specifications Power Requirements AC Inputs 7"$)[ DC Inputs 7%$7"$)[ 1PXFS$POTVNQUJPO %JNFOTJPOT8Y%Y)JONN 7"NBYJNVN8 YYYY /FU8FJHIUP[LH Shipping Weight - lb. (kg) "NCJFOU0QFSBUJOH&OWJSPONFOU'$ "NCJFOU4UPSBHF5FNQFSBUVSF'$ Protection 1.3 (0.6) 32 to 104 (0 to 40); 10% to 90% RH (non-condensing) -4 to 140 (-20 to 60) 4&-7*TPMBUFE6TFS$POOFDUJPOT8BUDIEPH5JNFS$JSDVJUSZ Communication Ports Service Terminal (RS-232) %#'%5& Ethernet Communications RJ45 Related Products Liebert Nform™ A simple to use monitoring and commuOJDBUJPOTTPGUXBSFTPMVUJPOUIBUDPNCJOFTGVMMTDBMFNPOJUPSJOHXJUI cost-effective deployment through the VTFPGUIFFYJTUJOHOFUXPSLJOGSBTUSVDture. 86 Liebert MultiLink® Shutdown Software -JFCFSU.VMUJ-JOLTPGUXBSFNPOJUPSTCBUUFSZTUBUVTBOEXBSOTVTFSTPGJNQFOEJOH QPXFSMPTTBOEBVUPNBUJDBMMZTIVUTEPXO systems in a safe and orderly manner. Servicing All Your Power And Related Equipment. Your investment in power and cooling equipment is worthless if you do not maintain it. Not even the best equipment can function properly unless it’s serviced with a regular maintenance schedule. &NFSTPO/FUXPSL1PXFSTFSWJDFTUIFDPNQMFUFTQFDUSVN from UPS to precision air systems to batteries and related QPXFSEJTUSJCVUJPOFRVJQNFOU in your data center or in the PUIFSDSJUJDBMGBDJMJUJFTXIFSF continuous availability of systems is essential. 5IFDSJUJDBMFRVJQNFOUXF TFSWJDFJODMVEFT All UPS and Batteries "VUPNBUJD5SBOTGFS4XJUDI 4UBUJD5SBOTGFS4XJUDI System Control Cabinets PDUs Bypass Cabinets 1PXFS$POEJUJPOJOH Precision Air Systems Generators %$1PXFS&RVJQNFOU Delivering Uptime Assurance. &NFSTPO/FUXPSL1PXFSIBTUIFQSPQSJFUBSZUPPMTJOEVTUSZLOPXMFEHFBOESPCVTUTFSWJDFJOGSBTUSVDUVSFUPEFMJWFSSFBMBTTVSBODFUIBUZPVSTZTUFNTXJMMCFBWBJMBCMFXIFOZPVOFFEUIFN0VSHSJEUP DIJQNBJOUFOBODFTUSBUFHZUBLFTBTZTUFNGPDVTFEBQQSPBDIUPZPVSDSJUJDBMFRVJQNFOUTFSWJDFBO BQQSPBDIUIBUHPFTCFZPOETUBOEBSEPGGFSJOHT*UµTBDPNQSFIFOTJWF4FSWJDF4PMVUJPOUIBUMPPLTBU UIFQPXFSBOEDPPMJOHOFFETPGZPVSFOUJSFFOUFSQSJTF"OEIFSFBSFBGFXPGUIFSFBTPOTXFµSFBCMF to deliver on such a promise. The Critical Equipment We Service Includes: %FTJHO4FSWJDFT±"WBJMBCJMJUZBTTFTTNFOUTJOGSBSFEUFTUJOHFMFDUSJDBM UFTUJOHDPPMJOHBTTFTTNFOUTGBDJMJUZQPXFSBVEJUT 1SFWFOUJWF.BJOUFOBODF±3FHVMBSNBJOUFOBODFFOTVSFTUIBUZPVSWJUBM FRVJQNFOUBMXBZTPQFSBUFTBUQFBLQFSGPSNBODF5IJTFYUFOETBWBJMBCJMJUZBOESFEVDFTUPUBMDPTUPGPXOFSTIJQ 1SFEJDUJWF.BJOUFOBODF±1SFEJDUJOHJTTVFTBOEQPUFOUJBMGBJMVSFTCFfore they arise. This creates a more sustainable and dependable netXPSL &OUFSQSJTF3FNPUF.POJUPSJOH±.POJUPSJOHPGBMMZPVSDSJUJDBMTVQQPSU FRVJQNFOUSFHBSEMFTTPGNBOVGBDUVSFS'PSXIFOZPVOFFEUPLOPX XIBUµTIBQQFOJOHJOBMMZPVSGBDJMJUJFT CVUEPOµUIBWFUIFUJNFPSSFTPVSDFT to do it yourself. 88 You’ll Get A Response. And A Resolution. 6OQMBOOFEEPXOUJNFDBOPDDVSBOZEBZBOZUJNF $POGJEFOUDVTUPNFSTLOPXUIFJSDSJUJDBMTZTUFNT TFSWJDFTQBSUOFSXJMMIBWFUIFNCBDLBOESVOOJOH RVJDLMZBOEFGGJDJFOUMZ"GUFSBMMJGEPXOUJNFTIPVME TUSJLFZPVOFFEBQBSUOFSUIBUDBOHFUZPVCBDL POMJOFRVJDLMZXJUIJOUFMMJHFOUBOTXFSTSBQJETFSWJDF SFTQPOTFBOEQBSUTXIFSFBOEXIFOZPVOFFEUIFN We Have The Resources 0VS$VTUPNFS3FTPMVUJPO$FOUFSTVQQPSUTZPVYY*UµTBMXBZT TUBGGFECZLOPXMFEHFBCMFQFPQMFXIPVOEFSTUBOEZPVSUFDIOPMPHZ BOEZPVSFRVJQNFOU/PNFTTBHFT/PBOTXFSJOHTFSWJDFT8FIBOEMF PWFSDBMMTQFSZFBSBOESFTPMWFUIFNJOBOBWFSBHFUJNFPG minutes. We Have The People 5IF4FSWJDF#VTJOFTTPG&NFSTPO/FUXPSL1PXFSIBTUIFDPWFSBHFBOE DBQBCJMJUJFTUPHFUZPVUISPVHIKVTUBCPVUBOZUIJOH8FIBWFUIFNPTU BOEUIFCFTUGBDUPSZUSBJOFE$VTUPNFS&OHJOFFSTJOUIFJOEVTUSZ±PWFS PGUIFNMPDBUFEBDSPTTUIFDPVOUSZ8IBUµTUIBUNFBOUPZPV 0VS BWFSBHFPOTJUFSFTQPOTFUJNFJOXBTKVTUIPVST We Have The Parts 5PNBLFTVSFUIFKPCHFUTEPOFXIFOJUOFFETUPXFIBWFUIFNPTU GBDUPSZDFSUJGJFEQBSUT±BOEUIFNPTUTPQIJTUJDBUFEMPHJTUJDTTZTUFNUP HFUUIFNXIFSFWFSUIFZµSFOFFEFE:PVXPOµUXBJUPOQBSUTUPHFUZPVS TZTUFNVQBOESVOOJOHCFDBVTFOFBSMZPGFNFSHFODZQBSUTPSEFST are delivered in less than 24 hours. 89 90 Emerson Network Power Integrated, Pre-Engieneered Solutions Designed For Your IT-World, Make Energy Efficient. "DIJFWJOHNJTTJPODSJUJDBMOFUXPSL BWBJMBCJMJUZSFRVJSFTUIFJOTUBMMBUJPO NBOBHFNFOUBOEDPOUJOVPVTTVQQPSUPGZPVSOFUXPSLµTJOGSBTUSVDUVSF This continuous availability rests on UIFQPXFSBOEDPPMJOHJOGSBTUSVDUVSFUIBUTVQQPSUTUIFTFTZTUFNT BOESFRVJSFTLFZDPNQPOFOUT - Mission Critical Power - Mission Critical Cooling - Rack and Enclosure Systems - Monitoring and Management - Proactive Maintenance *OBEEJUJPO&NFSTPO/FUXPSL 1PXFSIBTDSFBUFEOFXQPXFS DPPMJOHSBDLBOEFODMPTVSFTZTUFNTBTXFMMBTNPOJUPSJOHTPMVtions that help deliver continuous BWBJMBCJMJUZ±BOESFBMWBMVFCFZPOE the sum of the part. (SFBUFSLOPXMFEHFHBJOPGZPVS needs and ability to meet those needs. 4PMVUJPOTUIBUBSFNPSFSFMJBCMF more comprehensive and more TVJUBCMFUPZPVSOFFET±EFMJWFSJOH greater strategic and operational 8FPGGFSVOTVSQBTTFEBEBQUBCJMJUZ JNQBDUIJHIFSSFMJBCJMJUZGMFYJCJMJUZ BOEMPXFSUPUBMDPTUPGPXOFSTIJQ DVTUPNJ[BUJPOBOEUIFBCJMJUZUP integrate across multiple products $PMMBCPSBUJWFFGGPSUCFOFGJUT± BOETFSWJDFT)FSFBSFTPNFXBZT DPNCJOJOHPVSLOPXMFEHFFYQFSUIBUPVSQPXFSDPPMJOHBOENPOJ- tise and resources to meet your toring solutions create significant needs. WBMVFGPSPVSDVTUPNFST The end result is an infrastructure XJUIUIFBCJMJUZUPBOUJDJQBUFBOE adapt to change. 91 Ensuring The High Availability Of Mission-Critical Cata And Applications. &NFSTPO/FUXPSL1PXFSQSPWJEFTJOOPWBUJWFTPMVUJPOTBOEFYQFSUJTF JOBSFBTTVDIBT"$BOE%$QPXFSTVQQMZQSFDJTJPODPPMJOHTZTUFNT FNCFEEFEDPNQVUFSBOEQPXFSTVQQMZTZTUFNTJOUFHSBUFESBDLT BOEFODMPTVSFTOFUXPSLDJSDVJUTBOEDPOUSPMTNPOJUPSJOHBOE DPOOFDUJWJUZ"MMTPMVUJPOTBSFTVQQPSUFEMPDBMMZBMMPWFSUIFXPSME CZ&NFSTPO/FUXPSL1PXFSDVTUPNFSTFSWJDFUFDIOJDJBOT:PVXJMM ¾OENPSFJOGPSNBUJPOPO&NFSTPO/FUXPSL1PXFSµTQSPEVDUTBOE support services at Locations Emerson Network Power - EMEA 7JB-FPOBSEP%B7JODJ Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy T F NBSLFUJOHFNFB!FNFSTPOOFUXPSLQPXFSDPN www.emersonnetworkpower.com www.eu.emersonnetworkpower.com www.emerson.com www.knuerr.com Emerson Network Power Racks and Solutions Mariakirchener Straße 38 "SOTUPSG (FSNBOZ T F [email protected] Emerson Network Power - USA 1050 Dearborn Drive 10#PY $PMVNCVT0) T Emerson Network Power - Asia '%BI4JOH'JOBODJBM$FOUSF (MPVDFTUFS3PBE8BODIBJ Hong Kong T F While every precaution has been taken to ensure accuracy and completeness in this MJUFSBUVSF&NFSTPO/FUXPSL1PXFSBTTVNFTOPSFTQPOTJCJMJUZBOEEJTDMBJNTBMMMJBCJMJUZ for damages resulting from use of this information or for any errors or omissions. &NFSTPO/FUXPSL1PXFS "MMSJHIUTSFTFSWFEUISPVHIPVUUIFXPSME4QFDJGJDBUJPOTTVCKFDUUPDIBOHFXJUIPVUOPUJDF Emerson Network PowerTM The Global leader in Business-Critical Continuity™ solutions. "$1PXFS Connectivity %$1PXFS Embedded Computing &NCFEEFE1PXFS Infrastructure Management & Monitoring Outside Plant 1PXFS4XJUDIJOH$POUSPMT Precision Cooling Racks & Integrated Cabinets Services Surge Protection #VTJOFTT$SJUJDBM$POUJOVJUZ&NFSTPO/FUXPSL1PXFSBOEUIF&NFSTPO/FUXPSL1PXFSMPHPBSFUSBEFNBSLTBOETFSWJDFNBSLTPG&NFSTPO&MFDUSJD$P&NFSTPO&MFDUSJD$P **(( 1SJOUFEJO(FSNBOZ $PODFQUHSBQIJDTFEJUPSJBM(SPQQ)VCFS 4VCKFDUUPUFDIOJDBMDIBOHFTFSSPSTBOEPNJTTJPOT &NFSTPO/FUXPSL1PXFSBEJWJTJPOPG&NFSTPO/Z4&&.3 JTUIFXPSMEµTMFBEJOHQSPWJEFSPG#VTJOFTT$SJUJDBM$POUJOVJUZ ²(SJEUP$IJQ³TPMVUJPOTGPSUFMFDPNNVOJDBUJPOOFUXPSLTEBUB DFOUFSTNFEJDBMGBDJMJUJFTBOEJOEVTUSJBMTZTUFNT