Download Installation Guide
Transcript
11.3 Spare parts 2 + TR10 IB.3200 IB.3400 IX.3460 IB.3402 IB.4500 GA.3394 IB.4816 IB.5908 IK.3994 GA.3902 GA.6712 TR15 IB.3200 IB.3400 IX.3460 IB.3402 IB.4500 GA.3394 IB.4816 IB.5908 IK.3994 GA.3902 GA.6712 ! TR20 IB.3200 IB.3400 IX.3460 IB.3402 IB.4500 GA.3394 IB.4816 IB.5908 IK.3996 GA.3902 GA.6712 TR24 IB.3200 IB.3400 IX.3460 IB.3402 IB.4500 GA.3394 IX.4200 IB.5908 IK.3996 GA.3902 GA.6712 TR28 IB.3200 IB.3400 IX.3460 IB.3402 IB.4500 GA.3394 IX.4200 IB.5908 IK.3994 GA.3902 GA.6712 TR40 IB.3200 IB.3400 IX.3460 IB.3402 IB.4512 GA.3394 IX.4203 IB.5908 IK.3994 GA.3902 GA.6714 ! TR50 IB.3200 IB.3400 IX.3460 IB.3402 IB.4512 GA.3394 IH.4206 IB.5908 IB.3902 GA.3902 GA.6714 TR60 IB.3200 IB.3400 IX.3460 IB.3402 IB.4516 GA.3394 IX.4200 IB.5908 IB.3902 GA.3902 GA.6716 TR80 IB.3200 IB.3400 IX.3460 IB.3402 IB.4516 IB.3314 IX.4203 IB.5908 IB.3906 GA.3902 GA.6716 TR100 IB.3200 IB.3400 IX.3460 IB.3402 IB.4516 IB.3314 IH.4206 IB.5908 IB.3902 GA.3902 GA.6716 Installer Neutal 12.1 Installation with modulating room thermostat • Connect the heater to 230Vac • Connect the thermostat to the terminals according to the diagram. (terminal 4 and 5) • On the print the switches S2 S2 S3 and S3 need to be set as ON 0 1 follows: S2 switch 1 at the ON 1 2 3 4 5 6 7 8 position, and S3 at 1. L (230V AC) Description Burner Ignition electrode Ignitioncable Ionisation electrode Flue fan Gas controle valve System Fan Controle board 166HA pressureswitch NTC cable set Gasket set TR Thermostat (bus) 22°C 1 2 3 4 5 The changement of these switches need to be performed without power on the Heater, otherwise these settings take no effect. In all cases: make sure you use a screened cable. Cable length: 0 – 50 m min. 0,13 mm2 50 – 100 m min. 0,25 mm2 100 – 250 m (max.) min. 0,50 mm2 The given length is the maximum length between the units and the thermostats. 12.2 Installation of more heaters on one thermostat One room thermostat can control 8 heaters. To connect the heaters is very simple. The two wires for the thermostat can be connected to heater one, from heater one to heater two, from heater two to heater three etc. etc. Connect always on terminal 4 and 5. See also the diagram. Standard factory setting: switch 1 “on” Each heater needs its own unique number to have the heater recognised by the room thermostat. The number of the heater can be set by the micro switch on the heater control HC in the heater. The number at the upper position of the switch is the given number for that heater. Make sure that each heater has is own unique number. If more than one heater have the same number, the system does not work. S2 ON S3 0 1 Heater 1 0 1 Heater 2 0 1 Heater 3 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 The changement of these switches need to be performed without power on the Heater, otherwise these settings take no effect. In all cases: make sure you use a screened cable. Cable length: 0 – 50 m min. 0,13 mm2 50 – 100 m min. 0,25 mm2 100 – 250 m (max.) min. 0,50 mm2 The given length is the maximum length between the units and the thermostats. Instructions Air heaters type TR (GB 122i) Page 15/17