Transcript
PILOT DOOR & ROPE LADDER REEL USER MANUAL PAGE. REV. DATE. 13/17 0 2005-12-19 5. INSPECTION AND SERVICE INTERVALS Daily and (on ships) before departure - Check the free passage of the door and remove obstacles that door from closing. Weekly - Check the hydraulic fluid level. Power units must be discharged first and filled up if necessary. - Check for damage of the sealing surface of the door. - Check the wedges and blocking cones. Lubricate these once again if necessary. Monthly - Check the pressure of the power unit. - Check the operation of the complete system, hand pump. Every two months - Check the setting of the pressure control valves, flow control valve and signaling devices such as pressure switches, proximity switches etc. Hydraulic fluid filter - 1st replacement of the filter after approx. 50 working hours or max. 1 year. - 2nd, 3rd, 4th, etc. replacement of the filter after 250 working hours or max. 4 years. Hydraulic fluid - Renew the hydraulic fluid every 2 years TEL 82-55-345-6110 BYcontrols, Inc. FAX : 82-55-345-6115 E-mail : [email protected] #850-2, Cheongcheon-Ri, Chillye-Myon, Kimhae-City, Keongsangnam-do, Korea