Download MX Component Version 3 Programming Manual

Transcript
3 DETAILS OF THE ACT CONTROLS
MELSOFT
3.3.19 ActCCG4QnA, ActMLCCG4QnA control
The following table indicates the properties possessed by the ActCCG4QnA,
ActMLCCG4QnA control and their default values.
(1) Configuration
(2) Property patterns
Connected
Station CPU
Connected
CC-Link module
station CPU
Relayed
module
Relayed Network
QnACPU
IBM-PC/AT
compatible
QCPU
QCPU
QnA ACPU
FXCPU
(Q mode) (A mode) CPU
1
MELSECNET/H
Relayed network
CC-Link G4
module
(QnA mode)
Relayed Station CPU
MELSECNET/10
Relayed Relayed
station CPU module
MELSECNET(II)
Ethernet
Computer link
CC-Link
: Accessible (Property pattern within circle)
: Inaccessible
1 : Including motion controller CPU
(3) Property list
Property
Property Patterns
2
Default Value
19200
ActBaudRate
(BAUDRATE
BAUDRATE_9600, BAUDRATE_19200, BAUDRATE_38400
_19200)
ActConnectUnitNumber
ActControl
ActCpuType
ActIONumber 1
ActNetworkNumber
ActPortNumber
0
(0x00)
Connected station side CC-Link module station number
8
(TCR_DTR_OR
_RTS)
Depending on used cable.
17
CPU type corresponding to target station
(CPU_Q2ACPU)
1023
(0x3FF)
Fixed to 0x3FF
Fixed to 0x3FF
Fixed to 0x3FF
Connected station
side relayed module
I/O address
0
(0x00)
Fixed to 0x00
Target station side
module network
number
Fixed to 0x00
Fixed to 0x00
1
IBM-PC/AT compatible side COM port number
(PORT_1)
ActStationNumber
255
(0xFF)
ActTimeOut
10000
ActUnitNumber
0
(0x00)
Fixed to 0xFF
Target station side
module station
number
Target station side
module station
number
Fixed to 0xFF
Any value specified by user in ms units
Fixed to 0x00
Fixed to 0x00
Fixed to 0x00
Target station side
module station
number
1: As the I/O address, specify the value found by dividing the actual first I/O number by 16.
2: Note the following points when making access via the Ethernet module (QE71).
• For ActNetworkNumber and ActStationNumber, specify the value set in the parameter setting of the target station side QE71.
• Set the "MNET/10 routing information" in the parameter setting of the QE71. Also, when making setting, specify other than the automatic
response system (any of the IP address calculation system, table conversion system and combined system) as the "MNET/10 routing
system".
3 - 39