Download EPIA-M830_FCC_Report..

Transcript
RV-0000000
Neutron Engineering Inc.
4.2.8 TEST RESULTS-ABOVE 1000MHZ
E.U.T :
Temperature :
Test Voltage :
Test Mode :
Freq.
(MHz)
1200.00
1328.00
1496.00
1608.00
1664.00
1840.00
Ant.Pol.
(H/V)
V
V
V
V
V
V
Mother Board
Model Name :
EPIA-M830
23°C
Relative Humidity : 54%
AC 120V/60Hz
FULL SYSTEM D-SUB 1920*1200/60Hz(CPU 1.3 GHz)
Reading(dBuV)
Peak
AV
54.57
*
50.91
*
60.66
53.46
55.72
*
51.31
*
51.15
*
Ant./CF
CF(dB)
-6.82
-6.11
-5.17
-4.94
-4.83
-4.48
Act.(dBuV/m)
Peak
AV
47.75
*
44.80
*
55.49
48.29
50.78
*
46.48
*
46.67
*
Limit(dBuV/m)
Peak
AV
74.00
54.00
74.00
54.00
74.00
54.00
74.00
54.00
74.00
54.00
74.00
54.00
Note
Remark:
(1) Reading in which marked as PK means measurements by using are Peak Mode with
instrument setting in RBW= 1 MHz, VBW= 1 MHz, Swp. Time = Auto.
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW= 1 MHz, VBW= 10 Hz, Swp. Time = Auto.
(2) All readings are PK Mode value unless otherwise stated AVG in column of『Note』. If the
PK Mode Measured value compliance with the PK Limits and lower than AVG Limits, the
EUT shall be deemed to meet both PK & AVG Limits and then only PK Mode was
measured, but AVG Mode didn‘t perform. In this case, a “ * ” marked in AVG Mode column
of Interference Voltage Measured.
(3) Measuring frequency range above 1000MHz.
Report No.: NEI-FCCE-1-E1004071
Page 23 of 31