Download User Manual

Transcript
Table 4.3 Componentry included in delivery set
№
Name
Labeling
Assignment
Number
Set of delivery
obligatory
1 Pipe nipple
2 Sleeve nut
3 Flange
4 Flange
5 Gasket (paronite)
6 Gasket (paronite)
7 RTD pocket
(LRTС=58mm, type 4)
8 RTD pocket (LRTС
=80mm, type 2)
9 RTD pocket (LRTС
=150mm, type 3)
10 Sealing ring (fluoroplastic)
11 Sealing ring (fluoroplastic)
12 Bush (for angle α=45º)
13 Bush (for angle α=60º)
14 Bush (for angle α=90º)
15 Bush (for angle α=45º)
16 Bush (for angle α=60º)
17 Bush (for angle α=90º)
18 Connecting pipe
(М20x1.5/К3/8”)
19 Gasket
20
21
22
23
24
25
26
27
SMP.302661.002
Connection of FS-32 to a
pipeline (straight-line section)
SMP.758422.001
For mounting FS-32
SMP.711154.004…004-05 (ac- For mounting FS-50…150
2 pcs. per 1
cording to the DN FS)
FS
SMP.711154.008-18…-35 (ac- For mounting FS cording to the DN FS)
200…1000
SMP.754152.009
Sealing of flanges FS-32
SMP.754152.007…007-16
Sealing of flanges FS50…1000
SMP.753137.002-03
Protection of the RТD
from hydraulic impacts
SMP.753137.002-01
Protection of the RТD
from hydraulic impacts
1 pcs. per
1RТD
SMP.302634.002
Protection of the RТD
from hydraulic impacts
SMP.754176.003
Sealing of the RТD
SMP.754176.003-01
SMP.723144.007
SMP.723144.008
SMP.723144.009
SMP.723144.007-01
SMP.723144.008-01
SMP.723144.009-01
SMP.716161.001 (see draft in
Appendix K)
SMP.754156.001
Sealing of thermometer
pocket for RТD
Installation of the RТD
without thermometer pocket
By the
order
+
+
+
+
+
+
+
+
+
+
+
1 pcs. per
1RТD
1 pcs. per 1
Installation of the thermothermometer
meter pocket for RТD
pocket
For pressure sensor mount- 1 pcs. per 1
ing
PS
Sealing of device connec1 pcs.
tor
+
+
+
+
+
+
+
+
Set AB 1000WLV:
+
2 pcs.
- crampon
- corbel
2 pcs.
+
No marking
Mounting of the calculator
- washer «star»
2 pcs.
+
- screw М4 (hex)
2 pcs.
+
Fixings: (thread diameter d and bolt length L fit to holes in flanges and total flange thickness)
- screw М3x10
GOST 17473-80
Mounting of the connector
4 pcs.
+
- washer 3
GOST 10450-78 or 11371-78
4 pcs.
+
Bolts А. (dxL).88.35.019 GOST 7805-70
According to
+
FS-50…-150
the total
Nuts А. (d). 9.35.019
GOST 5927-70
+
number of
Bolts А. (dxL). 46
GOST 7798-70
+
holes in FS
Nuts А. (d). 5
GOST 5915-70
+
flanges
FS-200…-800
Washers (d). 5
GOST 11371-78
+
(App. L and
table 3.3)
5
Structure and functioning of meters
5.1 The principle of heat-carrier (water) flow measurement is ultrasonic time-offlight. The time for the sound to travel between a transmitter and a receiver is measured. The
time difference is proportional to the average fluid velocity and flow rate correspondingly.
The integrated momentary flow rate values give the information about heat-carrier (water)
volume which has passed through FS. The heat-carrier (water) mass is calculated as a function of volume and density of the flow depending on its temperature.
17