Download User Manual
Transcript
Table 4.3 Componentry included in delivery set № Name Labeling Assignment Number Set of delivery obligatory 1 Pipe nipple 2 Sleeve nut 3 Flange 4 Flange 5 Gasket (paronite) 6 Gasket (paronite) 7 RTD pocket (LRTС=58mm, type 4) 8 RTD pocket (LRTС =80mm, type 2) 9 RTD pocket (LRTС =150mm, type 3) 10 Sealing ring (fluoroplastic) 11 Sealing ring (fluoroplastic) 12 Bush (for angle α=45º) 13 Bush (for angle α=60º) 14 Bush (for angle α=90º) 15 Bush (for angle α=45º) 16 Bush (for angle α=60º) 17 Bush (for angle α=90º) 18 Connecting pipe (М20x1.5/К3/8”) 19 Gasket 20 21 22 23 24 25 26 27 SMP.302661.002 Connection of FS-32 to a pipeline (straight-line section) SMP.758422.001 For mounting FS-32 SMP.711154.004…004-05 (ac- For mounting FS-50…150 2 pcs. per 1 cording to the DN FS) FS SMP.711154.008-18…-35 (ac- For mounting FS cording to the DN FS) 200…1000 SMP.754152.009 Sealing of flanges FS-32 SMP.754152.007…007-16 Sealing of flanges FS50…1000 SMP.753137.002-03 Protection of the RТD from hydraulic impacts SMP.753137.002-01 Protection of the RТD from hydraulic impacts 1 pcs. per 1RТD SMP.302634.002 Protection of the RТD from hydraulic impacts SMP.754176.003 Sealing of the RТD SMP.754176.003-01 SMP.723144.007 SMP.723144.008 SMP.723144.009 SMP.723144.007-01 SMP.723144.008-01 SMP.723144.009-01 SMP.716161.001 (see draft in Appendix K) SMP.754156.001 Sealing of thermometer pocket for RТD Installation of the RТD without thermometer pocket By the order + + + + + + + + + + + 1 pcs. per 1RТD 1 pcs. per 1 Installation of the thermothermometer meter pocket for RТD pocket For pressure sensor mount- 1 pcs. per 1 ing PS Sealing of device connec1 pcs. tor + + + + + + + + Set AB 1000WLV: + 2 pcs. - crampon - corbel 2 pcs. + No marking Mounting of the calculator - washer «star» 2 pcs. + - screw М4 (hex) 2 pcs. + Fixings: (thread diameter d and bolt length L fit to holes in flanges and total flange thickness) - screw М3x10 GOST 17473-80 Mounting of the connector 4 pcs. + - washer 3 GOST 10450-78 or 11371-78 4 pcs. + Bolts А. (dxL).88.35.019 GOST 7805-70 According to + FS-50…-150 the total Nuts А. (d). 9.35.019 GOST 5927-70 + number of Bolts А. (dxL). 46 GOST 7798-70 + holes in FS Nuts А. (d). 5 GOST 5915-70 + flanges FS-200…-800 Washers (d). 5 GOST 11371-78 + (App. L and table 3.3) 5 Structure and functioning of meters 5.1 The principle of heat-carrier (water) flow measurement is ultrasonic time-offlight. The time for the sound to travel between a transmitter and a receiver is measured. The time difference is proportional to the average fluid velocity and flow rate correspondingly. The integrated momentary flow rate values give the information about heat-carrier (water) volume which has passed through FS. The heat-carrier (water) mass is calculated as a function of volume and density of the flow depending on its temperature. 17