Download 1070-150 Rev. B5 PQ
Transcript
Chapter 1 Introduction and System Setup Section 1.4 Safety Precautions Most systems also include a personal computer, a sample puck kit, and a helium-transfer kit. You can order other options to expand the capabilities of the base system, including a magnet and either the Model 6700 Magnet Controller or the Model 3120 Magnet Power Supply. The PPMS can be equipped with a 1-T, 7-T, 9-T, 14-T, or 16-T longitudinal magnet or a 7-T transverse magnet. With the exception of 14-T and 16-T longitudinal systems and 7-T transverse systems, PPMS units can operate with one of three different types of dewars: the standard, nitrogen-jacketed, or high-capacity nitrogen-jacketed dewar. Two nitrogen fill ports located on top of the nitrogenjacketed dewar distinguish it from the standard (non-nitrogen-jacketed) dewar. Figure 1-2 illustrates the nitrogen fill ports, and Figures 2-1–2-3 illustrate these three dewars. A liquidnitrogen transfer adapter is included with all nitrogen-jacketed dewars. The probe is the component that is inserted into the dewar. If the system has a longitudinal magnet, the magnet is attached to the probe, as illustrated in Figure 2-4. Any system with a magnet also includes the Model 6700 Magnet Controller or the Model 3120 Magnet Power Supply. Please save the original packing crates for your system so that you can ship components back to Quantum Design for installation of an option, upgrading, or repair. 1.4 Safety Precautions WARNING! The PPMS superconducting magnets produce extremely strong threedimensional magnetic fields that can be dangerous and the PPMS uses cryogenic liquids for temperature control. Critical PPMS-related safety precautions include those for using superconducting magnets, for using cryogenic materials (liquids and gases), and for using electrical equipment, as is reviewed below. Above all, Quantum Design and its staff ask that you use standard safe laboratory procedures. Use common sense. Pay attention to the system’s state and your surroundings. If the behavior of the system appears unusual, something might be wrong with it. If so, take appropriate action. Supervise inexperienced users and train them in general electrical safety procedures. The PPMS has safety features to prevent accidents from causing injury or serious equipment damage. If you use the equipment in a manner that is not specified by Quantum Design, the protection afforded by the equipment could be impaired. Quantum Design PPMS Hardware Manual, 1070-150, Rev. B5 February 2008 1-3