Windows 2008 User Access Control Modification Is Required to Run Certain
SAN/iQ Command Line Interface (CLI) Commands (10145)
Scenario
With Windows 2008 and Windows Vista, there is a new security feature called
User Access Control (UAC). UAC enables additional security confirmation
checks when accessing portions of the operating system that are
considered core.
Any Windows 2008 server configured with the default security settings can
not run the following SAN/iQ CLI commands until the solution below
is applied.
getLocalVolumes
provisionVolume
connectVolume
disconnectLocalVolume
getScsInfo
removeVolume
createKey
Solution
Enable the SAN/iQ CLI to run as an administrator. To do this:
1
Navigate to the SAN/iQ CLI executable, using File Explorer: C:\Program
Files\Common Files\LeftHand Networks\SIQSP.
2
Right click on the SAN/iQ CLI executable, cliq.exe, and select properties.
3
Select the compatibility tab and select “Run this program as an
administrator.”
4
Run the SAN/iQ CLI to execute the commands listed above. Executing
these commands should succeed.