Adjustments
5.5.1
Verify that the cutting angle is 90°
• Make a perpendicular cut on a panel of about 1mt by 1mt.
• Reposition the same panel on the right side and verify that the vertical cut performed
earlier is perfectly parallel with the cutting line.
• If possible use the knob that adjusts the inclination of the left millimetric guide, screwing
it on or off to increase or decrease the angle (fig. 5.60).
Fig. 5.60
Follow this procedure to line the guide supports with the panel:
• Put a rigid panel on the extensions with a straight side leaning on the millimetric
guides.
• Loosen the screws that are behind each millimetric guide and adjust them so that the
panel leans evenly on all.
Electro plexi trim
VERSION: EPlexyT-04-02/2007