Using Oneline Diagrams Shape Select the shape used for substations that are not overriding the Substation Layout Settings. What should be done when identifier text does not fit inside the width As the name of this option suggest, you can choose how the text in the identifier section of the object should be modified if resizing of the substation object causes the text to be too large for the modified size. Extra Substation Fields These four fields, two of which are represented as the Upper Field and Lower Field on the template, can be customized to display any substation field of your choosing. Use the dropdown arrow of the appropriate box to choose a field, or use the Find button to pull up a list of fields to choose from. Once the field has been chosen, set the digits and number of decimal places for the field. Upper-Left Symbol (UL) Choose what symbol to display in the upper-left zone of the substation object. You can choose from None, Switched Shunt, Generator, Number of Buses, and Load. If the substation contains at least one type of the chosen object, a symbol representing that type of object will be displayed in the Upper-Left location of the object to indicate such a presence. By default, the Upper-Left zone will display the Generator symbol. Upper-Right Symbol (UR) Choose what symbol to display in the upper-right zone of the substation object. You can choose from None, Switched Shunt, Generator, Number of Buses, and Load. If the substation contains at least one type of the chosen object, a symbol representing that type of object will be displayed in the Upper-Right location of the object to indicate such a presence. By default, the Upper-Right zone will display the Load symbol. Lower Left Symbol (LL) Choose what symbol to display in the lower-left zone of the substation object. You can choose from None, Switched Shunt, Generator, Number of Buses, and Load. If the substation contains at least one type of the chosen object, a symbol representing that type of object will be displayed in the Lower-Left location of the object to indicate such a presence. By default, the Lower-Left zone will display the number of buses in the substation. Lower-Right Symbol (LR) Choose what symbol to display in the lower-right zone of the substation object. You can choose from None, Switched Shunt, Generator, Number of Buses, and Load. If the substation contains at least one type of the chosen object, a symbol representing that type of object will be displayed in the Lower-Right location of the object to indicate such a presence. By default, the Lower-Right zone will display the Switched Shunt symbol. 80 PowerWorld Simulator Version 13 User’s Guide - September 26, 2007
Related documents
別紙 1-1
プロセレクション史上最高画質へ。 新Epson UltraChrome K3
NEW - エプソン
PW60UserGuide
Generator Automatic Voltage Regulator Operation Manual
MCC-RM001 - Literature Library
SPP TCR MUI User Manual v2.0
Power management. Beautifully simple.
Powerware 30-160kVA Power Supply User Manual
Z8 Encore! XP F6482 Series Product Specification
Power Systems Laboratory User Manual Department of Electrical
Manual - SP Powerworld