Download NXU Lite - AVer USA
Transcript
6. 7. 8. 9. In (5) Abnormal Event to set the condition of the event for system to alarm. System Reboot: when the NVR system reboot without abnormal condition, the system will send out the alarm message. Abnormal Reboot: when the NVR system reboot in irregular condition, the system will send out the alarm message. Recording is switched off: when the recording has been stopped, the system will send out the alarm message. Network is switched off: when the network connection of NVR system is lost, the system will send out the alarm message. Hard Disk failed: when the hard disk doesn’t work normally, the system will send out the alarm message. In (6) Alarm Message to active with external alarm message by your own program. For the detail configuration, please contact the local reseller. In (7) Alarm Button to active manual alarm function. To define alarm message of manually alarm trigger. Click Alarm Button and select the alarm button # and fill in the description of alarm button. To set sensor status of IP camera, click (9) IP Camera Sensor. In IP Camera Alarm Setting window, click High/Low to set sensor status. 116