Every 20,000 Hours of Operation Gearboxes A servo driven gearbox is located at the head of each minor axis. Every 20,000 hours of run time, change the grease in each gearbox. To change the grease: 1. Remove the tool. 2. Rotate the axis for about 15 minutes to warm up the grease and make it flow more easily. 3. Each gearbox has two plugs. Locations vary depending on the gearbox. It may be that both plugs are on the front side, or one plug is on the front and one on the back. Locate the plugs. Make sure the axis is positioned so that the two plugs are aligned vertically. Remove the plugs. 4. Siphon the grease from the lower hole into an acceptable container. Use CAUTION – grease may be HOT! 5. Pump grease into the lower hole so that the grease works its way up into the gears. Refer to the Gearbox Lubrication Quantities chart to determine the type and quantity of lubrication. 6. Replace plugs. Horizontal Vertical Center shaft NOTE: Horizontal/vertical refers to the orientation of the center shaft. 26