Download User`s Manual Template
Transcript
Chapter 12 higher) For T100MD+ and T100MX+ 1 d data (d) is applied to all 3 COMM ports simultaneously and can be any value from 0 to 255 e.g. SETSYSTEM 1, 3 The PLC will wait 3 x 150ms = 450ms for a valid response from the slave controller on all 3 serial ports. 12.64.2 Number of Com Retries # of retries if NETCMD$, READMODBUS, WRITEMODBUS, READMB2 or WRITEMB2 failed to get a valid response from slave controller. 2 dd dd dd dd For Nano-10, FMD and F-series PLCs SETSYSTEM 2, data affects the 4 COMM port individually (COMM4 is Ethernet client connection) , where bit 0 & 1 for COMM1, bit 2 & 3 for COMM2 , bit 4&5 for COMM3 and bit 6&7 for COMM4. By default data is set to &HAA (binary 10 10 10 10). This means 2 re-tries (a total of 3 tries) for all 4 COMM ports. data : dd Comm port : 4 dd dd dd 3 2 1 Where dd = 00, 01, 10, or 11 (maximum = 3 re-try) In order to change the number of retries for COMM2 to 1 retry you have to set the bit 2 & 3 of data. E.g SETSYSTEM 2, &HA5 'binary 10 10 01 10 The above example set COMM2 to 1 retry and the other 3 ports are 2 retries. 2 d For T100MD+ and T100MX+ 12-47