Download User Manual - Western Avionics Ltd
Transcript
6 .4 STACK DATA FORMAT When the Bus Monitor is commanded to start, all messages will be stored before the trigger condition is met. Therefore, all pre-trigger data is captured. The first captured message will start at the address defined by the Start Page Register. All following messages will start on an even PAGE boundary. The STACK data will wraparound after the Finish Page Register value has been exceeded. The format of the messages are shown in table 6-4. Table 6-4 Stack Data Format WORD No. NAME 1 2 3 4 5 : N-4 N-3 N-2 N-1 N Previous Address Pointer Time Stamp HI Time Stamp LO Data Errors : Data Errors RT Response Time 1 (LSB = 0.5 uS) RT Response Time 2 (LSB = 0.5 uS) Next Address Pointer . 6 .4 .1 Previous Address Pointer The first word of each message will define the page address of the previous message. The first message stored will set this pointer to 0000H. 6 .4 .2 Time Stamp HI/LO These two locations are a 32 bit word defining the value of the 32 bit 0.5µS clock when the message started. 6 .4 .3 Da t a These words describe the previous DATA word TYPE, BUS_ID and associated errors as follows: D15 ED D14 0 ED Py Mn Lg Sh =1 =1 =1 =1 =1 U U M R C UM M 111111000666111 R Reeevvv C C D13 0 D12 Py D11 Mn D10 Lg D09 Sh D08 T1 D07 T0 D06 WC Indicates last 1553B word in message. 1553B data word had a Parity error. 1553B data word had a Manchester error. 1553B data word had too many bits (Long). 1553B data word had too few bits (Short). - 67 - D05 B1 D04 B0 D03 NR D02 TA D01 Sy D00 0