Download - Bendix/King
Transcript
NOTE: In steps 6, 7, and 8, repeated presses of F will terminate the update process and bring the display back to the original SET 0 page shown in figure 2-2. U P D A T E D A T A B A S E E R A S I N G D A T A B A S E 9. Press E to acknowledge the estimated load time and begin erasing the existing database. The unit will now display ERASING DATA BASE (figure 2-6). After the database has been erased, loading of the new data begins automatically. As the new data is being loaded, the percentage of transfer is displayed (figure 2-7). SET 0 Figure 2-6 10. Monitor the computer screen. When updating from disks, the computer screen will display “Insert Disk 2 then press any key to continue” when the first disk has been loaded. Disk 1 should now be removed from the disk drive and disk 2 should be inserted. Press any key on the computer. The load operation will continue. If there are 3 disks the computer screen will tell you when to insert disk 3. U P D A T E D A T A B A S E 14 PERCENT COMPLETE SET 0 Figure 2-7 11. The KLN 900 will indicate when the database update is complete as shown in figure 2-8. The computer screen will display the new database expiration date. You may either turn the KLN 900 off at this point or press E to restart the KLN 900. U P D A T E D A T A B A S E UPDATE PUBLISHED DB COMPLETED ACKNOWLEDGE? CRSR ent 12. Remove the interface cable. Turn off the computer. The chances are small of having difficulty updating the database but if you have a problem: Figure 2-8 First check that the interface cable is properly connected and that the computer is turned on. Ensure that the interface cable is firmly inserted into the jack on the front of the KLN900. If there is a problem with the connection or the computer the KLN 900 will display LOADER NOT READY. When the problem is corrected this prompt is removed and the update operation can continue from where it left off. If the wrong disk is inserted the computer screen will display “Incorrect Disk - please insert disk __” where the number 2 or 3 is inserted in the blank. If an internal test fails after the data has been loaded, the KLN 900 will display CHECKSUM ERROR, DATA BASE INVALID, ACKNOWLEDGE?. Press E to acknowledge. The KLN 900 will then display RETRY and EXIT. Use the left outer knob to position the cursor over the desired choice and press E. There are other error messages that may be displayed. If you have a problem that you can’t resolve, write down any error messages to aid your Bendix/King Service Center in identifying the problem. 2-6 Rev 2