BPS / MX / RS Series SCPI Programming Manual 6.6.5 AMETEK Programmable Power Simultaneous Output Phase Measurements You can return simultaneous measurements from all output phases of the source in the three phase mode using the FETCh query. Unlike MEASure queries, FETCh queries do not trigger the acquisition of new data when they are executed. First, you must initiate the measurement trigger system and generate a measurement trigger as explained in the following section "Triggering Measurements". When the measurement data has been acquired by the voltage and current data buffers for each output phase, use INSTrument:NSELect to select each phase, and FETCh to return the specified measurement data. The following commands return rms voltage: INSTrument:NSELect 1 FETCh:VOLTage:AC?;*WAI INSTrument:NSELect 2 FETCh:VOLTage:AC?;*WAI INSTrument:NSELect 3 FETCh:VOLTage:AC?;*WAI 6.6.6 Returning Voltage and Current Data From the Data Buffer The MEASure and FETCh queries can also return all 4096 data values of the instantaneous voltage and current buffers. These are: MEASure:ARRay:CURRent[:DC]?;*WAI MEASure:ARRay:VOLTage[:DC]?;*WAI 6.6.7 Triggering Measurements You can use the data acquisition trigger system to synchronize the timing of the voltage and current data acquisition with an external trigger source. Then use the FETCh commands to return different calculations from the data acquired by the measurement trigger. The following measurement trigger sources can be selected: IMMediate Aquire the measurements immediate SYNChronize Internal to phase A angle BUS IEEE-488 device, *TRG, or <GET> (Group Execute Trigger) TTLTrg The signal driving the Trigger Out Manual P/N 7003-961 Rev. AA 159