Download STATPOINT, LLC
Transcript
Pareto Chart for Defect 120 80.83 frequency 100 96.67 99.17 100.00 91.67 94.17 67.50 80 60 87.50 44.17 40 20 Wrong size Leaking Misshapen Missing parts Rusted Poor color Damaged Misaligned Contaminated 0 Figure 14-5. Enlarged Pareto Chart The vertical bars in the Pareto chart are drawn with height proportional to the number of times each defect type occurred. The line above the bars is a cumulative count from left to right. Shown above each bar is the percentage of defects occurring in a particular class or classes farther to the left. The basic Pareto principle states that a large majority of defects are usually due to a small number of possible causes. In this case, the 3 most frequent defect types account for over 80% of all the defects. 14.3 Crosstabulation The defects.sf6 data file also contains an identification of which facility produced each defective item. To summarize the data by both defect type and facility: 1. If using the Classic menu, select Describe – Categorical Data – Crosstabulation. 2. If using the Six Sigma menu, select Analyze – Attribute Data – Multiple Factors Crosstabulation. The data input dialog box expects two columns, one defining the rows of a two-way frequency or contingency table and the other defining the columns: 222/ Analyzing Attribute Data