A. WINDOW REFERENCE
Start address
[IECUBE]
[Simulator]
Specify the start address.
[IECUBE][Simulator]
This item appears only when [Inside the range (<=Values<=)] or [Outside the range
!(<=Values<=)] is selected in [Compare condition].
End address
[IECUBE]
[Simulator]
Mask value
[Simulator]
Modifying
Directly enter from the keyboard.
Available
values
Address expression within the valid range
Default
The current set value
Modifying
Directly enter from the keyboard.
Available
values
Address expression within the valid range
Specify whether to specify an address mask.
Default
No
Modifying
Select from the drop-down list
Available
values
Yes
Specifies an address mask.
No
Does not specify an address mask.
Specify the value of address mask.
This item appears only when [Use the address mask] is set to [Yes].
Default
The current set value
Modifying
Directly enter from the keyboard.
Available
values
Hexadecimal number up to five digits
[Pass Count] [IECUBE][Simulator]
Specify the pass count condition.
Pass count
Caution
(2)
The current set value
Specify the end address.
[IECUBE][Simulator]
This item appears only when [Inside the range (<=Values<=)] or [Outside the range
!(<=Values<=)] is selected in [Compare condition].
Use the address
mask
[Simulator]
(b)
Default
Specify a pass count.
The relevant event occurs when the event condition is met as many times as the specified pass count.
Default
1
Modifying
Directly enter from the keyboard.
Available
values
1 to 65535 in decimal number
[IECUBE]
A value other than "1" cannot be specified as the pass count condition for an execution-related
event (before execution).
Description area
This area displays a simple description of the item selected in the Event conditions setting area.
R20UT3454EJ0100 Rev.1.00