Download TR TC 032/2013

Transcript
MPa · m 3 ,
- maximum allowable working pressure of over 20 MPa, capacity more than 0.0001 m 3 to 0.001
m 3 inclusive.
Categories receptacles for gases and used working environments for group 1 are shown in Table 1 of Annex
1 to the number of technical regulations;
b) Receptacles for gases, liquefied gases, dissolved under pressure, vapors and used to working fluid in
group 2 and having:
a maximum allowable operating pressure in excess of 0.05 MPa, a capacity greater than 0,001 m 3 and the
product of the maximum allowable working pressure on the value of the capacity of well over 0,005 MPa ·
m3,
maximum allowable working pressure of more than 100 MPa, capacity more than 0.0001 m 3 to 0.001
m 3 inclusive.
Categories receptacles for gases and used for production environments 2 groups are shown in Table 2 of
Annex 1 to the number of technical regulations;
c) intended to contain liquids used for working fluid in group 1 and having:
a maximum allowable operating pressure is above 0.05 MPa capacity of more than 0,001 m 3 and the
product of the maximum allowable working pressure on the value of the capacity of well over 0.02 MPa · m 3 ,
maximum allowable working pressure greater than 50 MPa, capacity over 0.0001 m 3 to 0.001
m 3 inclusive.
Categories receptacles for liquids and used for working environments in group 1 are shown in Table 3 of
Annex 1 to the number of technical regulations;
g) intended to contain liquids used for working fluid in group 2 and having:
a maximum allowable operating pressure in excess of 1 MPa capacity of more than 0.01 m 3 and the product
of the maximum allowable working pressure on the value of capacity, is more than 1 MPa · m 3 ,
maximum allowable working pressure of more than 100 MPa, capacity over 0.0001 m 3 to 0.01
m 3 inclusive.
Categories of vessels designed for liquids and used for working fluid in group 2 are shown in Table 4 of
Appendix 1 to the number of technical regulations;
d) boilers having a capacity of more than 0,002 m 3 , intended to produce hot water at a temperature above
110 0 C, or steam , the excess pressure is above 0.05 MPa, and the vessels of
the fired, having a capacity of more than 0,002 m 3 .
Categories of steam, hot water boilers and fired vessels are shown in Table 5 of Annex 1 to the number of
technical regulations;
e) piping having a maximum allowable operating pressure above 0.05 MPa, a nominal diameter of 25 mm
for gases and vapors are used for working fluid in group 1.
Categories pipelines intended for gases and vapors are used for working fluid in group 1 are shown in Table
2