If the balance is connected externally to PC or Printer through RS 232 C then, whenever user enter into the menu of Density function & make changes in the, automatically printout is generated on the Peripheral attached. In the printout, Temperature, Liquid and Mode are printed. After this user can Press Print Key to Print the reading on the display. Also user can Toggle to other unit through Toggle key & Press Print Key to get the print out of those corresponding units. When GLP ON When GLP OFF Printouts generated when Unit Toggling is done between Application Unit (Den), Unit1 and Unit2 and Reference Weight is changed Printouts generated when Unit Toggling is done between Application Unit (Den), Unit1 and Unit2 and Reference Weight is changed ----------------------------------28-Jul-10 03:19PM Citizen Model CX 220 Ser.no. 9223102 Ver.no. r0.1.5.3 ID 1234567 ----------------------------------Mode GOLD Liquid WATER Temperature 25.0 Pur + 23.1 ct + 18.9350 g + 94.675 ct ----------------------------------28-Jul-10 03:23PM Name: ................ ----------------------------------- Mode Liquid Temperature Pur + + + GOLD WATER 25.0 23.1 ct 18.9350 g 94.675 ct Note : 1) User cannot enter into the external calibration or menu when GLP is ON & footer has not been printed. 2) To print footer user will have to Press <CANCEL> key. 81 If the balance is connected externally to PC or Printer through RS 232 C then, whenever user enter into the menu of Density function & make changes in the, automatically printout is generated on the Peripheral attached. In the printout, Temperature, Liquid and Mode are printed. After this user can Press Print Key to Print the reading on the display. Also user can Toggle to other unit through Toggle key & Press Print Key to get the print out of those corresponding units. When GLP ON Printouts generated when Unit Toggling is done between Application Unit (Den with Compensated Mode Liquid as Ethanol), Unit1 and Unit2 and Reference Weight is changed ----------------------------------28-Jul-10 03:19PM Citizen Model CX 220 Ser.no. 9223102 Ver.no. r0.1.5.3 ID 1234567 ----------------------------------Mode COMPENSATED Liquid ETHANOL Temperature 28.0 Den + 0.6995g/c3 + 18.9350 g + 94.675 ct ----------------------------------28-Jul-10 03:23PM Name: ................ ----------------------------------- When GLP ON Printouts generated when Unit Toggling is done between Application Unit (Den with Uncompensated Mode and Liquid as None), Unit1 and Unit2 and Reference Weight is changed ----------------------------------28-Jul-10 03:19PM Citizen Model CX 220 Ser.no. 9223102 Ver.no. r0.1.5.3 ID 1234567 ----------------------------------Mode UNCOMPENSATED Liquid NONE Temperature NONE Den + 0.6994g/c3 + 18.9350 g + 94.675 ct ----------------------------------28-Jul-10 03:23PM Name: ................ ----------------------------------- Note : 1) User cannot enter into the external calibration or menu when GLP is ON & footer has not been printed. 2) To print footer user will have to Press <CANCEL> key. 82