Download Manual DeviceNet DFD11A Fieldbus interface
Transcript
Sample Application with PLC Type SLC500 4 The following memory areas have been specified with the help of the DeviceNet manager software: *************************************************************************** 1747-SDN Scanlist Map *************************************************************************** Discrete Input Map: I:3.000 I:3.001 I:3.002 I:3.003 I:3.004 I:3.005 I:3.006 I:3.007 I:3.008 I:3.009 I:3.010 I:3.011 I:3.012 I:3.013 I:3.014 I:3.015 I:3.016 I:3.017 I:3.018 I:3.019 I:3.020 I:3.021 I:3.022 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 ------ --- --- --- --- --- --- --- --- --- --- --- --- --- --R R R R R R R R R R R R R R R R Status word of the scanner 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 Process data from device 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 Process data from device 11 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Process data from device 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Process data from device 10 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED1 device 8 polled IO 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED2 device 8 polled IO 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED3 device 8 polled IO 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED1 device 8 bit-strobe IO 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED2 device 8 bit-strobe IO 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 08 PED3 device 8 bit-strobe IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED1 device 0 polled IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED2 device 0 polled IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED3 device 0 polled IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED1 device 0 bit-strobe IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED2 device 0 bit-strobe IO 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 PED3 device 0 bit-strobe IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED1 device 4 polled IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED2 device 4 polled IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED3 device 4 polled IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED1 device 4 bit-strobe IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED2 device 4 bit-strobe IO 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 04 PED3 device 4 bit-strobe IO Discrete Output Map: O:3.000 O:3.001 O:3.002 O:3.003 O:3.004 O:3.005 O:3.006 O:3.007 O:3.008 O:3.009 O:3.010 O:3.011 O:3.012 15 14 13 12 ------ --R R R R 11 11 11 11 10 10 10 10 08 08 08 08 08 08 08 08 08 08 08 08 00 00 00 00 00 00 00 00 00 00 00 00 04 04 04 04 04 04 04 04 04 04 04 04 .. .. .. .. 11 10 --R R 11 11 10 10 08 08 08 08 08 08 00 00 00 00 00 00 04 04 04 04 04 04 .. .. 09 08 07 --- --R R R 11 11 11 10 10 10 08 08 08 08 08 08 08 08 08 00 00 00 00 00 00 00 00 00 04 04 04 04 04 04 04 04 04 .. .. .. 06 05 --R R 11 11 10 10 08 08 08 08 08 08 00 00 00 00 00 00 04 04 04 04 04 04 .. .. 04 03 02 --- --R R R 11 11 11 10 10 10 08 08 08 08 08 08 08 08 08 00 00 00 00 00 00 00 00 00 04 04 04 04 04 04 04 04 04 .. .. .. 01 00 --- --- --- --- --- --- --R R Control word of the scanner 11 11 Process data to device 11 10 10 Process data to device 10 08 08 PAD1 device 8 Polled IO 08 08 PAD2 device 8 Polled IO 08 08 PAD3 device 8 Polled IO 00 00 PAD1 device 0 polled IO 00 00 PAD2 device 0 polled IO 00 00 PAD3 device 0 polled IO 04 04 PAD1 device 4 polled IO 04 04 PAD2 device 4 polled IO 04 04 PAD3 device 4 polled IO .. 08 Bit-strobe for device 8 The polled I/O data are displayed in italics and the bit strobe data in bold italics. MOVIDRIVE® DeviceNet DFD11A 27