If PO2 continues to increase, the value displayed will increase toward
a maximum value of 5,00 ATA in increments of 0,01 ATA. When it
reaches a value of 1,60 ATA, or the PO2 Alarm setting), the Audible Alarm will sound (unless set OFF) and the current PO2 value,
PO2 symbol, O2 segment of the O2 Bar Graph, and UP Arrow with
Bar will flash (Fig. 62) until PO2 decreases below the Alarm setting.
WARNING: In the event that you enter High PO2
Dive Mode, you must immediately focus on reducing the partial pressure of oxygen by slowly Ascending to a shallower depth at a safe rate in accordance with your nitrox training. If you continue the
dive at your current depth, or descend deeper, your
exposure to CNS oxygen toxicity will increase.
While in High PO2 Mode, the Alternate Displays previously described can be accessed using the Advance (Left) button, and the
Backlight can be activated using the Select (Right) button.
NOTE: While in High PO2 Mode, the Voyager will
automatically revert to the Main Display after 3 seconds unless the Advance (Left) button is pressed to
view another Alternate Display of information.
Fig. 62 - PO2 Alarm