Download - AeroLogic

Transcript
42
NNROT
Number of groups of panels whose normals will be tilted to
simulate a control flap deflection (I)
Default: 0
NPEXC
Number of patches excluded from force and moment integration
in DIGITAL WIND TUNNEL [I]
Default: 0
CPWARN
Absolute value of pressure coefficient at which DIGITAL WIND
TUNNEL places a warning in the scroll window and in the .LOG file. The
warning includes a parenthetical (p) or (c) to indicate whether the excessive
pressure appeared on a panel or at a corner point. (R)
Default: 1000
Normal velocity specification -- &BINP11
Format:
&BINP11 NORPCH=1,22 NORF=0,0 NORL=0,0 NOCF=0,0 NOCL=0,0 VNORM=-0.53,0.95
&END
In the following, n indicates NORSET (see &BINP10) values, which are listed
successively, separated by commas. Note that each item needs NORSET values,
even if they are zeroes.
NORPCH(n)
Patch number of patch containing panels to receive a normal
velocity. (I)
Default: 0
NORF(n)
Number of the first row of panels in the defined panel set. Zero
means all rows on this patch. (I)
Default: 0
NORL(n)
Number of the last row of panels in the defined panel set. Zero
means all rows on this patch. (I)
Default: 0
NOCF(n)
Number of the first column of panels in the defined panel set.
Zero means all columns in this patch. [I]
Default: 0
NOCL(n)
Number of the last column of panels in the defined panel set. Zero
means all columns in this patch. [I]
Default: 0