Download FLOWSIC500 Ultrasonic Gas Flow Meter with Optional
Transcript
Installation 3.3.3.2 Torque on the pipeline NOTICE: If the FLOWSIC500 is installed so that the gas flow meter projects sideways from the pipeline, the gas flow meter weight creates a torque on the pipeline. ▸ Make sure the pipeline is capable of holding the gas flow meter → p. 36, Table 10. Table 10 Pipeline torque Meter size DN50/2" DN80/3" DN100/4" DN150/6" [lbf ft] 5 12 23 23 Installation in pipeline 1 Select suitable bolts. Recommended bolts → Table 7. 2 Use the hoisting equipment to position the FLOWSIC500 in the desired location in the pipeline. Lay the pipelines without tension to the device to be installed! 3 Insert and align the gaskets. 4 Apply anti-seize paste to the bolts. 5 First screw the bolts by hand into the adapter to the stop. – Screw in the bolts according to DIN835 with the shorter thread end. – The bolts according to ASME B18.31.2 can be screwed in with any end. 6 Check the thread length in the adapter is fully utilized. 7 Then install the washers and nuts, and tighten them by hand. 8 Check whether the thread length of the nut is fully utilized. If necessary, use a different bolt length. 9 Check correct positioning of flange gaskets. 10 Tighten nuts evenly and crosswise in small steps until the specified tightening torque is reached (→ Table 7). Make sure the flange sits free of tension. 11 Slowly increase the pressure in the pipeline. Gradient: Max. 3bar/min (45psi/min) 12 Carry out a leak tightness check on the pipeline (in accordance with the pipeline manufacturer's specifications). Subject to change without notice 3.3.3.3 Torque [Nm] 6 16 31 31 36 FLOWSIC500 · Operating Instructions · 8015391/YFO2/V 2.2/2015-08 · © SICK AG