1 Specifications Model Number XL1100A Type open chassis AC Line Voltage 115 VAC, ±10%, 50/60 Hz, single phase Line Fuse Rating 15 A Horsepower Range 1/4–1 HP Form Factor 1.05 Maximum Armature Current 5 ADC Maximum Armature Current with Heat Sink* Field Voltage @ 115 VAC Input 10 ADC 50 VDC/100 VDC Maximum Field Current 1 ADC Maximum Armature Voltage Adjustment Range 50–150 VDC Minimum Armature Voltage Adjustment Range 0–70 VDC Acceleration Time Range (with no load) 1–12 seconds Deceleration Time Range (with no load) coast to a stop–12 seconds Speed Adjustment Potentiometer 10K ohms Analog Signal Voltage Range (signal must be isolated; S1 to S2) 0–2.7 VDC Approximate Input Impedance (from S1 to S2) 100K ohms Speed Regulation (at base speed) Safety Certification 1% UL Recognized Component, file E132235 CSA Certified Component, file LR41380 Power Device Switching Frequency Weight Ambient Operating Temperature Range 18 KHz 1.4 lb 10ºC–40ºC *Use heat sink kit part number 223-0271 when continuous armature current is above 5 ADC.