Download User manual EVD evolution twin
Transcript
ENG 13.9 Auxiliary control Parameter/description ADVANCED High Tcond threshold High Tcond integration time ALARM CONFIGURATION High condensing temperature alarm timeout (High Tcond) (0= alarm DISABLED) Auxiliary control can be activated at the same time as main control, and uses the probes connected to inputs S3 and/or S4. Parameter/description CONFIGURATION Auxiliary control: 1=Disabled; 2=High condensing temperature protection on S3 probe; 3=Modulating thermostat on S4 probe; 4=Backup probes on S3 & S4; 5, 6, 7 = Reserved; 8 = Subcooling measurement; 9 = Reverse high condensing temperature protection on S3 Def. Disabled Def. Min. Max. UOM 80 20 -60 (-76) 200 (392) 0 800 °C (°F) s 600 0 s 18000 Tab. 13.j The integration time is set automatically based on the type of main control. • Tab. 13.i • For the high condensing temperature protection (only available with superheat control), an additional pressure probe is connected to S3 that measures the condensing pressure. For the modulating thermostat function (only available with superheat control), an additional temperature probe is connected to S4 that measures the temperature on used to perform temperature control (see the corresponding paragraph). The last option (available if “main control” = 1 to 18) requires the installation of both probes S3 & S4, the first pressure and the second temperature. Note: the protector is very useful in units with compressors on board if the aircooled condenser is undersized or dirty/malfunctioning in the more critical operating conditions (high outside temperature); the protector has no purpose in multiplexed systems (showcases), where the condensing pressure is maintained constant and the status of the individual electronic valves does not affect the pressure value. To reduce the condensing temperature, the output of the refrigeration unit needs to be decreased. This can be done by controlled closing of the electronic valve, implying superheat is no longer controlled, and an increase in the superheat temperature. The protector will thus have a moderate reaction that tends to limit the increase in the condensing temperature, keeping it below the activation threshold while trying to stop the superheat from increasing as much as possible. Normal operating conditions will not resume based on the activation of the protector, but rather on the reduction in the outside temperature. The system will therefore remain in the best operating conditions (a little below the threshold) until the environmental conditions change. Note: if only one backup probe is fitted, under the manufacture parameters, the probe thresholds and alarm management can be set separately. T_EVAP HITCond protection (high condensing temperature) The functional diagram is shown below. MOP_TH MOP_TH - 1 C MOP t ON OFF L P EVD evolution t ON OFF CP S1 S2 S3 F PID S ALARM t ON OFF M D E V EEV P t Fig. 13.h T Key: T_COND HiTcond PID D Fig. 13.g Key: CP C L F S Compressor Condenser Liquid receiver Dewatering filter Liquid indicator EEV V E P T Electronic expansion valve Solenoid valve Evaporator Pressure probe (transducer) Temperature probe • • For the wiring, see paragraph “General connection diagram”. Condensing temperature T_COND_TH HiTcond: threshold High Tcond protection status HiTcond ALARM Alarm PID superheat control t Time Alarm timeout Note: the High Tcond threshold must be greater than the rated condensing temperature of the unit and lower then the calibration of the high pressure switch; the closing of the valve will be limited if this causes an excessive decrease in the evaporation temperature. As already mentioned, the HITCond protection can only be enabled if the controller measures the condensing pressure/temperature, and responds moderately by closing the valve in the event where the condensing temperature reaches excessive values, to prevent the compressor from shutting down due to high pressure. The condensing pressure probe must be connected to input S3. 63 “EVD Evolution TWIN” +0300006EN - rel. 2.4 - 15.02.2015