Download User Manual - Quinn

Transcript
SPC Variable Control Charts 161
Control Limits for the MR part of the MAMR (Moving Average/Moving
Range Chart
Control Limits for the R-Chart
_
UCL
=
R + D4 *
Center line
=
_
R
LCL
=
0
_
R
_
R in this case is the average of the moving ranges.
Where the constant D4 is tabulated in every SPC textbook for various sample sizes.
Control Limits for the MS part of the MAMS (Moving Average/Moving
Sigma Chart
UCL
=
_
B4 *
Center line
=
_
S
LCL
=
_
B3 *
_
S
_
S
_
S in this case is the average of the moving sigmas.
Where the constant B4 is tabulated in every SPC textbook for various sample sizes.
The software does not calculate an optimal Nvalue; that is up to you, the programmer to supply,
based on your past experience with MA charts.
For the values of zi where i < N-1, the weighted average and control limits are calculated using
the actual number of samples used in the average, rather than N. This results in expanded values
for the control limits for small i < N-1.
You specify N, the length of the moving average, immediately after the initialization call
initSPCTimeVaraibleControlChart (for a time-based variable control chart), or
initSPCBatchVariableControlChart (for a batch-based variable control chart). Set the