Download QuickSpecs
Transcript
QuickSpecs HP 9000 Superdome Servers (PA-8600, PA-8700, PA8800 and PA-8900) Configuration Redundant and hotswap DC converters for the crossbar backplane ASIC full burn-in and "high quality" production process Full "test to failure" and accelerated life testing on all critical assemblies Strong emphasis on quality for multiple-nPartition single points of failure (SPOFs) System resilience to Management Processor (MP) Isolation of nPartition failure Protection of nPartitions against spurious interrupts or memory corruption Hot swap redundant fans (main and I/O) and power supplies (main and backplane power bricks) Dual power source Phone-Home capability "HA Cluster-In-A-Box" Configuration: Configuration The "HA Cluster-In-A-Box" allows for failover of users' applications between hardware partitions (nPars) on a single Superdome system. All providers of mission critical solutions agree that failover between clustered systems provides the safest availability-no single points of failures (SPOFs) and no ability to propagate failures between systems. However, HP supports the configuration of HA cluster software in a single system to allow the highest possible availability for those users that need the benefits of a non-clustered solution, such as scalability and manageability. Superdome with this configuration will provide the greatest single system availability configurable. Since no single-system solution in the industry provides protection against a SPOF, users that still need this kind of safety and HP's highest availability should use HA cluster software in a multiple system HA configuration. Multiple Serviceguard or Serviceguard Extension for RAC clusters can be configured within a single Superdome system (i.e., two 4-node clusters configured within a 32-processor Superdome system). Multi-system High Availability Any Superdome partition with PA-RISC processors that is protected by Serviceguard or Serviceguard Extension for RAC can be configured in a cluster with: Another Superdome with PA-RISC processors One or more standalone non Superdome systems with PA-RISC processors Another partition within the same single cabinet Superdome (refer to "HA Cluster-in-a-Box" above for specific requirements) Separate partitions within the same Superdome system can be configured as part of different Serviceguard clusters. Please note that when you add nodes or initially create a cluster, all nodes must be at the same version of the operating system and Serviceguard. This means that you may have to load an operating system update for hardware enablement of the newer hardware, even on older systems. Please refer to the "Compatibility and Feature Matrix" at http://docs.hp.com/hpux/onlinedocs/4076/SG%20SGeRAC%20EMS%20Support%20Matrix_10 3 03.htm DA - 11721 Worldwide — Version 28 — October 23, 2009 Page 18