Transcript
PARAMETER SETTINGS: PAR PAR PAR PAR 168 169 361 362 = = = = 1 1 7 0 BP (ENABLE START AT POWER UP) (FLYING START ENABLE) (RUN) (UNUSED) L1 OL (L1/1) (T1/2) (T1/2) (L2/3) (T2/4) (T2/4) (L3/5) (T3/6) (T3/6) 1L1 2L1 L1R T1U 1T1 1L2 2L2 L2S T2V 1T2 1L3 2L3 L3T T3W 1T3 T1 TO BUS 480V L2 1 T2 MTR 3 PH 60 HZ L3 FDS RS T3 RS 5 GRD 1FU PE 2FU H1 PE HORIZ.GRD.BUS 1 H4 ANALOG IN 1 (V-) H3 H2 H1 FU 0-10V H4 TRANS. X1 X1 2 GRD ANALOG IN 1 (V+) X2 TR 5 (13) OFF HAND RS 1 9 (13) (14) (23) (24) (43) (44) 4-20mA 3 (12) (11) 4 (13) (14) (23) (24) OL 4A TR (A1) (A2) (95) X2 (96) 4 ANALOG IN 2 (CUR+) 1 8 4 EARLY 3 ANALOG IN 2 (CUR-) (14) HAND START HAND STOP AUTO 2 GRD BREAK RS (91) 10 RS 6 7 11 (93) (22) 5 (21) BP (A1) (A2) BYPASS ON BP TO DRIVE CIRCUIT (13) (14) (X2) G HIM LCD DISPLAY (X1) FULL NUMERIC KEYPAD 3 DPI PORT 3 DPI PORT 2 DPI PORT 2 19 RS PLUG 12 1 PLUG 1 X2 FAN (6) (7) 20 DRIVE ON (X2) R (X1) NOTES 1 13 PLUG 1 REMOTE DEVICE 13 DIGITAL OUT 1 - N.O. 2 (1) PLUG REFER TO DRIVE USER MANUAL FOR APPLICATION DATA. 1 12 3 DIGITAL OUT 1 COMMON PARAMETER 090 (SPEED REF A SEL) (2) IS PROGRAMMED FOR OPTION 20 (DPI PORT 3, HIM INSTALLED IN DOOR MOUNTED BEZEL). 4 TR 27 (68) (67) PLUG 1 CLOSED WHEN BUL. 194R ROTARY DISCONNECT SWITCH HANDLE IS SET DIGITAL IN 1 (RUN) (3) T.C. NORMALLY OPEN CONTACT IS SHOWN 27 TO "BYPASS" MODE; WIRE TO THE NORMALLY OPEN CONTACT. (PRESET TO 2 SEC.) 5 25 ROTARY SWITCH (RS) DETERMINES DIGITAL IN COMMON OPERATING MODE FOR THIS UNIT, EITHER BYPASS OR DRIVE. DIAGRAM SHOWS BYPASS MODE. HAND-OFF-AUTO SEL SW DETERMINES BLU WIRE CONTROL & SPEED SOURCE. 26 FROM BYPASS CIRCUIT HAND OPERATION: 24V COMMON 5 FUNCTIONAL FOR BYPASS OR DRIVE MODE. OFF HAND (53) CONTROL IS VIA THE "HAND START" & "HAND STOP" PB'S. AUTO 30 (54) PLUG 1 SPEED REF IS PARAMETER 090 (SPEED REF A SEL), FACTORY SET FOR HIM 30 DIGITAL IN 4 (SPEED SEL 1) (9) MODULE AS DESCRIBED IN NOTE 3, ABOVE. AUTO OPERATION: 24 PLUG FUNCTIONAL ONLY FOR DRIVE MODE. 1 CONTROL IS VIA A CUSTOMER SUPPLIED 24 CONTACT CLOSURE BETWEEN TERMINALS +24V DC 8 AND 4. (5) SPEED REF IS PARAMETER 093 (SPEED REF B SEL), FACTORY SET FOR OPTION 2, (ANALOG INPUT 2). LEGEND TERMINAL LOCATED IN BYPASS UNIT TERMINAL LOCATED IN DRIVE UNIT PIN LOCATED ON CONNECTOR IN DRIVE UNIT 2 POWER TERMINAL LOCATED ON DRIVE 5 POWERFLEX 700 ADJUSTABLE FREQUENCY AC MOTOR DRIVE W/BYPASS W/ 24V DC INTERFACE X X 2 2 1 2 3 4 5 6 7 8 1 1 2 2 3 T T T 2 3 4 7 0 1 2 3 G R TB REVISION RELEASE THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION. MODIFICATIONS TO THIS DRAWING MAY NOT BE MADE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION. PORTIONS OF THIS DRAWING, HOWEVER, CAN BE COPIED AND INCLUDED IN OTHER NON-ROCKWELL AUTOMATION DRAWINGS. REFER. BOOK 1-6-05 A-B ORDER NO. UTURE0-TODD SAUVE BUL. 2164R AC DRIVE W/ BYPASS REFERENCES D 1 BYPASS UNIT CONTROL TERMINAL LOCATED ON DRIVE 8-11.0 AMP NEMA 1 DR. DATE CHKD. DATE APPD. DATE SHEET DWG. SIZE D 1 OF 1 9267WD001 P.C.P./E.S.B. AutoCAD