Transcript
Application description Tools Converting Library Graphic representation of the block Copyright Siemens AG 2015 All rights reserved Manual_Converting_Library_V2.0.0_2015-08-06.doc FBRFG REAL x error REAL nominalValue REAL upperLimit y REAL REAL lowerLimit ya REAL REAL setValue setpointReached BOOL REAL rampUpTime upperLimitReached BOOL REAL rampDownTime lowerLimitReached BOOL BOOL set BOOL followUp BOOL increase BOOL decrease eTaskNameType taskMode errorID BOOL DWORD Block parameters Input parameters Name Data type Initial value Description x REAL 0.0 [ - ] Input quantity nominalValue REAL 1.0 [ - ] Normalization value upperLimit REAL 0.0 [ - ] Upper limit value lowerLimit REAL 0.0 [ - ] Lower limit value setValue REAL 0.0 [ - ] Setting value rampUpTime REAL 0.0 [ ms ] Ramp-up time [ cycle time – MaxTU] rampDownTime REAL 0.0 [ ms ] Braking time constant [ cycle time – MaxTD] set BOOL FALSE FALSE: A setting value is not accepted/transferred TRUE: A setting value is accepted/transferred followup BOOL FALSE FALSE: Normal sequence TRUE: Output is set the same as the input Version 2.0.0 2015-08-06 25/143