“Rethinking sensing technology”
Document version : 1.5
Document Type : Technical note
Data acquisition modes available
on the BeanDevice®
Low Duty Cycle Data Acquisition Mode
∆t1
∆t2
Δt
Δt
Δt
Sleep
Sleep
Sleep
∆t3
∆t4
t
In Low Duty cycle data acquisition (LDCDA), the BeanDevice® operates as follows:
 Step 1 : A Data acquisition is performed;
 Step 2: If Datalogger feature is enabled: the data acquisition is registered on the
Beandevice® data logger ;
 Step 3: If “Wireless transmission” option is enabled: the data acquisition is transmitted to
the BeanGateway® ;
 Step 4: A Network diagnostic is performed and transmitted to the BeanGateway®
(depending on the diagnostic cycle defined by the user)
 Step 5 : The BeanDevice® goes to sleep (if “sleep” or “sleep with network listening” power
mode is enabled)
Go to the LDCDA Flowchart diagram section for a flowchart representation of the LDCDA
data acquisition mode.