User manual DC/DC-Module PM3Kxxx Operation a) ZK VS DC Source Load DC Application possible sources: DC-power line, PFC possible load/charge: arbitrary Parameter mod_opmode: 0 vs_imax: 0 bzw. >0 vs_imin: - desired current limit zk_usoll: Desired value DC-Link voltage, smaller than the minimum occurring ZK voltage vs_usoll: desired output voltage In this particular application case, the module functions as a typical electric power supply: it maintains the output voltage constant in the desired value, vs_usoll, and limits the current, during overcharge, to vs_imin. (Attention: vs_imin is negative, because the direction of current is defined into the module). The parameter vs_imax must stay at 0, so that no current can flow into the module. In some cases hereby it can occur that the voltage runs high, as a result of offset errors, if no load is connected. It is recommended in this case to allocate a small positive value of approximately 1…3A to vs_imax, so as to be able to maintain the voltage on the desired value. The parameter zk_usoll is the desired value for the DC-Link voltage. If this falls below this value, the ZK - voltage regulator tries to maintain the value. It does this by preventing power to flow from the DC-Link into the VS- side. This means the output voltage disintegrates or breaks down during overcharge. If this method is undesired, but instead that a hard disconnection should take place during overcharge, zk_usoll should be set to the possible minimum value 3500 (equivalent to 350V). If break down or disintegration of the DC-Link voltage now occurs, the regulator can not intervene and the module switches off due to low DC-Link voltage. 40 Flexiva automation & Robotik GmbH Weißbacher Straße 3 D – 09439 Amtsberg