Download V400-R2 Series Ultra Small Multi-code Reader User`s Manual

Transcript
Section 2
Introduction Procedure
Reading angle performance
 Pitch angle (α)
In the following conditions, readable up to α = 50° on either side.
• Code:
Resolution = 0.330 mm, UPC (12 digits), PCS = 0.9
• Reading distance:
65 mm (V400-R2CF65) or 125 mm (V400-R2CF125) from the
case end
Section 2 Preliminary Examination
• Installation condition: Skew angle β = 15°, tilt angle γ = 0°, curvature R = ∞
 Skew angle (β)
In the following conditions, readable up to β = +/-50°.
• Code:
Resolution = 0.330 mm, UPC (12 digits), PCS = 0.9
• Reading distance:
65 mm (V400-R2CF65) or 125 mm (V400-R2CF125) from the
case end
• Installation condition: Pitch angle α = 0°, tilt angle γ = 0°, curvature R = ∞
Reading performance for bar codes on a highly gloss surface such as glossy paper or a card case
may be impaired because reflected illumination LED light or room illumination light enters the
reading window.
If reflected illumination LED light is the culprit, reading performance can be improved by providing
an angle of about 15° in the skew direction.
V400-R2 series
User’s Manual
29