SESAM Prefem Program version 7.1 01-JUN-2003 5-191 PROPERTY SECTION section-name BAR ... BAR hz bb bt sfy sfz PURPOSE: The command defines a bar cross section. 5.45 Figure 5.45 Bar section PARAMETERS: hz Height bb Width at bottom bt Width at top sfy sfz Factors modifying the shear areas calculated by the program. The modified shear areas are (see the PRINT SECTION command for an explanation of the parameters): SHARYmodified = SHARYprogram ⋅ sfy SHARZmodified = SHARZprogram ⋅ sfz