Transcript
[SETTINGS] (SEt-) menu rEFSEt- Code drC- JPF Description Adjustment range Factory setting • [Skip Frequency] 0 to 500 Hz 0 Hz I-0- Helps to prevent prolonged operation at a frequency range of ± 1 Hz around [Skip Frequency] (JPF). This function helps to prevent a critical speed which leads to resonance. Setting the function to 0 renders it inactive. CtLFUn- JF2 • [Skip Frequency 2] 1 to 500 Hz 0 Hz FLt- Helps to prevent prolonged operation at a frequency range of ± 1 Hz around [Skip Frequency 2] (JF2). This function helps to prevent a critical speed which leads to resonance. Setting the function to 0 renders it inactive. COM- JGF SUP- • [Jog frequency] • [PID prop. gain] • [PID integral gain] • [PID fbk scale factor] nO YES 0.01 to 100/s 1 0.1 to 100 1 Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77. For adapting the process. * PIC 1 Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77. It provides static precision when PI feedback is changing slowly. * FbS 0.01 to 100 Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77. It provides dynamic performance when PI feedback is changing quickly. * rIG 10 Hz Parameter can be accessed if [JOG] (JOG) is not set to [No] (nO), page 72. * rPG 0 to 10 Hz [No] (nO) • [PID correct. reverse] - Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77. [No] (nO): Normal [Yes] (YES): Reverse * rP2 * rP3 * rP4 * SP2 * * 34 • [Preset ref. PID 2] 0 to 100% 30% Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77, and if [2 preset PID ref.] (Pr2), page 77, has been enabled by the input selection. • [Preset ref. PID 3] 0 to 100% 60% Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77, and if [4 preset PID ref.] (Pr4), page 78, has been enabled by the input selection. • [Preset ref. PID 4] 0 to 100% 90% Parameter is only visible if [PID feedback ass.] (PIF) is not set to [No] (nO), page 77, and if [4 preset PID ref.] (Pr4), page 78, has been enabled by the input selection. • [Preset speed 2] 0 to 500 Hz 10 Hz See page 70. These parameters only appear if the corresponding function has been selected in another menu. When the parameters can also be accessed and set from within the configuration menu for the corresponding function, their description is detailed in these menus, on the pages indicated, to aid programming.