Download Chapter 1
Transcript
4-14 Programming Motor Protection While the Basic Set Up group allows the user to get started with a minimum number of parameters to modify, the Motor Protection group allows full access to the SMC-Flex controller's powerful parameter set. Following is a listing of the additional setup parameters provided. Note: The majority of parameters have a Fault and an Alarm setting. Parameter Overload Allows the user to select the operation of the overload. Underload Determines the trip level as a percentage of the motor’s FLA, and the delay period. Undervoltage Determines the trip level as a percentage of line voltage and delay period. Overvoltage Determines the trip level as a percentage of line voltage and delay period. Unbalance Allows the user to set the current unbalance trip level and delay period. Jam Determines the trip level as a percentage of motor full load current and delay period. Stall Allows the user to set the stall delay time. Ground Fault Allows the user to enable the ground fault level in amps, delay time and inhibit time. A separate core balance current transformer is required. PTC Allows the user to connect a PTC to the SMC and enable a fault when it becomes active. Phase Reversal Determines the proper orientation of line connections to the SMC. If Enabled and phases are out of sequence, a fault will be indicated. Restarts Allows the user to determine the maximum number of restarts per hour the unit can experience, and delay time between consecutive starts. Option Trip Class, Service Factor, Motor FLC, Overload Reset, Overload Alarm Level Underload Fault Level, Underload Fault Delay, Underload Alarm Level, Underload Alarm Delay Undervoltage Fault Level, Undervoltage Fault Delay, Undervoltage Alarm Level, Undervoltage Alarm Delay Overvoltage Fault Level, Overvoltage Fault Delay, Overvoltage Alarm Level, Overvoltage Alarm Delay Unbalance Fault Level, Unbalance Fault Delay, Unbalance Alarm Level, Unbalance Alarm Delay Jam Fault Level, Jam Fault Delay, Jam Alarm Level, Jam Alarm Delay Stall Delay Ground Fault Enable, Ground Fault Level, Ground Fault Delay, Ground Fault Inhibit Time, Ground Fault Alarm Enable, Ground Fault Alarm Level, Ground Fault Alarm Delay PTC Enable Phase Reversal Restarts Per Hour, Restart Attempts, Restart Delay The delay time must be set to a value greater than zero when Undervoltage, Overvoltage and Unbalance are enabled. For Jam and Underload detection to function, the Motor FLC must be programmed in the Motor Protection group. See page 4-16. See details in Ground Fault on page 1-12. See details in Thermistor/PTC Protection on page 1-13. 1560E-UM051A-EN-P – September 2005