Download Federico Milano

Transcript
Power Flow &
Initial State Variables
t = t0
Evaluate initial
time step ∆t
i=0
i=i+1
no
yes
i > imax
Reduce ∆t
∆t < ∆tmin
yes
Evaluate
END
Singularity
likely
disturbance
Evaluate system
equations & Jacobians
Compute
Integration
∆x and ∆y
method
no
no
|∆xi |, |∆y i | < ǫ
yes
Output
Update x & y
Recompute
∆t
no
yes
t + ∆t ≥ tf
END
Figure 8.1: Time domain integration block diagram.