LC100 Instruction manual 4/6 Parameters D-32 4/12 Door Passenger passing time after cabin call Type D 0-25s Passenger passing time after new cabin call while in station. By giving new cabin command passenger passing time is set by parameter. D-33 Door deceleration time 0-25s Parameter is used to activate input function FO-42 (for A door) or FO-46 (for B door) with doors with no before end-switches. Parameter estimates the time of opening or closing the door and activates a low speed depending on the parameter. D-34 Door reversing time 0-2,5s Parameter is time with no active commands for open and close door while reversing. D-35 Door resistors time 0-25s The parameter is the time of the resistors to reduce the mechanical strain of the door if resistor function is in use FO-43 for A-side door, FO-47 for B-side door. D-36 Door locking time 0-2,5s After door lock acivating, system filtrates input for stabilizing door lock contact and starts traveling after filter set by parameter. The parameter is used to prevent safety circuit break after start command. 79