Download datasheet

Transcript
 NEV
VO+12
200S SSERIESS ‐ Modular ‐ User Configgurable ‐ 1200 Watts of Power
NEVO+1200S sseries are moduular and user cconfigurable poower supplies ooffering unriva
The lled performan
nce and flexibillity. Deliveringg up to 0 watts from a a 1.2kg 6” x 6” x 1U package, the NEVO is the ultimate p
power solution for applications where size and weight arre vital 1200
ors. Each systeem consists of aan input modulle with eight slots where any combination o
of outputs can bbe fitted to creeate a power soolution facto
nd
with
h up to sixteen isolated outpu
uts. The series carry full UL60
0950 2 Editio
on safety appro
ovals and comp
ply with EN61000‐3, EN61000
0‐4 and 50022‐B EMC sstandards. EN55
N FEATURES: MAI
 



1200 watt outp
1
put at 120VAC 6
6” x 6” x 1U foo
otprint H
High power den
nsity (21W/in3) )
nd
E
EN60950 2
Ed
dition P
Primary Side Re
emote On/Off 









High efficien
ncy – up to 89%
% Only 1.2kg –– 100W/kg I2C control o
option
Remote current/voltage programming
Accurate current sharing Current output siignal 2x 5V 1A bias sup
pply Ro
oHS compliant Fie
eld configurable
e Tw
wo year warranty SYSTEM
M SPECIFICATIO
ONS
INSTALLATION I
INP
PUT ELECTRICALL Param
meter Details AC Input Voltage e is 100V to 240V Nominal range
Contact factorry for 400Hz operation. Standard See graphs for deratings 1200W output at 120Vrms input 265Vrms (cold
d start) 5x20 Fast acting
AC Input Frequency S i g n a l s DC Input Voltage Powe
er Rating Inputt Current Inrush
h Current Fusing Inputt Current Limit Efficie
ency Idle P
Power Idle P
Power Stand
dby Power Powe
er Factor Holdu
up UVLO
O Over temperature Reliab
bility Output Bias voltage Output Bias current Power Good voltage Power Good current Inhibit voltage Inhibit current Global inhibit voltage Global inhibit current AC_OK voltagee AC_OK current AC_OK warningg Primary Bias voltage Primary Bias current Primary Remotee On/Off Min 85
47 17
78
115
4.8 0 8 0 14
86 46
32
2.5
0.99
20
5 10 2
0.2 3 Units
264
Vrmss
63 Hz
370
1200
Vdc
Wattts
Amps
Amps
Amps
Amps
%
Wattts
Wattts
Wattts
40
12.5
PNP open collector with internal 10k pull down
n resistor Max 12
Hiccup type ccurrent limit 10k ohm input impedance 50/
60 120
See graphs All outputs fittted and enabled All outputs fittted and Disabled Latched off state, 120Vrms 1200W output at 120Vrms input Turn on only Internally mon
nitored. Latching 40°C 80% load
d Two isolated B
Bias Outputs available Typ
89 0.99
21
84
125
2
mS
Vrmss
°C
FPMH
H
5.2 V
1 A
15 V
20 mA
15
1.5 V
mA
15 V
5k ohm input impedance 0.6 3 mA
High output Low output See user manu
ual for exceptions 4.7 0
‐10 5
5.2 0.1
10 V
V
mA
mS
Medically Isolated 4.8 5.2 V
5 Hiccup type cu
urrent limit 0.5 A
Negative Edgee Triggered, Refer to User Manual 5 V
Vox Power Ltd. Unitt 9 Robinhood Business Park Robinhood Road, Balllymount, Dublin 22 Rep.. of Ireland Tel: +353 1 426 49300 b: ww.vox‐powerr.com Web
Parameterr Deta
ails Equipment class I Installation
n category
II
Pollution d
degree 2 Material ggroup IIIb Parameter Detailss Flammaability rating IP Ratingg ROHS Compliaance
94V‐2
IP10
95/EC 2002/9
Indoorr use only RELIABILITY Componen
nt Details FAN
INPUT
d (2 Fans per unit) Mag Lev Std
Excluding FA
AN See individu
ual output datasheets OUTPUT Min Warranty
Max Units 3.8
2
FPMH
FPMH
1 FPMH 2
Years
SAFETY Parameterr Isolation Voltage Isolation Clearance
Isolation Creepage
Leakage Cu
urrent
Details Min Input to Ou
utput Input to Ch
hassis Output to Chassis Output to Output Primary to Secondary (Reinforced) Primary to Chassis (Basic) Primary to Secondary (Reinforced) Primary to Chassis (Basic) 265Vac, 63
3Hz, 25°C Weight Mounting
Distributed By: Vac Vac Vdc
Vdc
7 mm mm
12 mm 4
MECHANICAL Size Units 2.5
Parameterr Max 4000
1500
250
250
Details 154.5mm (L)) x 152.4 mm (W) x 41.0mm (see diagram
m for tolerance detaails) 720 gram +6
60 gram per output module Bottom (see diagram for detailss) 1500
mm
uA
DATASHEET
D A T A S H E E T N
NEVO+
+1200
0S SER
RIES
Max U
Units Temperature Humidity Altitude Air Pressure Relative, non‐con
ndensing Full power De‐rate input and
d outputs at 2.5%/°C Relative, non‐con
ndensing ‐40 5 ‐200 54 ‐20 +85
95
5000 106
50
°C
%
m kPa
°C
50 70 °C 5 ‐200 78 95 3000
106
42
61 % m
kPa
dBA
d
dBA d
Humidity Altitude Air Pressure Noise Level Shock Vibration Unit at idle Unit at full powerr,25°C Measured 1m fro
om fan intake 3000 bumps at 10
0G (16ms) half sine wave 1.5G 10 to 200Hz sine wave, 20G forr 15min in 3 axes random vibration
n Emissions
Emissions Min Temperature O p e r a t i o n EMC
E
Details AGENCY APPROVALS
A
Sta
andard Deetails Stand
dard Radiated electric field
Conducted em
missions
Harmonic Disttortion Flicker & Flucttuation
EN55
5011, EN55022, FCC
C EN55
5011, EN55022, FCC
C EN61
1000‐3‐2 EN61
1000‐3‐3 1000‐4‐2 EN61
(15kV
V air, 8kV contact) EN61
1000‐4‐3 (10V/m) EN61
1000‐4‐4 (4kV) EN61
1000‐4‐5 (1kV L‐N, 2
2kV L‐E)
EN61
1000‐4‐6 (10V) Radiated RFI
Fast Transientt burst
Input line surgges
Conducted RFFI
Power Freq. M
Magnetic Field
Voltage Dips
Le
evel A (See Note)
B
Com
mpliant Com
mpliant
4 3 4
3
4
EN61
1000‐4‐8 (10A/m) 3 EN61
1000‐4‐11 (EN55024
4) Com
mpliant
Note: To meet Class B radiated emissio
N
ons the end user sho
ould add ferrites to I/P and O/P cables. Consult Vox Power for details. File ULL60950‐1 2nd editio
on, revised Decemb
ber 19
9, 2011 IEC 60950‐1:2005 (2n
nd Edition); Am 1:20
009 UL6
60950‐1 Parameter Electrostatic d
discharge Immunity
Immunity S t o r a g e ENVIRON
NMENTAL
Parameter IEC
C/EN60950‐1 CSA
A‐C22.2 No. 2n
nd edition 609
950‐1A‐07 CE MARK LV
VD 73/23/EEC CB certificate and repo
ort available on req
quest UL: E31648
86 Typical Line Efficiency (Pmax
x)
0.90
0.89
0.88
0.87
Effi i
Efficiency
Efficiency
Typical Load Effficiency (220Vrm
ms)
0.92
0.90
0.88
0.86
0.84
0.82
0.80
0.78
0.76
0.74
0.72
0.70
0.68
0.66
200
3
300
400
500
600
700
800
900
1000
1100
0.85
0.84
0.83
OP1
OP2
OP3
OP4
100
0.86
OP1
OP2
OP3
OP4
4
0.82
0.81
0.80
1200
80
1
120 130 140 150 160 170 180 190 20
00 210 220 230 240 250
2
260
90 100 110
Output power (W)
put Voltage(Vrms)
Inp
Tempera
ature Derating
1400
1200
1200
1000
1000
Output Power (W)
p Power (W)
( )
Output
Line De
erating
1400
800
Derate at 10
0W per Volt below 120Vrrms
600
No Derrating for DC operation
400
200
800
Derate at
a 30W per degree celciu
us above 50 degree celcius
600
400
200
0
80
100
120
140
16
60
180
Input Vo
oltage (RMS)
Vox Power Ltd. Unitt 9 Robinhood Business Park Robinhood Road, Balllymount, Dublin 22 Rep.. of Ireland Tel: +353 1 426 49300 b: ww.vox‐powerr.com Web
200
220
240
0
26
60
-20
-10
0
10
20
30
40
0
Ambient Temperature
T
(Celcius)
Distributed By: 50
60
70
DATASHEET
D A T A S H E E T N
NEVO+
+1200
0S SER
RIES
MECHANICAL DIMENSIONS AND MOUNTING SCREW
WS SCREWS LOCA
ATION DETAILS PENETRA
ATION TTIGHTENING MOU
UNTING M4 x 4 4mm max, inclu
uding chassis 0.75 NM OUTPUT MODULES M3 x 5, C
Countersink Posi, 16
6 Places Defined byy screw 0.75 NM CHASSIS LID A
AND FACEPLATE M3 x 5, C
Countersink Posi, 11
1 Places Defined byy screw 0.75 NM M4 (4X) 4mm depth max
Vox Power Ltd. Unitt 9 Robinhood Business Park Robinhood Road, Balllymount, Dublin 22 Rep.. of Ireland Tel: +353 1 426 49300 b: ww.vox‐powerr.com Web
Distributed By: D A T A S H E E T NEVO
N O+1200
0S SER
RIES
Circuit 1 2 3 Circuit 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 REF J1 CONNECTOR
RS
PINOUTS J1 Detailss v
1
6
Livve Earrth Neeutral J2a/b Detailss Pow
wer Good Inh
hibit Pow
wer Good Inh
hibit Pow
wer Good Inh
hibit Pow
wer Good Inh
hibit Glo
obal Inhibit AC
C OK +5V
V 1A Bias Supply CO
OM J6 Common +5V
V 500mA Bias Shu
ut Down Reserved Reserved Reserved J6
Slot A and E Slot B and F Slot C and G Slot D and H E
N
L
J1
J2a
J2b
2
12
1
11
J1
MANUFFACTURER
DEETAILS MA
AINS INPUT: 3 Pin, B
Barrier, 6‐32 Steel SScrews, 0.8 NM or 7
7IN LB Torque Cable 14‐18AWG, 300
0V, 16A, 105°C, use appropriately rated
d fork or ring termin
nal. GLOBAL SIGNALS: 12 Pin, 2mm, with Fricction Lock, 24‐30 AW
WG INP
PUT BIAS: OUTPUT SIGNALS: 6 Pin, 1.25mm, with Friction lock, 28‐32 AWG J2a/b J6 Notes d for any connector parts. 1. Direct equivalents may be used
2. All cables mu
ust be rated 105°C min, equivalent to UL1015
HOU
USING TERMINAL
MOLEX MOLEX MOLEX 511101260 510210600 503948051
1 500588000
0 P
PART
NUMBERING SYSTEM
NEVO Power S
Series
Leakage Currrent
NEV
VO+1200
S
-
1
1
2
2
3
3
4
4
-
0
0
0
Factory Use
e
Standard
USE '0' for unused
d slots.
Blanking plates will
w be
inserted at facto
ory.
Slot A - Outpu
ut #
Slot H - Outputt #
Slot B - Outpu
ut #
Slot G - Output #
Slot C - Outpu
ut #
Slot F - Outputt #
Slot D - Outpu
ut #
Slot E - Outputt #
Contact your Distrib
butor or Vox Power fo
or special configuratio
on requirements. The
e factory may allocatte a 3 or 4 digit suffix
x to identify such requ
uirement.
Vox Powe
er Ltd. reserves the right to change or improve any part of the specification, electrical orr mechanical design or manufacturing processs without notice. Pleaase consult your local d
distributor or contact V
Vox Power to ensure that you have the latest specification before using your product. Forr other information relating to the use of thee product please refer tto the latest NEVO useer manual. Vox Power reserves the right to m
make changes notice to any of its prod
ducts. Vox Power doess not assume any liabiliity arising out of the usse or application of anyy of its products and off any information to th
he maximum extent peermitted by law. No liceense, express without n
or implied
d, by estoppel or otherrwise, to any intellectu
ual property rights is grranted by this document or by any conduct o
of Vox Power. VOX POW
WER DISCLAIMS ALL W
WARRANTIES AND REPR
RESENTATIONS. IN PAR
RTICULAR ALL OTHER W
WARRANTIES, CONDITIO
ON OR TERMS RELATIN
NG TO SUITABILITY, FITTNESS FOR PURPOSE, M
MECHANTABILITY OR C
CONDITION OF THE PR
RODUCTS AND WHETHER EXPRESS OR IMPLIEED BY STATURE OR CO
OMMON LAW OR OTHER
RWISE ARE EXCLUDED.. C6034 rev 01 Document DOC
D A T A S H E E T NEVO SERIES
OP1 Patents pending
OUTPUT 1 SPECIFICATIONS
Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise Transient response Turn on rise time Turn on overshoot Turn on delay Current share accuracy Open sense offset Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Over voltage protection Over Temperature protection Sense cable protection Power Good threshold Current output signal Current limit control Remote voltage control Bias supply Reliability Warranty Wire Size Weight Size ‐0.5 Typ 5 Max 7.5 25 125 Units V A Watts 187.5 Watts OUTPUT 1 POWER PROFILE
10
OVP
9
8
7
Peak power
6
5
4
0.5 50 0.1 0.2 0 % V/turn mV %Vnom %Vnom Watts 0.02 %/°C 0.545 ‐50 ‐0.1 ‐0.2 125
W
3
OCP
See graph, < 5 seconds 50% duty cycle Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 1.5 Volts
Peak output power Details See table CONTINIOUS POWER
2
1
HICCUP
0
0
5
10
15
20
25
30
Amps
20MHz BW, pk‐pk 25% to 75% load transient at 1A/us Recovery to within 10% of Vset Monotonic 10% to 90% AC to PG En to PG Open sense, voltage offset due to bias currents ‐0.02 1 %Vnom 1 V 100 uS 3.5 0.1 750 20 5 mS %Vset mS mS %Imax 2 %Vnom 1.5 600 15 Each terminal % of rated current 105 % of rated current ‐6 6 250 V V 125 %rated 0 %rated Period Duty cycle Voltage threshold (Measured at sense terminals) 125 3 1 mS % V Latching Internally monitored. Latching Positive Negative Low threshold only ISIG=0.6+IOUT/(IRTD*1.25) ILMT = (VCTRL‐0.6)*IRTD*1.25 VOUT=VSET((1.8‐VCTRL)/0.6) 10mA max 40°C 80% load 60mm x 35mm x 17mm 115 9.5 ‐1 125 2 1 0 4.5 12 5 °C 110 110 V V %Vset %Irated %Irated 300 %Vset 90 0 0 V 5.2 1 2 10 60 V FPMH Years AWG Grams RIPPLE
0.02
0.015
0.01
0.005
Volts
Parameter Output voltage range Rated current Average output power Manual trim range
0
-0.005
-0.01
-0.015
-0.02
0
2
4
6
8
10
12
14
16
18
20
uS
Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6002 rev 02 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511 Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES
OP2 Patents pending
OUTPUT 2 SPECIFICATIONS
Transient response Turn on rise time Turn on overshoot Turn on delay Current share accuracy Open sense offset Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Over voltage protection Over Temperature protection Sense cable protection Units V A Watts 225 Watts 0.5 100 0.1 0.2 0 % V/turn mV %Vnom %Vnom Watts 0.02 %/°C 0.954 ‐100 ‐0.1 ‐0.2 OUTPUT 2 POWER PROFILE
20
OVP
18
16
14
12
10
Peak power
8
6
150
W
CONTINIOUS POWER
OCP
Max 15 15 150 Volts
‐0.5 Typ 12 4
2
HICCUP
0
0
2
4
6
8
10
12
14
16
18
Amps
20MHz BW, pk‐pk 25% to 75% load transient at 0.5A/uS Recovery to within 10% of Vset Monotonic 10% to 90% AC to PG En to PG Open sense, voltage offset due to bias currents ‐0.02 %Vnom 1.5 600 15 1.5 V 100 uS 3.5 0.1 750 20 5 mS %Vset mS mS %Imax 2 %Vnom Each terminal % of rated current 1 12.5 250 105 125 V V %rated 0.75
% of rated current Period Duty cycle Voltage threshold (Measured at sense terminals) ‐6 125 3 0 TRANSIENT RESPONSE
1.5
%rated mS % 20
0
-0.75
15
-1.5
10
-2.25
-3
2 5
V -3.75
-4.5
Latching Internally monitored. Latching Positive Negative Low threshold only ISIG=0.6+IOUT/(IRTD*1.25) ILMT = (VCTRL‐0.6)*IRTD*1.25 115 ‐1 18 125 2 1 Amps
Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise See graph, < 5 seconds 50% duty cycle Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 4.5 Volts
Peak output power Details See table V -0.75
-0.55
-0.35
-0.15
0
0.25
0.05
mS
°C V V %Vset %Irated %Irated Power Good threshold 90 Current output signal 0 110 Current limit control 0 110 Remote voltage VOUT=VSET((1.8‐VCTRL)/0.6) 0 300 %Vset control Bias supply 10mA max 4.5 5 5.2 V Reliability 40°C 80% load 1 FPMH Warranty 2 Years Wire Size 16 14 10 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. RIPPLE
0.04
0.03
0.02
0.01
Volts
Parameter Output voltage range Rated current Average output power Manual trim range
0
-0.01
-0.02
-0.03
-0.04
-10
-8
-6
-4
-2
0
2
4
6
8
10
uS
Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6003 rev 02 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511 Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES
OP3 Patents pending
OUTPUT 3 SPECIFICATIONS
Turn on rise time Turn on overshoot Turn on delay Current share accuracy Open sense offset Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Over voltage protection Over Temperature protection Sense cable protection 20MHz BW, pk‐pk 25% to 75% load transient at 0.25A/uS Recovery to within 10% of Vset Monotonic 10% to 90% AC to PG En to PG Open sense, voltage offset due to bias currents 225 Watts 0.5 % V/turn mV %Vnom %Vnom Watts %/°C
1.9 ‐150 ‐0.1 ‐0.2 ‐0.02 150 0.1 0.2 0 0.02 Period Duty cycle Voltage threshold (Measured at sense terminals) OVP
35
30
25
20
Peak power
15
150
W
CONTINIOUS POWER
10
5
HICCUP
0
0
1
2
3
4
5
6
7
8
9
Amps
1 %Vnom 1.5 3 V 100 uS 3.5 0.1 750 20 5 mS %Vset mS mS %Imax 600 15 2 %Vnom 105 25 250 V V 125 %rated TRANSIENT RESPONSE
% of rated current OUTPUT 3 POWER PROFILE
40
Each terminal % of rated current Units V A Watts OCP
Max 30 7.5 150 ‐6 125 3 3.5 0 %rated 12
3
1.5
10
0
8
-1.5
mS % 6
-3
-4.5
V Amps
Transient response ‐0.5 Typ 24 Volts
Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise See graph, < 5 seconds 50% duty cycle Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 9 Volts
Peak output power Details See table 4
-6
2
-7.5
Latching Internally monitored. Latching Positive Negative Low threshold only ISIG=0.6+IOUT/(IRTD*1.25) ILMT = (VCTRL‐0.6)*IRTD*1.25 115 ‐1 36 125 2 1 V -9
-0.75
-0.55
-0.35
-0.15
0
0.25
0.05
mS
°C V V %Vset %Irated %Irated Power Good threshold 90 Current output signal 0 110 Current limit control 0 110 Remote voltage VOUT=VSET((1.8‐VCTRL)/0.6) 0 300 %Vset control Bias supply 10mA max 4.5 5 5.2 V Reliability 40°C 80% load 1 FPMH Warranty 2 Years Wire Size 20 18 10 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. RIPPLE
0.05
0.04
0.03
0.02
Volts
Parameter Output voltage range Rated current Average output power Manual trim range
0.01
0
-0.01
-0.02
-0.03
-0.04
-0.05
-10
-8
-6
-4
-2
0
2
4
6
8
10
uS
Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6004 rev 02 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511 Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES
OP4 Patents pending
OUTPUT 4 SPECIFICATIONS
Parameter Output voltage range Rated current Average output power Peak output power Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise Transient response Turn on rise time Turn on overshoot Turn on delay Current share accuracy Open sense offset Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Over voltage protection Over Temperature protection Sense cable protection Details See table See graph, < 5 seconds 50% duty cycle Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals 20MHz BW, pk‐pk 25% to 75% load transient at 0.25A/uS Recovery to within 10% of Vset Monotonic 10% to 90% AC to PG En to PG Open sense, voltage offset due to bias currents Min 18 ‐0.5 Typ 48 Max 58 3.75 150 Units V A Watts 225 Watts 0.5 % V/turn mV %Vnom %Vnom Watts %/°C
3.6 ‐300 ‐0.1 ‐0.2 ‐0.02 300 0.1 0.2 0 0.02 1 %Vnom 3 V 100 uS 3.5 0.1 750 20 5 mS %Vset mS mS %Imax 2 %Vnom 1.5 600 15 Each terminal % of rated current 105 % of rated current ‐6 50 250 V
V 125 %rated 0 %rated Period Duty cycle Voltage threshold (Measured at sense terminals) 125 3 3.5 mS % V Latching Internally monitored. Latching Positive Negative Low threshold only ISIG=0.6+IOUT/(IRTD*1.25) ILMT = (VCTRL‐0.6)*IRTD*1.25 115 ‐3 66 125 3 2 V °C V
V %Vset %Irated %Irated Power Good threshold 90 Current output signal 0 110 Current limit control 0 110 Remote voltage VOUT=VSET((1.8‐VCTRL)/0.6) 0 300 %Vset control Bias supply 10mA max 4.5 5 5.2 V Reliability 40°C 80% load 1 FPMH Warranty 2 Years Wire Size 20 18 10 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6006 rev 01 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511 Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES
OP5 OUTPUT 5 SPECIFICATIONS
Parameter Output voltage range Rated current Rated power Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise Transient response (Vset = 5V) Turn on rise time Turn on overshoot Turn on delay Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Details Each channel Each channel Each channel Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 5 Typ 12 60 ‐1 ‐50 ‐0.1 ‐0.2 1.5 AC to PG En to PG 600 30 Each terminal Hiccup mode only Units V A Watts % V/turn 50 mV 0.1 %Vnom 0.2 %Vnom 0 0.02 2 Watts %/°C %Vset 1 V 100 uS 3.5 0.1 750 40 12 250 130 mS %Vset mS mS V V %rated mS % 0.9 ‐0.02 20MHz BW, pk‐pk 25% to 75% load transient at 1A/uS Recovery to within 10% of Vset Monotonic 10% to 90% Max 15 5 75 1 105 None 30 1 Period Duty cycle Over voltage protection Latching 20 V Over Temperature Internally monitored. 115 125 °C protection Latching Power Good thresholds High and Low window 68 120 %Vset Reliability 25°C, 100% load, Telcordia 1 FPMH Warranty 2 Years Wire Size 20 18 10 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. 10.60
TOP Adjust
BOTTOM Adjust
J5
Dimension with reference to edge of
chassis and centre of connector when in
Slot A—Slot pitch 18.30mm J5
TOP—Positive Output
16.50
TOP—Negative Output
BOTTOM—Negative Output
Dimension with reference to top of
chassis and centre of connector.
BOTTOM—Positive Output
1
J5
5
REF.
DETAILS
MANUFACTURER
HOUSING
Circuit Details 1 Top + Sense 2 Top – Sense 3 Open 4 Bottom + Sense 5 Bottom ‐Sense TERMINAL
J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 20‐24 AWG MOLEX 430250400 430300001 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 105°C min, equivalent to UL1015 Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6014 rev 03 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511, Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES
OP6 OUTPUT 6 SPECIFICATIONS
Parameter Output voltage range Rated current Rated power Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise Transient response (Vset = 5V) Turn on rise time Turn on overshoot Turn on delay Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Details Each channel Each channel Each channel Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 1.8 Typ 3.3 16.5 ‐1 ‐50 ‐0.1 ‐0.2 1.5 AC to PG En to PG 600 15 Each terminal Hiccup mode only Units V A Watts % V/turn 50 mV 0.1 %Vnom 0.2 %Vnom 0 0.02 2 Watts %/°C %Vset 0.5 V 100 uS 3.5 0.1 750 20 5 250 130 mS %Vset mS mS V V %rated mS % 0.3 ‐0.02 20MHz BW, pk‐pk 25% to 75% load transient at 1A/uS Recovery to within 10% of Vset Monotonic 10% to 90% Max 5 5 25 1 105 None 30 1 Period Duty cycle Over voltage protection Latching 8 V Over Temperature Internally monitored. 115 125 °C protection Latching Power Good thresholds High and Low window 68 120 %Vset Reliability 25°C, 100% load, Telcordia 1 FPMH Warranty 2 Years Wire Size 24 22 20 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. 10.60
TOP Adjust
BOTTOM Adjust
J5
Dimension with reference to edge of
chassis and centre of connector when in
Slot A—Slot pitch 18.30mm J5
TOP—Positive Output
16.50
TOP—Negative Output
BOTTOM—Negative Output
Dimension with reference to top of
chassis and centre of connector.
BOTTOM—Positive Output
1
J5
5
REF.
DETAILS
MANUFACTURER
HOUSING
Circuit Details 1 Top + Sense 2 Top – Sense 3 Open 4 Bottom + Sense 5 Bottom ‐Sense TERMINAL
J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 20‐24 AWG MOLEX 430250400 430300001 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 105°C min, equivalent to UL1015 Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6012 rev 02 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511, Web: ww.vox‐power.com Distributed By: D A T A S H E E T NEVO SERIES OP7 OUTPUT 7 SPECIFICATIONS
Parameter Output voltage range Rated current Rated power Initial voltage accuracy Manual Voltage Adjust Load Regulation Line Regulation Cross Regulation Minimum Load Temperature coefficient Ripple and Noise Transient response (Vset = 5V) Turn on rise time Turn on overshoot Turn on delay Holdup voltage Isolation to ground Over current protection Reverse current protection Short circuit protection (Hiccup mode) Details Top/Bottom channel Each channel Top/Bottom channel Factory set units 11 turn potentiometer Measured at sense terminals Measured at sense terminals Measured at sense terminals Min 1.8/5 Typ 3.3/12 60/16.5 ‐1 Units V A Watts % V/turn 50 mV 0.1 %Vnom 0.2 %Vnom 0 0.02 2 Watts %/°C %Vset 1/0.5 V 100 uS 3.5 0.1 750 20 12/5 250 130 mS %Vset mS mS V V %rated mS % 0.3/0.9 ‐50 ‐0.1 ‐0.2 ‐0.02 20MHz BW, pk‐pk 25% to 75% load transient at 1A/uS Recovery to within 10% of Vset Monotonic 10% to 90% 1 AC to PG En to PG 600 15 Each terminal Hiccup mode only Max 5/15 5 75/25 1 105 None 30 1 Period Duty cycle Over voltage protection Latching 20/8 V Over Temperature Internally monitored. 115 125 °C protection Latching Power Good thresholds High and Low window 68 120 %Vset Reliability 25°C, 100% load, Telcordia 1 FPMH Warranty 2 Years Wire Size 24 22 20 AWG Weight 60 Grams Size 60mm x 35mm x 17mm Notes: All specifications are believed to be correct at time of publication and are subject to change without notice. 10.60
TOP Adjust
BOTTOM Adjust
J5
Dimension with reference to edge of
chassis and centre of connector when in
Slot A—Slot pitch 18.30mm J5
TOP—Positive Output
16.50
TOP—Negative Output
BOTTOM—Negative Output
Dimension with reference to top of
chassis and centre of connector.
BOTTOM—Positive Output
1
J5
5
REF.
DETAILS
MANUFACTURER
HOUSING
Circuit Details 1 Top + Sense 2 Top – Sense 3 Open 4 Bottom + Sense 5 Bottom ‐Sense TERMINAL
J1 OUTPUT POWER CONNECTOR: 4 Pin, with Friction lock, 20‐24 AWG MOLEX 430250400 430300001 Notes: 1. Terminal and Wire current rating must exceed maximum output current. 2. Direct equivalents may be used for any connector parts 3. All cables must be rated 105°C min, equivalent to UL1015 Vox Power Ltd. reserves the right to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice. Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product. For other information relating to the use of the product please refer to the latest NEVO user manual. Vox Power reserves the right to make changes without notice to any of its products. Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vox Power. VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS. IN PARTICULAR ALL OTHER WARRANTIES, CONDITION OR TERMS RELATING TO SUITABILITY, FITNESS FOR PURPOSE, MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED. Document DOC6013 rev 02 Vox Power Ltd. Unit 9 Robinhood Business Park Robinhood Road, Ballymount Dublin 22, Ireland Tel: +353 1 426 4930, Fax: +353 1 633 5511, Web: ww.vox‐power.com Distributed By: