Download Kings Fund Bed User guide

Transcript
KINGS FUND
KINGS FUND BED
Nursing Care Bed
Nursing care bed
www.sidhil.com
User Instructions
Thank you for choosing a Kings Fund 2101 Bed. This user manual should be
read carefully before you use your bed as it contains important information
regarding safe operation and maintenance in order to provide long lasting and
reliable service.
Please ensure that you understand all the instructions, if you have any questions
concerning the operation and maintenance of the bed please contact your
supplier who will provide you with expert professional advice.
In line with our policy of continuous improvement we welcome any suggestions
that could lead to product improvement.
Contents
Section Title
1.
Introduction
2.
Parts Identification
3.
Specifications
4.
Operating the Bed
5.
Do’s & Don’ts
6.
Cleaning Procedure
7.
Maintenance
8.
Accessories
9.
Warranty
Page
1
2
3
4
7
8
9
9
10
1. Introduction
Your Kings Fund Bed is a traditional hospital bed for general ward use. It has a
manually adjustable variable height mattress platform, two way tilt system, gas
assisted rising backrest, bed extension and a full width bed stripper. The bed is
designed to support a maximum user weight of up to 180kg (28 stone). The
light oak laminate head and foot ends are fire retardant and easy to remove.
1
2.
Parts Identification
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Head Board
Protective Buffer
Mattress Platform
Backrest Operating Lever
Height Adjustment Pedal
Base Chassis
Central Locking Castor
Brake Pedal
Tilt Handle
Bed Stripper
Tilt Handle
Foot Board
Bed Extension Handwheel
Rising Backrest
14
13
12
1
2
11
3
4
10
9
5
6
7
2
8
3. Specification
Overall Length
2210 mm
Overall Width
1000 mm
Maximum Mattress Platform Height
810 mm
(to the top of the mattress platform)
Minimum Mattress Platform Height
440 mm
(to the top of the mattress platform)
Maximum Overall Height
1590 mm (62.5”)
Minimum Overall Height
1220 mm (48”)
Castor Size
125 mm (5”)
Maximum User Weight
180kgs (28 stone)
Minimum Under-Bed Clearance
155 mm (6”)
Mattress Extension
185 mm (7”)
3
4. Operating the Bed
Height Adjustment
Raising the bed :
Using the height adjustment pedal situated half way along the base chassis,
labelled ‘raise’, depress the pedal with a pumping action. This will raise the bed
to the desired height.
Lowering the bed:
Pressing the opposite end of the height adjustment pedal, labelled ’lower’, will
lower the bed.
Lowers bed
Raises bed
Mattress Platform Tilt
Head Down Tilt:
Firmly support the bed and raise the right hand tilt handle, situated at the foot end
of the mattress platform. While holding the handle lift the mattress frame up to
a maximum of 12º in 2º increments to the desired level of tilt. Releasing the
handle will lock the bed in the required position.
Foot Down Tilt:
Firmly support the bed and raise both tilt handles, situated at the footend of the
mattress platform. While holding both handles lower the footend to a maximum
of 6º in 2º increments. Releasing the handle will lock the bed in the required
position.
4
To Level the Bed:
Firmly support the bed and raise the right hand tilt handle, situated at the footend
of the mattress platform, while holding the handle raise or lower the footend
until it is level.
When operating the tilt function always ensure the lock pin has engaged after the
handle is released.
Braking and Steering
There are two linked brake pedals at the foot end of the bed which control all
the castors simultaneously.
•When the pedal is in the ‘steer’
position it locks one castor on the bed
so that it cannot swivel. This allows the
bed to be steered when being pushed
from the head end of the bed.
•When the pedal is in the ‘free’
position no castors are locked, allowing
all to swivel freely.
•When the pedal is in the ‘brake’
position three castors are locked and
the bed then cannot move.
5
Raising and Lowering the Backrest
Raising:
Lift the backrest operating lever on the
mattress platform. While holding the
lever lift the backrest to the desired
angle. Note: The heavier the patient
the harder it will be to lift the backrest.
Lowering:
Lift the backrest operating lever and
push the backrest down to the desired
position. Note: The backrest may
drop under it’s own weight when the
lever is lifted, depending on the weight
of the patient.
Backrest operating lever
Bed Extension
To extend:
Unscrew both handwheels situated at
the footend of the mattress frame and
pull out the extension with both hands.
Re-tighten the handwheels to lock the
extension in place.
To return to standard length:
Unscrew both handwheels and push Handwheel
the extension back into the normal
position. Secure in place by tightening
the handwheels.
6
5. Do’s & Don’ts
Do ensure you read these instructions and fully understand them before setting
up or using the bed.
Do ensure the bed is cleaned on a regular basis.
Do ensure the bed is inspected on a regular basis (minimum once yearly service).
Do ensure the lock pin has re-engaged after tilting the mattress platform.
Do Not exceed the beds safe working load of 180kg (28 stone).
Do Not use the rising backrest feature to lift the occupant.
Do Not store any items under the bed.
Do Not allow children to play with or under the bed.
Do Not allow any part of the bed or mattress to come into contact with any
naked flame or excessive heat sources.
7
6.
Cleaning Procedure
Biocote:
Your bed comes with an antibacterial additive incorporated into the
powder coated metalwork. Biocote™ inhibits the growth of bacteria on the
surface of the bed frame. It is effective against a wide range of both gram
positive and negative bacteria as well as fungi. Examples of bacteria that
Biocote™ is resistant to include:
Bacillus Subtilis
Escerichia Coli 0157
Salmonella Enteritides
Staphylococcus Aureus (MRSA)
Streptococcus Faecalis
Listeria Monocytogenes
Biocote™ is an aid to keeping your bed infection free but it does not
substitute the need for the bed to be cleaned at regular intervals.
Cleaning:
All surfaces to be wiped down with a soft cloth moistened with a mild
detergent (or the hospital’s recommended cleaning solution) and diluted in
hot water. Extra care should be taken around areas where excess dirt or
dust may gather. Rinse down with clean water and dry off with a paper
towel.
If any infectious material(s) have been in contact with the bed or it has been
used by a patient with a known infection, the above procedure should be
followed by an additional clean with NaDCC (Presept, Actichlor) at 10,000
PPM of Chlorine (or instructions as prescribed by manufacturer). Rinse and
dry again.
Always ensure that cleaned parts are allowed to dry before putting the
mattress back in place.
8
7.
Maintenance
The Kings Fund Bed is designed to require very little maintenance, however if
there are any signs of damage, or the bed is not performing as it should, then
please contact your supplier for further assistance. Any maintenance should
only be carried out by suitably qualified personnel.
Periodically check to ensure that all fixings including nuts and bolts, are tight and
that none are missing. Check that all cables are in good condition and not
excessively kinked. Sidhil recommends these checks be carried out annually.
If the bed does not operate:
• Check that the bed is free of any obstacles.
• Check that the maximum load has not been exceeded.
• Check that the bed has not reached it’s minimum or maximum height.
• Check that the pedal used to raise and lower the bed is free of any obsatcles.
8. Accessories
Code
2100/T/PEDAL
1292/6/LP
1210/DP
Description
Dual sided pedal
Lifting pole, strap and handle
Transfusion pole with clamp
For the full range of side rails, side rail pads and mattresses please speak to the
Sidhil Customer Service Team. (Contact details can be found on the back of
this booklet)
9
9.
Warranty
Sidhil Ltd guarantees this product is free from defects in material and workmanship under normal use for
3 years (1 year full parts and labour, 2 further years parts only) from the date of purchase from Sidhil Ltd
and its subsidiary companies or its authorised dealers. All implied warranties, including but not limited to
those implied warranties of fitness and merchantability, are limited in the total duration of three years from
date of purchase. Proof of purchase must be presented with any claim. Except as provided herein, Sidhil
Ltd, product warranty does not cover damage caused by misuse or abuse, accident, the attachment of any
unauthorised accessory, alteration to the product, or any other conditions whatsoever that are beyond the
control of Sidhil Ltd. Sidhil Ltd and its subsidiary companies shall have no liability or responsibility to
customer or any other person or entity with respect to any liability, loss or damage caused directly or
indirectly by use or performance of the product or arising out of any breach of this warranty, including but
not limited to any damages resulting from inconvenience, loss of time, property, revenue, or profit or any
indirect, special, incidental or consequential damages, even if Sidhil Ltd or their subsidiary companies or
authorised dealers has been advised of the possibility of such damages.
In the event of a product defect during the warranty period you should contact Sidhil Ltd or their
authorised dealer who will at its option unless otherwise provided by law; a) correct the defect by product
repair without charge for parts and labour b) replace the product with one of the same or similar design
or c) refund the purchase price. All replaced parts and products on which refund is made become the
property of Sidhil Ltd. New or reconditioned parts and products may be used in the performance of
warranty service. Repaired or replaced parts and products are warranted for the remainder of the original
warranty period. You will be charged for repair or replacement of the product made after the expiration
of the warranty period.
This warranty does not cover; a) damage or failure by or attributes to acts of God, abuse, accident, misuse,
improper or abnormal usage, failure to follow instructions, improper installation or maintenance,
alterations, lightning or other incidence of excess voltage or current, b) any repairs other than those
provided by a Sidhil Ltd authorised technician, c) consumables such as fuses, d) cosmetic damage, e)
transportation, shipping or insurance costs or f) costs of product removal, installation setup service
adjustment or re-installation.
This limited three year warranty gives you specific legal rights and you may also have other rights.
Sidhil Ltd cannot be held responsible for any injury or incident which relates to the use of the Sidhil
2101Kings Fund bed in conjunction with accessories manufactured by companies other than Sidhil Ltd.
All products carry the CE mark in accordance with EC Directive on Medical Devices (93/42/EEC). Sidhil
has a policy of continual product improvement and reserves the right to amend specifications covered in
this brochure.
No part of this brochure may be reproduced without the written approval of Sidhil Ltd.
10
Tel: 01422 233000 Fax: 01422 233010
Email: [email protected] www.sidhil.com
Sidhil Business Park, Holmfield, Halifax, HX2 9TN
A member of the Siddall & Hilton Ltd. Group of Companies
(93/42/EEC)
INSTRUC/2101 REV3