Manual of Barrier (Curtain) Sensor
Manual of Barrier (Curtain) Sensor
BS-200RC / BS-400RC / BS-600RC / BS-800RC
BS-200RC: 2 Beams - 57 cm long.
BS- X 00RC- Y
BS-400RC: 4 Beams - 105 cm long.
X =2 or 4 or 6 or 8 beams
BS-600RC: 6 Beams - 153 cm long.
Y =B or W
Standard Installation:
BS-800RC: 8 Beams - 201 cm long.
SCS
2
SCS
1
Mounting Bracket
8 meter
B: Black finish housing
W: White finish housing
Applications:
Indoor / Outdoor perimeter security system
Window, Door. When the mounting space is limited
WALL
Internal / External protection / Terrace / Sliding door
WALL
WALL
Aluminum housing / PC Resin anti-UV cover / ABS
Internal View:
ABS-Side Upper Cap
PC Resin Cover
Tamper Switch
Terminal Block
(Optional)
Aluminum Housing
ABS-Side Bottom Casing
Power LED Indicator
(Green)
VR1: For tx power adjustment
VR1
Tx
Beam alignment LED Indicator
(Red)
SW1Power LED Indicator Response Time Slide Switch
(Green)
JP1
JP2
Buzzer
Rx
JP1: Buzzer alarm(for beam alignment)
Remove JP1: cancel the function after beam aligned properly
JP2 Jumper closed: 1 beam broken alarm (2 sec.) function existed.
JP2 Jumper opened: 1 beam broken alarm (2 sec.) function removed.
Sensing range V.S. Sunlight
Sunlight(Lux)
< 30,000
< 40,000
< 50,000
< 60,000
< 70,000
< 80,000
Terminal block connection.
side cap.
Alarm: Break one or two adjacent beams.
Anti-tamper circuit triggers alarm if power is cut or
Tx power adjustment: By VR1(ON Tx's side cap).
end cap is removed.
Sensing range:8 meters (26 ft.) -- outdoor
Slim aluminum housing, anti high-low temperature /
Rubber ring
Mounting Bracket
Sensing Range
8meters
7meters
6meters
5meters
4meters
3meters
SCS
SCS
Features:
16 meters (52 ft.) -- indoor Max.
fog / rains.
N.O./N.C./Common relay output.
2 or 4 / 6 / 8 separate photoelectric beam sensors.
Mounting hardware included.
Programmable trigger on simultaneous breaking of
No synchronizing wires required.
any single / 2 adjacent beams or 2 adjacent beams
Led alignment indicator.
broken only -- selected by JP2 on Rx's side cap
Tamper switch.
Specifications:
Sensing range
8 meters (26 feet) max.-outdoor / 16 meters (52 feet) max.-indoor
Input Voltage
10-24VDC
Detection method
Break one beam or two adjacent beams
(1) 1 beam: 2 seconds alarm
(2) 2 adjacent beams: immediately
***1 beam broken alarm trigger function can be removed;
See (JP2) which located at Rx's side cap;
(JP2) Jumper closed: 1 beam broken alarm (2 sec.) function existed.
(JP2) Jumper opened: 1 beam broken alarm (2 sec.) function removed.
Signal output
Normal open / Normal close / Common relay output
Response Time (Rx)
50/100/150/200 ms (selectable - by SW1 slide switch-Rx)
1A/120VAC ; 1A/24VDC
Contact rating
Tx Power Adjustment (by VR1)
(a) when turn clockwise: become stronger
(b) when turn counter-clockwise: become normal
Wiring Connection
Terminal block (See page 4)
Power Led indicator
Green Led (On both Tx/Rx unit)
Led indicator
for Beam alignment
Red Led (On Rx unit)
On : when beam is broken ; Off : when beam is aligned properly
On : powered
Off : no power
(a)On : when sensor is connected with DC power & before beam
Buzzer Alarm
alignment is done.
(for beam alignment)
(b)Off : when beam aligned properly ; automatically.
Black jumper1(JP1)(ON Rx)unit
***This function can be cancelled by JP1 removed***
P4
Tamper Switch
4 pcs/each set ; 2 on both sides of Tx/2 on both side of Rx
Operating Temp
-45
Dimensions
Humidity
W: 35 mm / H: 30 mm / L: see following
70%
~55
(-49
~131 )
P1
Manual of Barrier (Curtain) Sensor
Manual of Barrier (Curtain) Sensor
Consumption current
One beam broken continued 2 senconds alarm triggered Cancelled.
("JP2" jumper opened)
Conditions
A
Beam Aligned
Beam Broken
BS-200RC
BS-400RC
VR1 (On Tx Side Cap)
Response Time
BS-600RC
BS-800RC
S1
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
45mA 32mA 55mA 35mA 65mA 38mA 75mA 42mA
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
45mA 40mA 55mA 43mA 65mA 45mA 75mA 48mA
J2
VR1
Broken one beam
Response time: 2 sec
pb
Broken two adjacent beam
Response time: 0.5 sec
Normal
TP TP GND V+
Strong
J1
VR1
One beam broken continued 2 senconds alarm triggered Existed.
("JP2" jumper closed)
Conditions
B
Beam Aligned
Beam Broken
BS-200RC
BS-400RC
Response Time Adjustment (SW1-Rx)
BS-600RC
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
45mA 38mA 55mA 40mA 65mA 43mA 75mA 45mA
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
45mA 45mA 55mA 48mA 65mA 52mA 75mA 55mA
SW1
SW1
SW1
SW1
ON
ON
ON
ON
1
2
50ms
Applications
Typical Installations
BS-800RC
1
2
100ms
1
2
150ms
1
1
200ms
Windows
(Internal / External)
TX
Length
Dimensions
2
TX
Top View
RX
TX
Item
35mm
(Width)
RX
Length
In-Correct
RX
Side View
TX
In-Correct
RX
30mm
(Height)
TX
Windows
Terraces
(Sliding Door)
TX
Length (cm)
BS-200RC
2
57
BS-400RC
4
105
BS-600RC
6
153
BS-800RC
8
201
RX
RX
Correct
TX
Rx D
Suggestion of installation
Response Time Slide Switch - SW1
P-073 V7
E
JP1
SW1
Terminal
Blocks
ON
1
JP1
J2
Internal
Protections
A
P-073 V7
C
B
J2
VR1
TX
1
2
1
2
1
2
1
2
100ms 150ms 200ms
JP2
Tx
Sunlight
Correct
ON
When Jumper closed: One beam broken alarm (2 sec.)function existed.
When Jumper opened: One beam broken alarm (2 sec.)function removed.
(JP1) Jumper When Jumper closed: Buzzer alarm for beam alignment function existed.
When Jumper opened: Buzzer alarm for beam alignment function removed.
Terminal
Blocks
In-Correct
TX
RX
SW1
ON
(JP2)Jumper
But the best installation will be that the wires
running out on the end.
Terminal
Blocks
SW1
ON
JP2
Right side cap
Left side cap
SW1
ON
TP TP GND V+ NO COM NC
J1
If the wires needs to be coming from the
top sides; please seal the opening with
silicon glue to prevent the water from leaking in.
SW1
50ms
2
pb
4
External
Protections
Beams
Length
Correct
3
Door
Gate
Correct
RX
RX
1
3
2
Installation Notes
TX
2
pb
RX
TP TP GND V+
J1
P2
Left side cap
Right side cap
A: Tamper Switch
B: Tamper Switch
C: VR1 Potentiometer for Tx power
adjustment
D: Tamper Switch
E: Tamper Switch
P3