Function
Range
Resolution
Frequency
5.000Hz
50.00Hz
500.0Hz
5.000kHz
50.00kHz
500.0kHz
5.000MHz
0.001Hz
0.01Hz
0.1Hz
0.001kHz
0.01kHz
0.1kHz
0.001MHz
Accuracy
(1.5% reading + 5 digits)
(1.2% reading + 3 digits)
(1.5% reading + 4 digits)
Sensitivity: >0.5V rms min.  1MHz; >3V rms > 1MHz
NOTE:
o
o
o
o
Accuracy is stated at 65 F to 83 F (18 C to 28 C) and less than 75% RH.
Diode Test
Continuity Check
Temperature Sensor
Input Impedance
AC Response
ACV Bandwidth
Display
Overrange indication
Auto Power Off
Polarity
Measurement Rate
Test current of 0.3mA typical, open circuit voltage 1.5V DC typical
Audible signal will sound if the resistance is less than 150 (approx.), test
current <0.3mA
Requires type K thermocouple
7.8MΩ
Average responding
50Hz to 400Hz
4,000 count liquid crystal
“OL” is displayed
30 minutes (approximately)
Automatic (no indication for positive); Minus (-) sign for negative
2 times per second, nominal
Low Battery Indication
Battery
Fuses
“
” is displayed if battery voltage drops below operating voltage
Two AAA batteries
mA, µA ranges; 0.5A/250V ceramic fast blow
A range; 10A/250V ceramic fast blow
Operating Temperature 41F to 104F (5C to 40C)
Storage Temperature
-4F to 140F (-20C to 60C)
Operating Humidity
Max 80% up to 87F (31C) decreasing linearly to 50% at 104F (40C)
Storage Humidity
<80%
Operating Altitude
7000ft. (2000meters) maximum.
Weight
0.5lb (225g) (includes holster).
Size
5.31” x 2.67” x 1.7” (135 x 68 x 43mm)
Safety
This meter is intended for indoor use and protected, against the users, by
double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to
CAT III 600V; Pollution Degree 2. The meter also meets UL 61010-1,
Second Edition (2004), CAN/CSA C22.2 No. 61010-1, Second Edition
(2004), and UL 61010B-2-031, First Edition (2003)
Approvals
CE, ETL