FXCPU Structured Programming Manual
2 Devices in Detail
[Device & Common]
2.7 High Speed Counter [C]
1
General-purpose inputs X000 to X007 (X003) are used for high speed counter inputs. An encoder*1 adopting
the output type shown in the table below can be connected depending on the connected terminal.
Encoders adopting the voltage output type and absolute encoders cannot be connected to high speed
counter inputs.
→ For the wiring, refer to the manual (Hardware Edition) of the PLC main unit.
FX3U-4HSX-ADP*2
2
Devices in
Detail
Output type which can be directly connected to input terminal of
Open collector transistor output type compatible with 24 VDC
main unit
Output type which can be directly connected to input terminal of
Device Outline
4. Cautions on counterpart equipment connected to high speed counter inputs
Differential line driver output type (Output voltage: 5 VDC or less)
A rotary encoder adopting the output type shown above may not operate correctly depending on the
electrical compatibility. Check the specifications before connecting an encoder.