Chapter 3: Configuring and Mapping I/O Name – Give the point a meaningful name. Up to 20 characters can be entered in this field. Valid characters are the letters A-Z, the numbers 0-9, and the characters . (period), / (forward slash), _ (underscore), @ (at symbol), and $ (dollar sign). Is Signed – Flag that allows negative raw and engineering values. 1 = True (Yes); 0 = False (No). Low Raw – Minimum expected raw value for the point; the value as directly read from the device without any scaling, or conversion. Enter a value between 0 and 32767*. Low Eng – Minimum desired scaled (or converted) engineering value for the input. This value corresponds to the Low Raw value defined above and is used for display and reporting purposes. High Raw – Maximum expected raw value for the point; the value as directly read from the device without any scaling, or conversion. Enter a value between 0 and 32767*. High Eng – Maximum desired scaled (or converted) engineering value for the input. This value corresponds to the High Raw value defined above and is used for display and reporting purposes. Delta – Minimum change to be reported (in engineering units). A change in the value of this point will only be reported if the change is equal to or greater than Delta. Units – Units of measurement for this point (e.g., feet or gallons). Description – Brief description of the point. Up to 40 characters can be entered in this field. Valid characters are the letters A-Z, the numbers 0-9, and the characters . (period), / (forward slash), _ (underscore), @ (at symbol), and $ (dollar sign). 4. When you are finished configuring DFS module I/O, you can transfer the configurations to the PLC by choosing Install from the File menu. Note that this only installs the I/O configurations. Ladders and screens are installed using a separate process. Observe the PLC033’s status LED. As it processes the configurations, the blinking pattern will be 3 quick flashes followed by a pause. The status LED will then turn off for a few seconds. When the installation is complete, the status LED will return to its normal blinking pattern (slowly turns on and then off). C ONFIGURE M ODBUS I/O (PLC & RDP) One RS-232 master or slave device can be added to the PLC or RDP’s COM1 port. There is no limit on slave devices when using the COM1 port in RS-485 mode. Several RS-485 devices can be daisy chained together, but be aware that each device added will affect the polling rate. The RDP’s COM2 port can interface with one RS-232 master or slave device. Usually, this device is a radio through which the RDP polls remote I/O. However, it is also possible to use the COM2 serial port as an interface to a single RS232 master or slave device. A DD A N EW M ODBUS D EVICE 1. Select the desired Modbus driver on the tree. Note that MODBUS_SERIAL_0 is used for a PLC033 or RDP; MODBUS_SERIAL_1 is only used for an RDP. 2. Right click and select New Device from the pop-up menu. PMT User Manual 46