Download AVIIVA EM4 BA8 User Manual

Transcript
AVIIVA® EM4 BA8
Ext Trig with Exposure time set in the camera
This mode requires an external trigger ( via CC1) but the exposure time is the one defined in the Camera.
If the line period of the Trig signal provided to the camera is lower than the exposure time set in
the camera, the “short trig pulses” will be ignored : The exposure set in the camera defines the
minimum line period possible.
td
th
tint
tper
CC1
EXPOSURE N+1
EXPOSURE N
READOUT N-1
READOUT N
tdr
The Minimum Line period taken in account by the
Camera is the maximum between :
MinLP = Exposure time + td + tdr. And LPmin
Label
Min
tint
1
Typical
Max
Unit
tper
MinLP
-
-
µsec
th
0,3
-
-
µsec
td
-
0,25
-
µsec
tdr
-
1,32
-
µsec
µsec
Ext Trig Full Exposure time available
This mode requires an external trigger ( via CC1). The exposure time is the maximum possible value
between two Tri pulses.
In this mode, the exposure time set in the camera is ignored.
Avoid this mode if your trigger is not stable (variable line period) : The exposure of each line could
then be different. If the period of the trig signal is less than the readout time, the Camera won’t
send any signal.
td
CC1
th
tint = tper
EXPOSURE N
Min
Typical
Max
Unit
tper/tper
LPmin
-
-
µsec
th
0,3
-
-
µsec
td
-
0,95
-
µsec
tdr
-
1,32
-
µsec
EXPOSURE N+1
READOUT N-1
25
Label
READOUT N
e2v semiconductors SAS 2012
1013bisA - AVIIVA EM4 BA8 02/12
tdr