Download XFR600-2 Operating Manual
Transcript
Operation Front Panel LEDs Front Panel LEDs The status LEDs on the front panel give an instant indication to the status of the power supply. LED Description REM Unit is operating under remote control. Remote settings apply. SRQ Unit is requesting service S/D Unit is in shutdown due to tripped protection mechanism, command, or interlock In addition, the XFR and XHR series power supplies have the following additional indicators. Release 2.1 LED Description ERR Unit has encountered an error ADR Unit is receiving a command OVP Unit is shutdown due to a hardware over-voltage condition. OTP Unit is shutdown due to an over-temperature condition. ACF Unit is shutdown due to an AC input failure condition (AC line may be high or low.) POL Used to indicate the AUX A status condition is true. FLT Used to indicate the AUX B status condition is true. 47